How ESD Control Differs ESD control systems are en-


gineered to dissipate static elec- tricity safely and consistently to ground. Rather than simply re- ducing the likelihood that a charge will develop, the system provides a way to manage that charge once it exists. This level of control is par-


ticularly important in electronics manufacturing, cleanrooms and laboratories, aerospace and de- fense applications, and medical device production, where small electrostatic events can damage sensitive products. ESD flooring is also used as


part of static-control programs designed around recognized in- dustry requirements such as ANSI/ESD S20.20. The key distinction is there-


fore one of function. Anti-static materials mitigate static genera- tion, while ESD control systems are designed to provide protec- tion by creating a controlled path for dissipation.


The Risk of Latent Damage The consequences of inade-


quate ESD protection are not al- ways immediately visible. A sig- nificant discharge may cause an obvious component failure, but lower-level events can also cre- ate latent defects. A component may initially pass inspection and operate normally before failing later in the field. These failures can lead to


rework, warranty claims, prod- uct recalls and higher operating costs. Because the connection to an earlier electrostatic event may not be obvious, the underly- ing source of the problem can also be difficult to diagnose. Facilities handling ESD-


sensitive devices therefore need to consider static control as part of the overall manufacturing en- vironment rather than as an iso- lated flooring decision.


Flooring as Part of the ESD System


An effective ESD floor must


maintain appropriate electrical characteristics while supporting the practical requirements of the facility. StaticStop flooring sys- tems are designed to maintain controlled electrical resistance over time without requiring wax- ing or buffing for ESD perform- ance. Available systems include bonded flooring as well as modu- lar, free-floating interlocking tiles, giving facilities options based on installation require- ments and operating conditions. Modular systems can be par-


ticularly useful when an existing production area must be converted for ESD-sensitive work without extensive disruption. Individual areas can be installed or expanded as requirements change, while


For Superior Inspection and Metrology Performance. – Metrology-grade accuracy with multi-award-winning Multi-Reflection Suppression® (MRS®) technology that mitigates reflection based distortions from shiny surfaces.


– High-Resolution and high-speed sensor options. – Faster and smarter with AI-Enabled AutoProgram™


, AutoTeach™ , AutoDefine™ streamline processes – All part of the Nordson Intelligence Ecosystem. – Multi-functionality for AOI, SPI and capturing coordinate measurements (CMM) in-line, in seconds with NordsonCMM. Nordson Sight Soſtware – Fast, Intuitive and Scalable SPC Solution Save Time. Save Expense. Improve Yields.


nordson.com/testinspect | +1 760.918.8471 Copyright © Nordson Corporation. All rights reserved.


and AutoTune™ to minimize operation and AOI SPI CMM


ADVANCED High Speed


MRS Sensors Resolution and High


www.us - tech.com


permanent systems remain an op- tion for facilities planning a more traditional installation. Regardless of the flooring


type selected, performance should be considered as part of the com- plete ESD control program, includ- ing personnel, equipment, ground- ing and ongoing verification. The correct solution ulti-


mately depends on the risks present in the facility. Where static electricity is


primarily an inconvenience, an anti-static material may provide sufficient mitigation. When sen-


sitive electronics are being man- ufactured, assembled, tested or handled, however, facilities need a system specifically designed to control electrostatic charge. That distinction becomes


particularly important where compliance with established ESD requirements is necessary. Selecting appropriate floor-


ing is therefore not simply a mat- ter of reducing occasional shocks or static buildup. It is part of pro- tecting products throughout manufacturing and helping pre- vent both immediate failures and


Page 53 Anti-Static vs. ESD Control: Understanding the Difference


less obvious latent defects. For electronics manufactur-


ers, effective ESD control de- pends on managing static rather than merely reducing it. A prop- erly designed system provides a predictable path for charge dissi- pation and helps protect equip- ment, components and finished products throughout the produc- tion process. Contact: StaticStop, 33


Wales Avenue, Suite F, Avon, MA 02322 % 508-583-3200 E-mail: info@selectech.com Web: www.selectech.com r


Blazing Speed. Unmatched Precision. SQ5000™


Pro Multi-Function 3D AOI, SPI & CMM


See at SEMICON West, Booth 5844








Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84