Mike Elms, Sales and Marketing Director at CENTIEL Ltd, looks at how improving operational efficiencies of UPS systems reduces energy consumption.
Availability of power is essential in today’s ever-increasing digital world and IT business critical environments. As well as the obvious interruption to power to the critical load, power outages can also potentially cause physical damage to equipment and essential data can become corrupted or inaccessible, leading to issues keeping the business going long after the lights have come back on. Concerningly, it has been reported that power outages in the UK are on the increase.
“Within a resilient system offering redundant parallel UPS units the individual load capacity is often 20-30%”
The solution is to implement a reliable uninterruptible power supply (UPS) and in today’s increasingly competitive environment, maintaining operational efficiency is essential to keep running costs down.
Over the last 10-15 years the biggest driver for UPS development has been efficiency. By utilising a more efficient UPS unit and units within larger resilient systems, this minimises OPEX, reduces carbon footprint attracting government funded tax incentives and aids Corporate Social Responsibility (CSR). So, what are the main considerations when considering an efficient UPS solution?
Firstly, all manufacturers will claim very impressive efficiency figures for their UPS units, initially the marketing “glossies” focussed on a maximum efficiency value with the UPS operating at 100% capacity, although in reality, a UPS unit/system never operates at such a figure. A typical single UPS unit may operate around 50-70%, although even this is generous. However, within a resilient system offering redundant parallel UPS units the individual load capacity is often much lower, 20- 30% is common. Therefore, it is important to look at the efficiency figures at the range in which the UPS will be operating in.
Transformerless UPS units greatly aided this drive with their flat efficiency curve down to 25% capacity but even these tailed off quite significantly below this figure. The latest generation of UPS system are now achieving 95.5% efficiency at load capacities of only 10%. An amazing success when compared with legacy systems of only a few years ago. A good source of information is the Energy Technology List, a completely independent list which continues to raise the standards of UPS efficiency, look to see if your UPS is listed.
32 | TOMORROW’S FM
An inefficient UPS system generates heat, increasing your UPS efficiency decreases the cooling requirement to remove this heat. Replacing legacy UPS systems has become a powerful argument when comparing the potential OPEX saving with installing the latest more efficient UPS units. One such recent replacement was on a traditional multiple unit system, offering N+1 resilience, comprising of three 250 kVA UPS units running in parallel.
The site load averaged only 200kVA. With all UPS units sharing this load, each individual unit was supporting 67KVA and therefore operating at 27% of its capacity. As the units were some 15+ years old and of the legacy transformer-based design, the overall electrical efficiencies were measured at only 80-85% and you have to add the heat losses which were significant.
By calculation the savings in OPEX was an amazing £62,000 per year, a CO2 reduction over five years of > 850 tonnes with a carbon neutral offset of some 1,350 trees.
So, what do we need to look at when considering a UPS system with regard to operating costs? The first step is to find a system with the highest efficiency for online operation.
“Replacing legacy UPS systems has become a powerful argument
when comparing the potential OPEX saving with installing the latest more efficient UPS units”
As systems are not run at 100% load all the time, so check the UPS unit reaches peak efficiency when operating at your own sites expected load. Select a technology that offers a flatter efficiency curve across the widest load range. CENTIEL’s UPS technology is 95.5% efficient even at 10% load.
So, let’s get back to our 3 x 250KVA example and its replacement system. With a new modular system based on CENTIEL’s Distributed Active Redundant Architecture (DARA), with twelve 50kVA modules installed, each module would be at 33%, still quite a low figure but the solution was also dictated by the existing electrical infrastructure available. At these values of load the Centiel system was at 96.75% efficient. Over five years, the calculated OPEX savings are greater than £300,000.
www.centiel.co.uk twitter.com/TomorrowsFM
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74