42 Air Monitoring Steam Heated Gas Sampling Probe


The heated gas sampling probe JES 301G from JCT Analysentechnik (Austria) is designed for continuous sampling in processes with high dust content. As the heating source is steam, the probe can also be used in ATEX Zone 1 or 2 where electrical connections may cause problems. JCT´s heated hose series JH can be easily connected directly to the JES 301G. Gas Sample Probes incorporate a calibration and / or back purge port are also as an option available.


The operating temperature of max. 200°C is regulated by the steam pressure. A sample ceramic filter element with a filter porosity of 2 micron and the filtration from outside to the inside ensure that the gas passes the heated hose free of dust particles. The filter can be replaced easily without any tools while the heated hose stays connected.


The heated gas sampling probe JES 301G is extremely robust to provide many years of operation in harsh environment. Typical process or CEM applications can be found in chemical and petrochemical industry.


A broad range of different materials for filter elements, In-situ probe tubes and large In-situ-pre filters make the JES 301G versatile in application. 25916pr@reply-direct.com


For More Info, email: Simplifying Laser Diode Operation For OEM Gas Sensing Solutions


Incorporating all necessary laser driver and temperature control electronics with the Laser Diode is a massively simplifying and freeing exercise, especially for OEMs that employ Tunable Diode Laser Absorption Spectroscopy (TDLAS). Eblana Photonics (Ireland) have now produced a versatile & flexible product for this purpose – The DX1-Sensing.


Leveraging Eblana’s Discrete Mode (DM) single-line laser technology, optimised for industrial gas and air quality monitoring, The DX1-Sensing incorporates the laser diode with all necessary electronics to drive the laser and temperature controller fully, functionality necessitated by TDLAS, all housed in a compact yet highly robust enclosure.


By removing the onus of the OEM to design and manufacture all laser control electronics, Eblana Photonics have


simplified the entire process, whilst keeping costs low. The DX1-Sensing is operated by a single 5V supply, and allows for direct modulation and temperature control – perfect for integration with custom electronics. The DX1-Sensing is specifically designed to be incorporated with all of Eblana’s existing gas sensing lines: O2, CH4, NH3, CO2, HCl, H2O, CO, Rb.


For More Info, email: 26947pr@reply-direct.com Improved Ambient Air Gas Analysers


The Ecotech (Australia) Serinus ambient air gas analysers continue to evolve with improved appearance, functionality and performance. Offering improvements in communication, programmability and useability, Ecotech's latest upgrade to the Serinus analysers provides a solution that is second to none for use in ambient air monitoring.


The Serinus analysers are U.S. EPA Equivalent or Reference Methods and EN approved. They are designed especially for the measurement of criteria


pollutants including O3, CO, NO/NO2/NOX and SO2. Additional instruments in the range for the measurement of NH3, H2S, TRS and TS are also available.


The Serinus range features enhanced communication which now includes RS232, USB and Bluetooth as standard plus optional TCP/IP ethernet. Bluetooth connectivity combined with the “Ecotech Serinus Remote” Android App (available from the Google Play store) makes it even easier to program, maintain, download and email data without touching the instrument.


Completing our communications package is a wide range of protocols including Modbus, Bavarian and Ecotech’s own advanced protocol which provides access to over 200 measurement and diagnostic parameters.


Combining these analysers into an ambient monitoring station and using Ecotech’s Airodis Data collection, validation and reporting software to manage data helps our customers achieve high data capture rates, minimise maintenance and achieve their air quality monitoring objectives.


For More Info, email: 26107pr@reply-direct.com


The Excellence for Ambient Air Analysis on Benzene and VOCs Using a unique mix


of gas chromatograph technology and a photoionisation detector (PID), the VOC 72M from Environnement S.A (France) has a


Optimised indoor air quality


superior performance standard equal to laboratory chromatographs. Robust and low maintenance (no PID lamp cleaning), with wide voltage range specifications (90-240V), it is equally suited to fixed or mobile ambient air quality monitoring stations.


Able to provide detection in the ppb range and equipped with an LCD screen, the VOC 72M can be used to sample, analyse and manage data from VOC samples in a simple and completely autonomous mode. The LCD screen easily displays the gas chromatograph peaks directly-on-screen without any need for a laptop or PC. The imperceptible memory effect (10 times lower than required by the standard EN14662-3) allows the calibration of the analyser on a single cycle without an external PC. The column is equipped with an innovative liquid-cooler; the retention times are stable even with a fluctuating temperature.


Indoor air quality monitoring


The wall-mounted or desktop CO2 display measures and records CO2, humidity and temperature simultaneously. Air quality in classrooms, meeting rooms, offices and other environments can be conveniently checked at a glance.


 2, humidity and temperature values  2 indicator    


 


email: 594ad@reply-direct.com IET September / October 2013 www.envirotech-online.com


Finally, the remote diagnosis without opening the hood, the replacement of the trap in less than 2 minutes requiring no adjustment, a PID detector more sensitive, more stable and whose lamp does not need to be cleaned, integrated flow control fittings, the use of only one gas (nitrogen), a 3 levels security system built on, etc. makes this robust and low maintenance instrument the must have for air quality for monitoring networks.


The VOC72M is TÜV certified and complies with the European standard EN14662-3 for the measurement of benzene.


Discover this instrument at Pollutec 2013: HALL: 6, Stand No.: K132


26977pr@reply-direct.com For More Info, email:


State of the Art Online GC for Environmental Monitoring


For direct measurement of VOC’s including Benzene, Toluene, Ethylbenzene, Xylenes


and many other pollutants Baseline (USA) Series 9100 Gas Chromatograph offers the ultimate solution. This state of the art instrument provides a multitude of features including lab quality measurement in an online fully integrated analyser. Using a Photoionisation detector, the 9100 can accurately measure multiple gases into sub ppb ranges.


Key features include powerful integrated software eliminating the need for an external PC, programmable touch screen and USB Interface. Remote control, automatic calibration and internal data storage allow for unattended operation. Other features include LAN connection, analogue outputs, relays, multipoint sampling and a graphical display of current or historic concentrations. The compact design allows for easy transport, desktop use or rack mounting in limited space.


Environmental applications include ambient air networks, emission sources, EPA compliance and fence-line monitoring around industrial and remediation sites. With over four decades of experience, Baseline is well established in the gas measurement market. Other key applications for the 9100 Series include Exposure to Toxic Gases, Impurities in Specialty, Industrial and Beverage Gases as well as Fast C1 to C5 Mud / Well Logging during Oil and Gas Exploration.


26773pr@reply-direct.com For More Info, email:


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68