Portable / Field Testing
27 World Class Air Quality Monitoring Solutions Showcased at European Aerosol Conference
Proven solutions for air quality monitoring, including systems for asbestos testing to NIOSH traceability standards, and compact, environmentally friendly options for particle/aerosol counting and sizing, were on display at the Copley Scientific (UK) stand at the European Aerosol Conference (EAC 2013), 1-6 September, Prague, Czech Republic. Experts from the company were on hand throughout the event to advise on the best technology for specific applications and to meet legislative requirements.
The Model 7400 AD real-time fibre monitor is a compact, field portable unit, suitable for airborne fibres such as asbestos, mineral wool, advanced composites, ceramic and glass. Developed by MSP Corporation, Copley Scientific’s partner in North America, it offers traceability to NIOSH Method 7400 for asbestos testing and delivers up to eight hours of uninterrupted, automatic and fully customisable air safety monitoring. It is suitable for use in manufacturing operations and during asbestos removal.
Also on display was the M1110, a water-based condensation particle counter (WCPC), and the wide range particle spectrometer (WPS). Used in clean rooms, environmental science applications, high purity gas systems and other air sampling applications, the M1110 WCPC employs innovative single-flow mixing technology to give superior counting at high particle concentrations and is valued for its environmental credentials – no butanol used as a working fluid and highly efficient HEPA filters.
The WPS is ideal for applications that require aerosol sizing and counting and uses an electrical ioniser to neutralise particle charge prior to differential mobility analysis (DMA) rather than a radioactive source. The WPS combines DMA and condensation particle counting with laser light scattering in a single instrument, to deliver a measurement range of 5 nm to 10 microns.
For More Info, email:
26692pr@reply-direct.com New Portable Noise, Sound and Vibration Analysers
Svantek’s (Poland) noise dosimeter SV104, boasts all the capabilities and functions of a full-size dosimeter. Featuring an inbuilt tri-axial accelerometer for vibration shock detection, a revolutionary, and virtually indestructible, MEMS microphone, making it the most technically advanced, as well as the most accurate, robust, and reliable personal dosimeter on the market. It’s the only personal noise dosimeter with audio recording and octave band analysis for hearing protection selection, and has a state-of-the-art high resolution, full-colour OLED screen.
Svanteks power-packed SVAN 971 sound level meter and analyser is equally compact and lightweight, offers audio event recording, detachable pre-amp & microphone, a dosimeter function and a vast time/history logging capability. Perfect for industrial hygiene, short period environmental, and general acoustic noise measurement, it provides broadband results with all required weighting filters, as well as 1/1 octave & 1/3 octave analysis and has a high-contrast colour OLED-type display.
The simple to use SVAN 977 sound and vibration analyser is suitable for workplace health and safety and/or environmental monitoring. Providing standard weighting filters, broadband and incredible time/history logging capabilities. A Micro SD card gives almost unlimited logging capacity, and its Bluetooth interface and Smartphone applications extend its measurement capabilities and a selection of remote methods of communication such as GPRS, Ethernet, WLAN or ZigBee.
For More Info, email:
26679pr@reply-direct.com Compact Photometer for COD Analysis
As Machery-Nagel (Germany) is constantly working on adding new tests and versions to increase the breadth of the PF-3 line, they are pleased to present the newest version of their PF-3. Together with the proven Nanocolor test kits, the PF-3 is a perfect combination for cost-efficient COD analysis.
The COD concentration plays a major role for the assessment of waste water. As a sum parameter for the organic load within waste- water, COD is one of the most important parameters in waste water analysis. Amongst other things, the parameter is used for calculation and control of water purification in sewage plants.
With the new PF- 3 version, Machery-Nagel offers a unique and mobile instrument for convienient COD analysis at low costs. Being able to evaluate even low range COD tests, the PF-3 is the ideal companion for various industrial applications and in-field analysis. The user-friendly and precise Nanocolor test kits allow easy and fast measurements and maximum safety for the user. The contact with any dangerours chemicals is avoided, because the measurement is performed directly in the test tube.
Of course, even with the new version of the compact photometer PF-3, you benefit from convenient handling and comprehensive menu structure, as well as the handy and robust design. The instrument is water proof according to IP 68 and enables reliable performance even under extreme conditions. The unique “Open-Slot” technology allows to measure without cuvette slot cover, thus simplifying and speeding up your processes. Additional features such as an optional 0-measurement storage, multiple power supply options and a bright display add to the power and user friendliness of the PF-3
With the instrument´s USB interface, you can quickly transfer data or update the instrument, supply it with power or charge the (optional) accu-pack. As with all Machery-Nagel photometers, they provide free of charge software packages to administer and manage your data. Using the USB interface, you can also add any additional tests that may be available for your specific version for free.
Thus, Machery-Nagel can address customers´ future needs, enabling you to benefit from all the options of their systems without incurring unnecessary costs.
In the near future, more versions of the PF-3 will come to market, enabling additional applications in different areas and industries.
For More Info, email:
26609pr@reply-direct.com
email:
354ad@reply-direct.com
www.envirotech-online.com IET September / October 2013 email:
353ad@reply-direct.com
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68