ii UK Focus - Portable / Field Testing
24-Hour Noise & Dust Monitoring at City of London Demolition Site
When 24-hour real-time monitoring of noise and dust levels was required by Keltbray, the UK’s leading specialist engineering, construction, decommissioning and environmental services business, the Boundary Guardian from Casella (UK) – global specialist in occupational health and environmental risk management solutions – was considered the best solution for the job.
Altin Lleshi, Safety, Health & Environment Advisor with Keltbray, explains: “We were working on a project at Mitre House in the City of London in close proximity to a private educational institution, where the dust and noise associated with the deconstruction work we were carrying out had to be carefully managed.”
He continues: “This required real time 24-hour monitoring. We chose the Casella Boundary Guardian because it has some new features such as local alarms and emails that inform us when dust or noise limits are exceeded, plus a dedicated website for viewing real time and historical data from the unit.”
“What’s more”, Altin concludes: “The Local Authority Environmental Health Officer welcomed the use of the Boundary Guardian because the versatility of the monitor helped us to achieve full environmental compliance.”
DRM Technic Ltd is one of the leading UK distributors of gas analysis equipment and analysis system spare parts.
We are the UK appointed distributors for: Gas Analysers Fuji Electric
Extractive Gas Analysers MCERTS & TuV Approved Up to 5 gases per analyser Lowest UK costs (i.e. up to 28% less than Siemens)
In-Situ Laser Gas analysers 2 Component In-situ Gas Analyser (HCl, NH3, HCl + H2O, NH3 + H2O, O2, CO, CO2, CH4, CO + CO2)
Gas Conditioning Equipment Buhler GmbH
Gas Sample Probes Heated Sample Lines Gas Coolers Sample Gas Filters NOx Converters Accessories Gas Sample Pumps Gas Analysers New Products
DRM Technic Ltd
Unit 18 Trentham Lakes Technology Park, Trentham Stoke-on-Trent, Staffordshire, ST4 8LJ
Tel: 01782 326 632 Email:
mail@drmtechnic.com Web:
www.drmtechnic.com
email:
362ad@reply-direct.com
Mounted on a pole above the hoarding level, as agreed with the City of London, the Boundary Guardian is easy to operate and requires minimal training.
It is the first simultaneous multi parameter monitor for dust, noise, wind speed and wind direction in the UK from a single manufacturer. Featuring an IEC61672-1 compliant sound level meter, proven dust measurement technology and a maintenance-free wind speed and direction sensor, it provides accurate, reliable data in harsh outdoor environments, and helps to ensure that conditions that are likely to cause adverse health effects are reduced or eradicated.
By accessing a private log-in on dedicated website,
www.dataview247.com, Keltbray engineers are able to extract data and produce reports wherever they are, at any time of day or night. According to Keltbray, which also uses Casella’s CEL 633 real time sound level meter, CEL 490 sound level meter and Microdust Pro dust monitor on other demolition and construction sites, the Boundary Guardian “is proving to be cost effective, extremely accurate, reliable and very easy to use”.
For More Info, email:
26793pr@reply-direct.com Quick Soot Test Protects Diesel Engines
As environmental regulations increase the pressure on engine manufacturers to reduce the levels of soot emitted from diesel engine exhausts, increased soot levels in lubricants are inevitable, and this could have a major effect on engine performance. In response, Quantitech (UK) has launched a new soot-in-oil measurement technology to enable testing laboratories, lorry and bus fleet managers, ship engineers and power station managers to conduct quick tests to ensure optimal lubrication efficiency.
The InfraCal ‘Soot Meter’ a rugged, portable factory-calibrated infrared spectrometer performing an ASTM approved test method which involves two simple steps that can be undertaken by non-technical personnel, producing a result in less than 15 seconds.
Particulate Sampling Kits
Do you undertake Workplace Monitoring? SKC has the kits you need Do you undertake Environmental Monitoring? SKC has the kits you need
Do you expect… - Quality Products - Experience and expertise - Responsive technical support - Customer satisfaction
SKC has everything you need
To place your order or for further information please contact SKC quoting ref: IET0913 SKC Limited, 11 Sunrise Business Park, Higher Shaftesbury Road, Blandford Forum, DT11 8ST Dorset.
Tel: 01258 480188 W:
www.skcltd.com E:
enquiries@skcltd.com email:
334ad@reply-direct.com IET September / October 2013
www.envirotech-online.com
Soot enters the lubricant with exhaust gas in the form of blow-by, or it is deposited on cylinder walls and subsequently scraped off by the rings and deposited into the oil, causing wear on engine components and clogging filters. A number of factors affect the level of soot contamination in the engine; these include injection timing, combustion chamber design, engine type, scavenge efficiency, air cleaner restriction, air/fuel ratio, low compression, excessive idling and lugging.
Quantitech’s Dr Andrew Hobson says “The Soot Meter is an ideal tool for anyone responsible for the efficient running of diesel engines; it is extremely easy to operate and is capable of taking measurements both in the laboratory and in the field.”
For More Info, email:
26540pr@reply-direct.com
www.envirotech-
online.com
Take a look at our website
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68