search.noResults

search.searching

saml.title
dataCollection.invalidEmail
note.createNoteMessage

search.noResults

search.searching

orderForm.title

orderForm.productCode
orderForm.description
orderForm.quantity
orderForm.itemPrice
orderForm.price
orderForm.totalPrice
orderForm.deliveryDetails.billingAddress
orderForm.deliveryDetails.deliveryAddress
orderForm.noItems
00


Health & Safety


Evaluation of an Improved Sample Preparation Method for Quantative Analysis of Very Low Levels of Airborne Polycyclic Aromatic Hydrocarbons for Worker Protection and Health Screening


Polycyclic Aromatic Hydrocarbons (PAHs) are large class of compounds comprising two or more fused aromatic rings. PAHs are naturally occurring in fossil fuels and their derived products and can be formed during incomplete combustion of carbon based fuels. As such they are a by- product of many industrial processes. PAHs vary greatly in size, nature and hazard to human health, some are not classified as toxic, where as others are known carcinogens. The IARC specified 16 as being of particular interest, others have subsequently added this list. In all, over 100 PAHs have been described.


PAHs vary greatly in size, nature and hazard to human health, some are not classified as toxic, where as others are known carcinogens.


Given the risks and potential risks to human health presented by PAHs, many high risk organisations, such as Foundries, Bitumen Works & Smoke Houses routinely monitor workers and their environment for PAH levels. Typically PAHs are trapped using filters (particulate forms) or resins such as XAD2 (gaseous forms) through which work place environmental air is drawn. Filters may be situated in a small device attached to the workers overalls, or from larger units measuring the air in a wider area. Potential problems exist when recovering the PAHs from the filters and preparing the samples for analysis, principally, losses due to PAH volatility are reported for bi- and tri-cyclic PAHs (ISO11338- 2:2003). Therefore, ITGA undertooka study to improve sample recovery and therefore PAH determination when working with low and very low levels of analytes.


Sample Preparation Methodology


Methods for workplace sampling are well described in the literature (NFX43-294 and Method Metropol 011) and result in samples trapped on glass or quartz fibre filters. The filters are preserved and delivered to the analytical laboratory. The whole filter placed into a barcoded vial, 10ml dichloromethane (DCM) is added and the tube placed in an ultrasonic bath at room temperature for 15 minutes to extract the analytes. This operation is repeated once with 10ml of DCM to optimise extraction. Following extraction the sample is concentrated to 1ml using a nitrogen blowing system and then analysed via HPLC coupled to a Fluorescence detector. XAD2 resin tubes may be used as an alternative to fibre filters.


Evaluation of new Sample Preparation Methodology


Author Details: Nicolas Falquet1


,


Gilles d’Esperonnat2 Rob Darrington2


&


1. ITGA, St-Etienne, France. 2. Genevac, Ipswich, UK.


A standard solution containing the US-EPA 16 PAHs (as defined by IARC, 1987) was spiked onto quartz fibre filters or XAD2 resin tubes and allowed to air dry. The filters / tubes were then extracted twice using 7ml DCM and sonnication in the ultrasonic bath for 15 minutes at room temperature. The combined sample (14ml) had a 100µl aliquot removed. This was made up to 1ml with acetonitrile was taken and injected into HPLC-Fluorescence to provide a 100% reference. The remaining DCM had 100µl 2-pentanol added as a solvent keep and was evaporated via centrifugal vacuum evaporation in the Genevac EZ-2 Envi (Figure 1). Temperature and pressure during evaporation were controlled such that the DCM evaporates but the 2-pentanol does not, as previously


47


Figure 1 – Genevac EZ-2 Envi described by Marsico (2006) and Massat et al. (2007).


The samples were then made up to 1ml using acetonitrile and injected into HPLCFluorescence for analysis. Recoveries for all analytes, even the most volatile were in excess of 90% and the fit of the analytical curve to the reference sample was very good, and shown in figure 2 below.


Validation of the Process


Having delivered similar results to the existing method, and being beneficial in the sense of “automation” of the concentration process, statistical validation of the process and equipment was required. Using the above methodology, a solution containing 14 PAH samples was spiked onto quartz fibre filters and also on to XAD2 resin tubes. Filters were spiked at 100ng and 10ng. These were allowed to dry and


www.envirotech-online.com IET March / April 2012


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72