Chromatography 9 Reproducible Protein Molecular Weight, Sizing & Aggregation Studies Through Advanced Bio-SEC


Size exclusion chromatography delivers information on the purity and stability of bio-therapeutic drugs such as monoclonal antibodies. These large biomolecules are highly sensitive to workflow stress that can induce variation in size, formation of dimers and oligomers, or aggregation of monomers.


For accurate determination of molecular weight, size and aggregate presence with highest reproducibility, the new Agilent 1260 Infinity Multi-Detector Bio-SEC solution unites fully bio-inert instrumentation with high-resolution columns, advanced detection, and intuitive, workflow-driven software.


100 % Bio-inert Instrumentation


Based on the proven technology of the 1200 Infinity Series liquid chromatography platform, the 1260 Infinity Multi- Detector Bio-SEC solution handles with ease the challenging solvent conditions commonly used for analysis of proteins and bio-therapeutics. The entire flow path is completely metal-free to ensure reproducible data.


Advanced Light Scattering Detectors


The addition of laser light scattering detection offers the advantage of being able to measure the absolute molecular weight without the need to calibrate the SEC columns with narrow standards. Dynamic light scattering adds the ability to be able to assess molecular size and calculate the hydrodynamic radius, Rh.


The dead volumes between the detectors are kept to a minimum to avoid band broadening effects. The light scattering detector has the smallest flow cell of any instrument commercially available at only 10ul. Separation efficiency is absolutely assured.


Light scattering detection is an important technique being increasingly used to study the aggregation of these biomolecules which can be a major problem, since it can cause immuno-response issues which in turn can result in death or serious injury during patient treatment.


High-Resolution Columns


An extensive range of available Agilent Bio-SEC columns provides excellent resolution.


Workflow-driven Software


The 1260 Infinity Multi-Detector Bio-SEC solution is specifically designed for modern workflows providing everything required to successfully introduce advanced protein analysis to any laboratory. An open access chromatography data system (CDS) offering simple and intuitive interaction ensures anyone can take advantage of the multiple benefits light scattering offers. Analysis wizards take the user stepwise through all of the data to ensure integrity of results. Optimised methods can be implemented which allow single click analysis through advanced algorithms and automatic interrogation of all system parameters.


See How it Works


Learn more about the new Agilent 1260 Infinity Multi-Detector Bio-SEC solution. Watch the video and download brochure as well as Application Notes at www.agilent.com/chem/infinity-bio-sec


29037pr@reply-direct.com 1328ad@reply-direct.com © Agilent Technologies, Inc. 2014


For the analysis of large bio-molecules or biologics, the new Agilent 1260 Infi nity Multi-Detector Bio-SEC solution unites advanced detection, fully bio-inert instrumentation and high-resolution columns, simplifi ed with intuitive software to determine accurate molecular weight, size and aggregate presence with highest reproducibility.


Boost Performance Maximum sensitivity and accuracy through advanced detection


Save Time Reduce Costs


Easy-to-use software simplifi es workfl ow with routine and expert-mode


Highest uptime through reliable, optimized single vendor solution


Agilent 1260 Infinity Multi-Detector Bio-SEC Solution


BIO-SEC


REPRODUCIBLY ADVANCE YOUR


INFINITELY BETTER TECHNOLOGIES Reproducible protein sizing and aggregation studies is one of a wave of innovative Agilent technologies for ensuring your Agilent 1200 Infi nity Series LC stays at the forefront of separation potential.


Learn more www.agilent.com/chem/infi nity-bio-sec


ADVERTORIAL


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56