3.5.1. Electrical resistance MACHINE
No. OF BOILERS
1 IBERITAL INTENZ 2 IBERITAL IB7 NEW IBERITAL
IBERITAL EXPRESSION TWO
1 1 2
GROUPS 1 2
3 2 3
1 2
3 2 3
2 3
3.5.2. Spring-loaded safety valve
In the case of irregular operation in the control of heating elements, the safety valves guarantee the integrity of the boiler, releasing excess pressure and keeping it from going over 0.18 MPa.
The safety valves are manufactured under strict quality control standards and following very demanding technical criteria. Once checked by the manufacturer, they are immediately sealed.
3.5.3. Pressure relief valve (anti-vacuum valve)
This valve, located on the boiler, prevents the depressurization of the boiler interior, keeping liquids from being sucked in through the steam ejectors.
3.5.4. Automatic water fi lling device a) Solenoid valve.
The machine has a level sensor (a stainless steel strip that is in contact with the water inside the boiler). The sensor is connected to a control processing unit (CPU) which permanently indicates the water level. When the level is low, the CPU activates the pump and the solenoid valve, allowing water to be fed in until the sensor indicates that it has reached the optimum level.
3.5.5. Visual level (Optional) a) Level (visualization of max. and min. levels for the boiler water).
The water level can be checked at any time via the water level viewer (22). 3.5.6. Flow control valves a) Expansion valve (crucible for opening to 1.2 MPa /+0.1.)
3.6.- PUMP/MOTOR
a) Lock nut. b) Adjustment screw.
The pump/motor starts up when any button on the button pad is pressed, increasing the pressure up to the 0.8/0.9 MPa necessary to prepare the coff ee. The pump/motor are also controlled by the automatic level control device, which keeps the boiler fi lled with water.
In order to regulate the pump pressure, proceed in the following manner: loosen the lock nut, which holds the adjustment screw. Loosen the screw to reduce the pressure, or tighten it to increase it. When the operation is complete, make sure the lock nut is tightened once more.
INSTALLATION AND OPERATION MANUAL RESISTANCE 1800W 110-220V / 2400W 110V
3000-3500-3800-5000W 220-240V 2400W 110V
5000-6000W 220-240V 3000W + 1000W 220-240V 3000W + 1000W 220-240V
1800W 110V - 220-240V 1800W 110V
3000-3500W 220-240V 2400W - 110V
5000-6000W 220-240V
3000-3500-3800-5000W 220-240V 2400W 110V
5000-6000W 220-240V 3000W + 1000W 220-240V 3000W + 1000W 220-240V
ENGLISH
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62