IBERITAL 2.3.3. Alarm signals A. EXCESS BOILER WATER FILLING TIME The control unit has a waiting time for when the boiler is fi lling with water.
If the level sensor is not covered with water within one minute, the control unit safety control will stop the water fi lling process and the motor. The signal for the control unit alarm is the fi ve LEDs fl ashing simultaneously.
This alarm signal could be caused by a lack of mains water supply to the machine, an obstruction of the water inlet or a problem with the control unit that is preventing the signal for automatic water fi lling from being sent.
Warning: This alarm signal is always activated during the fi lling process when this immediately follows machine installation. This is due to the fact that it takes more than 1 minute to fi ll the boiler. When this happens, set the switch to zero and return it to the fi lling position in order to continue fi lling the boiler.
B. NO IMPULSES FROM THE FLOW METER (5 seconds)
If during feed there are no impulses from the fl ow meter, the control unit will detect it and the LED for the selection being dispensed at that moment will light up and fl ash, but dispensing will not stop.
This alarm signal is produced due to a bypass of the signal from the fl ow meter cover, or due to a poor connection, or lastly due to some internal problem in the control unit. If this occurs contact the after-sales service.
C. EXCESS FEED FROM THE FLOW METER
If the coff ee feed time is over 2 minutes, the control unit detects an excess in the normal coff ee feed time. Coff ee feed will be stopped automatically and the LED for the chosen selection will remain fl ashing.
This alarm signal is either due to an obstruction to the fl ow of water, and the control unit receives slower and more drawn out impulses than during the normal feed time, or because the coff ee is ground very fi nely or packed in the fi lter too tightly, causing excess weight, thus preventing the water from fl owing with suitable fl uidity.
D. DEPOSIT LEVEL INDICATORS (only portables machines) This machine has a system for indicating both minimum and maximum levels, which works as follows:
Minimum Level – When the water tank reaches its minimum level, the control unit cuts the current to the button pad and the heating element, in order to prevent damage to both the element and the pump due to a lack of water. At that moment the LEDs on the button pad will begin to fl ash, advising the user that the deposit must be fi lled.
When we begin to fi ll the deposit manually and the water covers the minimum level sensor, the LEDs will turn off and the control unit will once more allow the electrical current to reach the element and pump.
Maximum Level – When we are fi lling the tank manually with water and reach the maximum level, the LED on the non-stop button lights up, indicating that we must stop adding water to the deposit. This LED will remain lit until the water level is below the maximum level sensor.
GENERAL WARNING: If your machine has a visual display, the respective alarm will be shown on the screen based on the incident (see the section on visual display operation).
INSTALLATION AND OPERATION MANUAL
ENGLISH
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62