IBERITAL PreBrew. ON 1 espresso xxxx seg
The display will show the timer option for ‘PRE-BREW ON’ for each coff ee selection (1 espresso, 1 coff ee, etc.). Pressing the UP/DOWN buttons, the desired time in seconds (from 0.1 sec. to 5 sec. in jumps of 0.1 sec.) can be selected. Press the MENU button to select the ‘ON’ times for the rest of the selections.
Once this procedure is completed, press the MENU button to move on to the following option:
PreBrew. OFF 1 espresso xxxx seg
The display will show the ‘PRE-BREW’ timer ‘OFF’ option for each coff ee selection (1 espresso, 1 coff ee, etc.). Pressing the UP/DOWN buttons, the desired time in seconds (from 0.1 sec. to 5 sec. in jumps of 0.1 sec.) can be selected. Press the MENU button to select the ‘ON’ times for the rest of the selections.
Once this procedure is completed, press the MENU button to move on to the following option:
ProbeSensitivity LOW/MID/HIGH
The display will show the ‘PROBE SENSITIVITY’ option for the level of water in the boiler. Press the UP/DOWN buttons to select low (150KΩ), medium (400KΩ) or high (1 MΩ) sensitivity.
Once this procedure is completed, press the MENU button to move on to the following option:
Service Cycles xxxxxxx
The display will show the ‘SERVICE CYCLES’ option when the machine reaches the number of cycles selected. It will send a visual alarm on the display as notifi cation. Pressing the UP/DOWN keys selects the number of cycles.
Once this procedure is completed, press the MENU button to move on to the following option:
Heating Type xxxxxxx
The display will show the machine heating control system option.
Press the UP/DOWN buttons to select ‘Pressure Switch’, ‘On/Off ’ or ‘PID’ and confi rm by pressing OK. -Pressure Switch: boiler temperature controlled via pressure switch.
IMPORTANT: ANY MACHINE MODEL WITH TWO BOILERS MUST NEVER HAVE THE ‘Pressure Switch’ OPTION SELECTED, AS THE MACHINE WORKS WITH A TEMPERATURE SENSOR IN ORDER TO CONTROL THE COFFEE BOILER TEMPERATURE.
- On/Off : coff ee boiler temperature controlled via temperature sensor with hysteresis (the oscillation temperature interval for the boiler) of 0.5ºC, 1ºC or 2ºC.
- PID: coff ee boiler temperature controlled via temperature sensor, with variations in an algorithm of three constants Kp, Ki and Kd. (RECOMMENDED BY THE MANUFACTURER)
IMPORTANT: ANY MACHINE MODEL WITH A SINGLE BOILER MUST NEVER HAVE THE OPTIONS ‘On/Off ’ or ‘PID’ SELECTED.
In this position the machine will control the temperature according to its working conditions, adapting itself at all times to the internal and external contour conditions.
The values for these constants will depend on the power of the element, the size of the boiler and the degree of heat dispersion in the boiler.
INSTALLATION AND OPERATION MANUAL PRESSURE SWITCH
Xxxxxxx ON / OFF PID
ENGLISH
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62