IBERITAL 3.1.4. Iberital Expression Two
a) Pump + motor: feed the hydraulic system. b) Boiler:
• Double boiler: - 2 groups 3 litres (coff ee) / 7 litres (steam/hot water). - 3 groups 4 litres (coff ee) / 9 litres (steam/hot water).
c) Spring-loaded safety valve on the steam boiler. d) Pressure relief valve on the steam boiler. e) Boiler heating elements: heat the hot water in the boilers. f) Expansion/check valve: controls the pressure of the hydraulic system.
NOTE: On all machines there is a high-limit thermostat to control the temperature of the heating elements electrically: this thermostat limits the elements’ temperature. When the temperature is above the maximum level, the electrical power supply to the elements is cut. When this happens, the thermostat must be reset by pushing the button located on it, once the element is cold. (The thermostat can be accessed by removing the right panel on the machine.) In the case of machines with two boilers, there is one for each element.
NOTE: All machines have a boiler level sensor. For machines with two boilers, the sensor is in the steam/hot water boiler.
3.2.- WATER SUPPLY CONNECTION
IMPORTANT: This equipment must be installed in accordance with applicable federal, state or local regulations.
The machine has a 3/8” water inlet for the water supply. The said inlet incorporates a stop tap to open or close the fl ow of water (optional). Likewise, hoses are included. To be correctly installed, the mains water supply stop tap
will have to be connected to the previously mentioned inlet on the machine using one of these hoses, or similar. 3.3.- CONNECTION TO THE POWER SUPPLY
IMPORTANT: This equipment must be permanently connected to the power supply.
The machine is equipped with elements and other electrical parts at 110V, 220V-240V depending on the version. A switch must be installed, of a suitable calibre, between the permanent installation and the machine. The maximum electricity consumption is indicated on the rating plate.
The earth cable must be connected to an effi cient earth.
IMPORTANT: The machines can only be connected to 110V, 220V-240V depending on the version of the machine.
INSTALLATION AND OPERATION MANUAL
ENGLISH
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62