IBERITAL
2.6.2. Cleaning the groups - Machines without visual display
a) Substitute the normal fi lter (21c) or (21d) for the cleaning fi lter (blind) (21e). b) Add two spoonfuls of detergent (special for group cleaning) to the cleaning fi lter (21e). c) Insert the fi lter holder in the feed group. d) Press the non-stop feed button and let it run for 20 seconds.
e) Stop the feed by pressing the button again; during the decompression of the unit, the hot water and the detergent will clean the feed group interior.
f) Repeat this point (e) various times.
g) Rinse the unit and without the fi lter holders inserted press any feed button to eliminate any detergent residue.
- Machines with visual display (automatic washing):
When the coff ee machine is in working position (main switch in position 2 and hot), press (on any button pad of any group) the ‘non-stop’ button, and the ‘2 espressos’ button at the same time; the LEDs for ‘1 coff ee’ and ‘2 espressos’ will light up.
The visual display will show: Rinsing Then the machine will perform the following cycle 7 times:
- 15 seconds of feed - 2 seconds at rest
At the end of the cleaning cycle the machine will return to the start MENU. The cleaning cycle procedure can be carried out on all groups at the same time.
2.6.3. Cleaning the machine exterior
The machine’s exterior panels should be cleaned with hot, soapy water (not boiling) and completely rinsed using a soft cloth or sponge. Do not use abrasive products, as the panels could be scratched.
2.7.- CHANGING THE BOILER WATER • Disconnect the machine by setting the three-position switch (12) to the off position.
• Open the steam knobs (7) until no more steam comes out. (Use the steam dispensers (9) with care, as during normal operations they are extremely hot).
• Close the steam knobs (7). • Open the drain valve (26) until the boiler is completely empty. • Close the drain valve (26).
• Connect the machine, setting the switch (12) to position 1 (or switch (23) to ON) and wait until the automatic control system completes the fi lling of the boiler from the mains water supply.
INSTALLATION AND OPERATION MANUAL
ENGLISH
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62