This page contains a Flash digital edition of a book.
064 AUDITORIUM LIGHTING / BYU-IDAHO CENTER, IDAHO, USA


array provides a theatrical look and feel to the space. An all metal halide downlight system is provided for lectures, clean up and set up. These fixtures are switched and provide a high colour rendering, energy efficient and longer lamp life system for everyday use. When high light levels are required both systems may be used together to double the light level of either system used alone.


“The most important consideration was ease of operation and the ability to set up different light levels and looks depending upon the use of the auditorium, since the space will be used for performances and lectures. We wanted to design a system that would make the transition between the two different operating modes seamless and in- expensive by employing a dual system. For every day use such as lectures and gather- ings energy efficient long life lamps will be used. A warmer performance environment is required for special events and to that end fully dimmable incandescent lamps were selected to provide that soft glow so crucial to adding life to a performance space. Another important requirement was for the lighting of the auditorium to create a pleas- ant ambience during live broadcasts.” Decorative lighting elements assist in pro- viding a degree of visual relief in the large volume. At the leading edge of both balco- nies are glowing sconces that add rhythm


and sparkle to these long horizontal edges. At the rear of the main floor and at the back of each balcony level soft, glowing re- cessed ceiling fixtures were used in lieu of downlights. Surface mounted glowing wall sconces further enhance these locations. The combination of these lighting elements provides a softer glow to the lighting and contributes to the illumination of the ceil- ing and walls making these areas feel more spacious. The large side walls above the caliper side balconies feature three very tall vertical recessed sconces each. These glowing elements are backlit with dimmed LEDs in a very shallow enclosure. The decorative nature of this group of fixtures also adds lightness and sparkle into spaces. Caliper walls break down the massive main floor and help to create a more intimate feel in the huge volume. These walls were lit to accent and emphasize the rich wood finish. Low level steplights hidden in aisle side chairs and recessed into side walls complete the design and provide low level lighting during performances for all aisle ways and exit paths. According to French: “We met and ex- ceeded our design challenge, bringing a 15,000-seat auditorium and large lobby into a comfortable scale, while providing a light- ing system that is maintainable and energy efficient.” www.auerbachconsultants.com


The 76,000 square foot main lobby posed access challenges for maintenance of the lighting. To combat this, catwalks were built into the attic space above the ceilings to access downlights and accent lights. Where this was not possible, faceted mirror systems were fixed to the ceiling aiming at specific areas on the floor.


PROJECT DETAILS


BYU-Idaho Center Auditorium, Idaho, USA Client: Brigham Young University Architect: FFKR Architects


Lighting Design: Auerbach Glasow French Team: Larry French, MIES, LC, FIALD - Principal in Charge; Yukiko Yoshida, MIES, LC, IALD - Senior Associate and Project Manager; Marlene Lieu, LEED AP - Assistant Designer; Lily Tom - Technical Designer


LIGHTING SPECIFIED


Kurt Versen, Winona, Bega, Zumtobel, DAC, Focal Point, Selecon, GE Tetra, Lighting Services Inc., Deltalight, Insight, Columbia, Alera, ETC Paradigm Controls


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102  |  Page 103  |  Page 104  |  Page 105  |  Page 106  |  Page 107  |  Page 108  |  Page 109  |  Page 110  |  Page 111  |  Page 112  |  Page 113  |  Page 114  |  Page 115  |  Page 116  |  Page 117  |  Page 118  |  Page 119  |  Page 120  |  Page 121  |  Page 122  |  Page 123  |  Page 124  |  Page 125  |  Page 126  |  Page 127  |  Page 128  |  Page 129  |  Page 130  |  Page 131  |  Page 132  |  Page 133  |  Page 134  |  Page 135  |  Page 136  |  Page 137  |  Page 138  |  Page 139  |  Page 140  |  Page 141  |  Page 142  |  Page 143  |  Page 144  |  Page 145  |  Page 146  |  Page 147  |  Page 148