AN INTERVIEW WITH
Michael E. Dawson, Ph.D., RAC Director of Regulatory Affairs
Associates of Cape Cod, Inc. »
Walk us through recent developments in your LAL product offerings.
Associates of Cape Cod, Inc.’s (ACC) fourth generation tube reader, the Pyros® Kinetix Flex, offers the most sensitive bacterial endotoxin test (BET) available for both turbidimetric and chromogenic kinetic methods. In addition to flexibility of test method, ACC offers a choice of 32, 64 and 96 well readers. All of these readers provide the flexibility to add tubes at any time. Unlike a microplate reader, additional samples can be added after a test has been started. Also, we shall soon have an exciting new offering in the area of endotoxin testing.
Discuss techniques for overcoming inhibition and enhancement.
There are a range of strategies for overcoming interference. The most common technique is dilution. The test method is usually substantially more sensitive than is necessary to detect the endotoxin limit, which allows the sample to be diluted to overcome interference. For example, if the sensitivity is 100 times greater than the endotoxin limit (i.e. the maximum valid dilution is 100), the sample can be diluted by a factor of up to 100. In some cases, a particular test method may be less susceptible to interference by a particular product. ACC’s Contract Test Service can develop and validate a test method.
What are the core strengths of your Contract Test Services?
Our Contract Test Services group has more than 30 years of experience with products ranging from classic and novel drugs to biological products, medical devices of very different configurations as well as biologically-based medical devices.
In addition to routine testing, CTS has extensive expertise and the ability to:
• Develop methods for difficult samples such as liposomes, oligonucleotides and nanoparticles
• Work closely with clients to customize endotoxin testing to the individual clients’ needs
• •
Provide same day test for rapid turnaround Training and transfer of BET test methods developed
• Design and produce custom depyrogenation controls for oven validations.
20 American Pharmaceutical Review | Endotoxin Supplement 2013
CTS is GMP compliant, ISO 13485: 2003/2012 certified and licensed by the DEA as a laboratory capable of handling controlled drug substances other than those included in Schedule I. Endotoxin testing is performed in accordance with FDA guidance and USP, EP and JP requirements, as is appropriate for the customer’s needs.
What are the benefits of attending one of your BET workshops?
Our workshops are attended by people ranging from those who have never performed an endotoxin test to those with many years of experience. The workshops are educational, interactive and give hands-on experience conducting LAL tests and learning to read and interpret results.
The benefits of attending our BET workshops include: •
A better understanding of endotoxin and the BET through detailed demonstrations of the test methods including a discussion of laboratory set-up, materials, aseptic techniques, and sample handling/preparation, which can assist in developing a strategy to overcome interference.
•
A clear understanding of the regulations and standards applicable to endotoxin testing and the rationale behind them. This helps assure that the appropriate procedures and controls are in place for compliant testing.
ACC also offers a Bioburden, Endotoxin and Sterility Testing (BEST) training program in collaboration with EMD Millipore.
What does the future hold for LAL testing?
The future of endotoxin testing is bright, given the importance of QC testing of injectable products and non-pyrogenic medical devices. It is likely that new technology will become available and replace the current dominant technologies. However, the conservative nature of Pharma means that adoption of such new technologies will be slow. Any new technologies will need to be thoroughly validated and proven before they will be accepted by this highly regulated industry. LAL technology has protected and helped improve the quality of a wide range of critical healthcare products. The industry and the regulators will not want to leave behind this proven technology without the confidence of knowing the alternatives offer the highest levels of assurance of product integrity and patient safety. ACC is working towards this end.
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96 |
Page 97 |
Page 98 |
Page 99 |
Page 100 |
Page 101 |
Page 102 |
Page 103 |
Page 104 |
Page 105 |
Page 106 |
Page 107 |
Page 108 |
Page 109 |
Page 110 |
Page 111 |
Page 112 |
Page 113 |
Page 114 |
Page 115 |
Page 116 |
Page 117 |
Page 118 |
Page 119 |
Page 120 |
Page 121 |
Page 122 |
Page 123 |
Page 124 |
Page 125 |
Page 126 |
Page 127 |
Page 128 |
Page 129 |
Page 130 |
Page 131 |
Page 132 |
Page 133 |
Page 134 |
Page 135 |
Page 136 |
Page 137 |
Page 138 |
Page 139 |
Page 140 |
Page 141 |
Page 142 |
Page 143 |
Page 144 |
Page 145 |
Page 146 |
Page 147 |
Page 148 |
Page 149 |
Page 150 |
Page 151 |
Page 152 |
Page 153 |
Page 154 |
Page 155 |
Page 156