HVAC ELEVATING EFFICIENCY Helen McHugh of ebm-papst, explores the core benefits of
upgrading the fan component of a HVAC system to an Electronically Commutated (EC) motor.
HVAC systems are typically responsible for 60% of a building's energy consumption, so reducing the energy impact of these units can be very rewarding for building, energy and facility managers. One of the simplest ways to reduce energy consumption in a commercial building is to ensure all HVAC equipment is fitted with the highest efficiency ‘EC technology’ fans.
EC motors are brushless direct current (DC) motors powered by alternative current (AC) mains. They use permanent magnet motors, running on high voltage direct current (DC) electricity, with built in AC to DC conversion, allowing them to run direct from single phase or three phase mains supplies. The result is high performance, silent speed control and long-life expectancy in a product which is the same size as the old, power hungry AC products it replaces.
However, it’s not always financially viable to upgrade entire HVAC systems to reap the benefits of this improved technology. Here, we look at the five core benefits from only upgrading the ‘fan’ component of a HVAC system to EC technology. These systems include Air Handling Units (AHUs), Computer Room Air Conditioning Units (CRAC), chillers, condensers and fan coils units.
Energy savings equal financial savings In partnership with AB Group, we helped Marks and Spencer achieve energy savings of over £500,000 by upgrading to EC technology. Exactly 1,404 fans and 258 condensers were installed to 152 stores across the UK and Ireland. Following the upgrade, there is an estimated annual energy reduction of 3,265.3 kWh per fan, equalling a saving of £375.51 per fan, representing an annual saving of £527,223.
Reduce carbon emissions Since the Climate Change Act 2008, the UK Parliament aims to reduce the UK’s greenhouse gas emissions by at least 80% (from the 1990 baseline) by 2050.
As a result, when ebm-papst presented the Scottish Parliament with details of the energy savings achievable by upgrading their HVAC equipment to EC fans, a survey was requested. Working alongside equipment manufacturer Airedale; the project resulted in initial annual savings of 11.5 tonnes of carbon and an estimated total reduction of 20 tonnes.
Increased controllability In-keeping with our GreenTech philosophy, we made advancements to our variable speed EC fans, enabling them to be controlled and monitored remotely. These developments have enabled end users to quickly and
82 | TOMORROW’S FM
easily change the speed of the fans based on their needs, or the information from sensors and monitors.
In one case, we created a customised, stand-alone system that had fan alarm monitoring, as well as remote speed control for the fan coil units (FCUs) they were upgrading. This allowed the customer to set the speed of individual FCUs, and identify any failures or alarms from a single control box located in their facilities office. When they reduced the fan speed by 10%, we calculated an energy consumption saving of approximately 40%.
Longer service life EC fans have a longer life expectancy than AC fans. Due to the higher efficiency of the EC motors, they run much cooler which increases the bearing life. By replacing the fan component (which may be coming to the end of its life expectancy), the service life of the entire computer room air conditioning (CRAC) unit or air handling unit (AHU) is increased.
Reduce maintenance costs Most legacy CRAC and AHU units are fitted with belt driven centrifugal fans and external control electronics. These fans require a lot of space and have high maintenance costs related to wear-and-tear of parts. Often, large, inefficient belt-driven forward curved blowers are used. In comparison, EC centrifugal fans have impressive efficiency and compactness. Running costs and maintenance work are reduced by the simple ‘plug and play’ system which removes the requirement for transmission belts and commissioning. They can deliver overall efficiency of over 60%.
www.ebmpapst.co.uk/upgrade twitter.com/TomorrowsFM
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96 |
Page 97 |
Page 98 |
Page 99 |
Page 100