Laboratory Products 25 The Safest Filter for HPLC and Solvent Waste
Do you collect your solvents safely, and in line with the latest safety standards? The SCAT exhaust filter 3.0 blocks hazardous solvent vapours, and brings state-of-the-art safety to your lab. Thanks to 3 layers of different active carbons, it protects workers and environment from evaporating solvents, acids and alkalis.
SCAT exhaust filters block off harmful vapours and ensure for safe pressure equalisation in the waste containers of HPLC systems. The company’s core active carbon has been optimised for taking up organic solvent vapours and has been tested, using official ASTM/DIN/ISO test methods.
Especially in order to bind and remove alkaline and acidic gases, there are now two further layers of active carbon in the filters: the first contains a reactive impregnation which converts alkaline gases, by means of ‘chemisorption’, and then binds them as ‘fully reacted’ components. The second layer also consists of a highly active carbon, this one having been optimised for binding acidic gaseous components.
The active surface area has been increased by no less than 25%, i.e. from 1,200 m²/g to 1,500 m²/g. As per the ASTM D3467 Norm, the CTC adsorption value achieved by the new active carbon, Generation 3.0, is now 90% (hitherto 70%).
Traditionally-used active carbon (used for many years now), which however is not ideal for filtering out acids and alkalis, as it often only does so insufficiently. Its adsorption efficiency (‘CTC value’) is comparatively low, as is its active surface area (600 - 1,200 m²/g).
With their 3 layers, the Generation 3.0 exhaust filters are able to remove more gaseous components produced during HPLC work than any others available on the market. The main advantage for the user is that only a single filter type need be employed, for all applications - even when methods or solvent compositions used are altered.
The laboratory operator thereby achieves not only the highest possible standard of working safety and environmental protection, but also benefits from predictably high levels of efficiency, and by enjoying the associated cost savings involved - work in the laboratory is thus made ‘doubly’ safe.
More information online:
ilmt.co/PL/9Dae
56371pr@reply-direct.com
ADVERTORIAL
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56