39


MS compatible charge variant analysis of 28 commercial monoclonal antibodies by CEX


Cation exchange chromatography (CEX) is perceived to be the gold standard for the charge sensitive characterisation of monoclonal antibodies (MAbs). Acidic and basic variants caused by chemical or


Fig: Separation of 28 different commercial Mabs using YMC’s Bio Pro IEX SF column


enzymatic modifications can be separated from the main isoform of the MAb. These antibody variants have to be critically evaluated since differences in impurities and/or degradation products can lead to severe undesirable side effects.


Analysis of 28 MAbs with a broad range of pI


The application note described here is based on data produced by the University of Geneva, School of Pharmaceutical Sciences according to the method described by Yan et al. [1]. It shows the analysis of 28 commercial MAbs with different isoelectric points (pI 6.1–9.4) using YMC’s BioPro IEX SF column. Each MAb could be separated from acidic and basic variants which can be further characterised if coupled to a mass spectrometer (using a possible setup as described by Yan et al.). In contrast to the publication by Yan, fluorescence detection was used in this application note.


To achieve an acceptable elution window the initial and final ratio of mobile phase B was tuned for each MAb depending on its isoelectric point starting with an initial ratio of 20–30 % B (higher ratio for MAbs with higher pI).


Direct coupling of SCX to ultrasensitive MS


In a former application note based on a study by Yan et al., high resolution SCX (strong cation exchange chromatography) was coupled directly to an ultra sensitive online native MS [1]. A combined pH and salt gradient based on a MS compatible buffer system was utilised. YMC’s BioPro IEX SF, a non-porous strong cation exchange column, was used.


Reliable – Robust – Reproducible: BioPro IEX by YMC


One of the crucial requirements for any chromatographic QC method is a reliable lot-to-lot reproducibility for the column used. Unlike many other IEX columns on the market including widely used “standard” ones, YMC’s BioPro IEX columns provide excellent lot-to-lot reproducibility together with superior resolution. These features make them a first choice for Bio QC!


BioPro IEX columns are specifically designed for separation of antibodies, proteins, peptides, nucleic acids and oligonucleotides showing higher binding capacity and recovery of biomolecules compared to conventional IEX columns.


[1] Anal. Chem., 2018, 90, 13013-20.


MICROLUTETM The New Standard


CP for Solid Phase Extraction


Enhanced Reproducibility of Analyte Extraction & Recovery


Greater Performance, Cleanliness & Sensitivity


Reliable and Consistent Results


Take traditional solid phase extraction to a whole new level of perfomance with MicroluteTM


CP. Developed with the hybrid technololgy to enhance sample


preparation workflows where reproducibility and reliability matters.


www.microplates.com/microlute-cp


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56