38 February / March 2021
28. Broeckhoven, K., Vanderlinden, K., Guillarme, D., Desmet, G., On-tubing fluorescence measurements of the band broadening of contemporary injectors in ultra-high performance liquid chromatography. J. Chromatogr. A 2018, 1535, 44–54.
29. Deridder, S., Desmet, G., Broeckhoven, K., Numerical investigation of band spreading generated by flow-through needle and fixed loop sample injectors. J. Chromatogr. A 2018, 1552, 29–42.
30. Patel, D. C., Wahab, M. F., O’Haver, T. C., Armstrong, D. W., Separations at the Speed of Sensors. Anal. Chem. 2018, 90, 3349–3356.
31. Kempa, E. E., Smith, C. A., Li, X., Bellina, B., Richardson, K., Pringle, S., Galman, J. L., Turner, N. J., Barran, P. E., Coupling Droplet Microfluidics with Mass Spectrometry for Ultrahigh-Throughput Analysis of Complex Mixtures up to and above 30 Hz. Anal. Chem. 2020, 92, 12605–12612.
32. Welch, C. J., Are We Approaching a Speed Limit for the Chromatographic
Separation of Enantiomers? ACS Cent. Sci. 2017, 3, 823–829.
33. Grosse, S., De Pra, M., Steiner, F., Doubling the Throughput of Long Chromatographic Methods by Using a Novel Dual LC Workflow. Application Note 72601, 2018.
34. Schneider, S., Metzlaff, M., Ultrafast Analysis of Food Preservatives Using Automated Column Regeneration and Dual-Needle Injection. Application Note 5991-6150EN, 2015.
35. Welch, C. J., Ultrahigh Performance Liquid Chromatography: Key Enabling Technology for Pharmaceutical Discovery, Development, Manufacturing. Pittcon 2020. Chicago, IL 2020.
36. Guetschow, E. D., Steyer, D. J., Kennedy, R. T., Subsecond electrophoretic separations from droplet samples for screening of enzyme modulators. Anal. Chem. 2014, 86, 10373–10379.
37. Guetschow, E. D., Kumar, S., Lombard, D. B., Kennedy, R. T., Identification of sirtuin 5 inhibitors by ultrafast microchip electrophoresis using nanoliter volume
samples. Anal. Bioanal. Chem. 2016, 408, 721–731.
38. Ouimet, C. M., D’Amico, C. I., Kennedy, R. T., Droplet sample introduction to microchip gel and zone electrophoresis for rapid analysis of protein-protein complexes and enzymatic reactions. Anal. Bioanal. Chem. 2019, 411, 6155–6163.
39. Liénard–Mayor, T., Taverna, M., Descroix, S., Mai, T. D., Droplet-interfacing strategies in microscale electrophoresis for sample treatment, separation and quantification: A review. Anal. Chim. Acta. 2021, 1143, 281-297.
40. Jin, D. Q., Shi, S. W., Ma, Y., Fang, Q., LC-Swan Probe: An Integrated in Situ Sampling Interface for Liquid Chromatography Separation and Mass Spectrometry Analysis. Anal. Chem. 2020, 92, 9214–9222.
41. Reizman, B. J., Jensen, K. F., Simultaneous solvent screening and reaction optimization in microliter slugs. Chem. Commun. 2015, 51, 13290–13293.
New Liquid Chromatography Solution Redefines Laboratory Science
Waters Corporation has introduced the Waters™ ACQUITY™ PREMIER Solution, the next generation in liquid chromatographs featuring Waters’ breakthrough MaxPeak™ High Performance Surface (HPS) technology. The solution leverages HPS to vastly improve analytical data quality and eliminate the need for time-consuming and costly passivation.
The Waters ACQUITY PREMIER Solution combines the power of the ACQUITY PREMIER System with ACQUITY PREMIER Columns to improve detection sensitivity and assay-to-assay reproducibility for chromatographic separations of metal-sensitive analytes like organic acids, organophosphates, oligonucleotides, phosphopeptides, acidic glycans and phospholipids.
ACQUITY PREMIER is a universal liquid chromatograph (LC) solution that combines the ACQUITY PREMIER System with ACQUITY PREMIER Columns with MaxPeak HPS technology. It is designed to alleviate the problem of analyte/ metal surface interactions when analysing organic acids, organophosphates, oligonucleotides, phosphopeptides, acidic glycans and phospholipids by reversed phase and hydrophilic interaction chromatography. For these analyses, the new ACQUITY PREMIER solution cuts the time from sample to results, improves analyte recovery and assay- to-assay reproducibility, to give separation scientists greater assurance in the integrity of their qualitative and quantitative analytical results.
MaxPeak HPS technology is a hybrid organic/inorganic surface technology that forms a barrier between the sample and the metal surfaces of both the system and column. By mitigating, or eliminating altogether, non-specific adsorption, the ACQUITY PREMIER Solution offers many benefits, among them: increased analyte recovery with 10-100X improvement in detection sensitivity for low-level phosphorylated and carboxylated analytes reducing the risk of unseen analytes going undetected; sharper peak shapes and greater peak capacity for more accurate analyte identification and data interpretation; greater reproducibility for separations prone to adsorptive losses meaning less re-work or troubleshooting, and more confidence in results; no more system passivation to waste valuable sample material or tie up instrument cycles; eases the transfer of methods from site-to-site and from company-to-company; offers UPLC performance for the analysis of both metal- sensitive and non-metal-sensitive analytes making it a truly universal liquid chromatography solution.
The ACQUITY PREMIER System and ACQUITY PREMIER columns are now available worldwide from Waters. More information online:
ilmt.co/PL/Kg2G
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56