Gas Detection 39 Optical multi-analyte


meter with a sting in its tail The compact FireSting-PRO is a unique one-device solution for multiple analytes and sensor heads. It is a PC-controlled (USB) fi bre-optic multi-analyte meter, which can be combined with the complete sensor portfolio for optical O2


, pH, and temperature sensors from PyroScience.


Each of the 4 optical channels is freely confi gurable for several analytes and sensor types. These range from microsensors (50 µm tip) to robust probes (3 mm tip) and include diverse smart contactless sensor solutions (for measurements in closed systems / respirometry, microfl uidics and complex geometries), as well as sensors for different ranges (full and trace range O2


, pH ranges).


A precision Pt100 temperature sensor can be connected to the temperature port, enabling automatic zero noise and zero latency temperature compensation of the optical sensor measurements in samples with varying temperatures, even during high speed measurements.


The FireSting-PRO features improved ambient light suppression for applications at in situ light conditions, as well as smart measurement modes for a prolonged sensor lifetime. Several FireSting-PRO devices can be simply operated with a single PC in a single Pyro Workbench window, offering scalable fi bre-optic multi-parameter sensor systems with e.g. 8, 16, 32, or 64 channels. It has never been easier to measure important parameters in a single sample at high precision with maximum fl exibility concerning analyte, sensor format, measuring mode, and application range. These devices are also available as 1-channel and 2-channel version.


More Information online: ilmt.co/PL/XGzg For More Info, email:


email: 56131pr@reply-direct.com New two channel digital detector with digital interface –


for easy integration and precise measurements Analogue pyroelectric detectors from InfraTec have been used in a number of different customer applications for over 30 years. These have now been joined by a new range of digital pyroelectric detectors called PyrIQ. Alongside the 4-channel detector, InfraTec has also developed the LID-2322: a compensated 2-channel detector in the TO39 housing which is primarily intended for gas analysis devices.


The two-channel LID-2322 is ideal for mobile devices thanks to its small and compact housing and can also run on batteries. It is suitable for use in different applications, e.g. harsh environments, as the optional thermal compensation reduces the effect of external fl uctuations. The integrated I²C communication interface with up to 1 MHz enables the measured values to be read out immediately via a PC or microcontroller in a reliable, standardised manner. Apart from the power supply connections, only two additional connections are required for operation of the detector to allow it to be parameterised and read out. This keeps the external hardware requirements to a minimum and makes it much easier to integrate the detector into the application. Using the additional clock input makes it possible to synchronise the radiator and the detector clock, allowing highly precise signal evaluation with a stable frequency.


Like all detectors from InfraTec, the digital detector is based on lithium tantalate (LiTaO3) as sensor material. In contrast to other materials, LiTaO3 offers a good signal-to-noise ratio and high sensitivity without additional cooling or temperature stabilisation. All of the internal signal processing is carried out by an ASIC (application-specifi c integrated circuit). The signal generated by the pyroelectric elements is amplifi ed in this circuit and then digitised with a


16-bit A/D converter. In contrast to analogue detectors, this allows the detector parameters to be fl exibly confi gured in order to optimise the signal processing. The spatial concentration and shielding of the entire signal conversion of the detector offer improved electromagnetic compatibility (EMC). Another special feature is the “fast recovery after saturation” function. This function detects the override due to a defective operating status or external override and automatically resets the analogue input stage within a few milliseconds. This signifi cantly reduces the time it takes for a measuring system to be ready for use again after starting or after temperature changes.


All in all, the LID-2322 offers excellent fl exibility and functionality combined with easy system integration in the standard TO39 housing.


The most complete range of industrial gas sensing solutions


For More Info, email: email:


For More Info, email: email:


At NET you will fi nd: • NDIR SENSORS – no other manufacturer can offer a list of detected gases as comprehensive as NET when it comes to Non-Dispersive InfraRed technology: CO2 , Methane, hydrocarbons, SF6


and over 30 different refrigerant gases. Our Infrared sensors have reached a safety integrity level of SIL2. No other gas sensor on the market is provided with a higher, certifi ed SIL capability, making our IR series the ideal choice for whoever is designing gas detection systems and SIL-rated functions aiming at the highest levels of functional safety.


• ELECTROCHEMICAL CELLS - manufactured in Japan exclusively for N.E.T. and under our exact specifi cations to comply with performance requirements of EN 45544-2 – our line includes solutions for Carbon Monoxide (CO), Nitric oxide (NO), Nitrogen dioxide (NO2 dioxide (SO2 Ethylene (C2


), Hydrogen sulfi de (H2 ), Hydrogen Peroxide (H2 O2


), Hydrogen chloride (HCl), Chlorine (Cl2) H4


S), Sulfur ,


), Ammonia (NH3 ,


available in 4 different ranges) and the new H2S-HT cell for high temperatures.


• PELLISTORS – our catalytic bead sensor line is the ideal solution to monitor the presence of any combustible gas or vapor in air (or atmospheres containing oxygen) up to the Lower Explosive Limit (LEL).


• CYBER TRANSMITTER BOARDS - preconfi gured and pre- calibrated units that can fi t in any detector with a standard, high-level interface, sparing the user the need of calibrating the detector for the specifi c sensor employed and hiding the complexity of dealing with low level signal acquisition and processing.


• NET HEADS - A full range of ready–to–use detector heads or gas sensor housings, already certifi ed as a component or a complete device to be mounted on a gas detector in any environment – the ideal solution for gas detection system manufacturers who prefer not to invest in designing their own detection head and/or obtaining ATEX/IECEx certifi cation for it. N.E.T. heads can enclose NET full array of detection technologies along with CYBER transmitters.


More information online: ilmt.co/PL/lrmY 58210pr@replydirect.com


For More Info, email: email:


For More Info, email: email:


WWW.ENVIROTECH-ONLINE.COM


At NET we believe than an organization’s overall quality of work and processes is passed on to its products. This is why we maintain the industry’s highest standards of certifi cation, issued by the most renowned notifi ed bodies, including ATEX, IECEx, SIL and ISO9001.


For More Info, email: email:


Over 20+ years of existence NET has built the most complete range of solutions for the industrial gas detection market, making it the ideal one-stop shop for instrument OEMs worldwide. Our range of supply is not limited to top-quality sensing elements, but it extends to more integrated solutions which makes life easier for our users in terms of faster time-to-market when developing a product, simpler integration and great savings in their production processes.


57831pr@reply-direct.com


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96