Flow Level Pressure


Non-Invasive Optimisation – Overflash Mass Flow Measurement at 380°C using the Ultrasonic Clamp-On Technology


In petrochemical refineries, a multitude of measuring instruments monitor material transport and conversion. Flow measurement of the overflash volume, which is an important indicator for well-adjusted and efficient column operation, presents a special challenge. In the BP Oil Refinery Emsland in Lingen, a clamp-on ultrasonic measuring system measures non-invasively the heavy gasoil slowly flowing back during crude oil distillation.


The many processes running in a refinery form a highly complex system of material and energy flows, which can only be managed by means of a dense network of measuring points that continuously record all relevant parameters. In days of rising costs for energy and resources, measurement and control technology is more than simply ensuring that a plant fulfils its function; a constant optimisation of the plant's processes is required. Global competition makes it increasingly important to recognise and utilise all potential to minimise the required energy and maximise the yield. In the field of crude oil distillation, an important indicator for an efficient column operation is the overflash volume. The properties of the medium – a heavy and highly viscous gasoil – and the process conditions (low flow velocity and high temperatures around 380°C) make it very difficult to measure this quantity.


The BP Oil Refinery Emsland processes approx. 4.4 million tonnes of crude oil annually. Most of it is comes from the north-west oil pipeline, which also supplies refineries in the Ruhr and the Rhineland with imported oil unloaded from oil tanker ships at the harbour of Wilhelmshaven. But not all crude oil is equal. Its composition, and thus the percentages of light and heavy hydrocarbons it contains, varies depending on its origin. The process control has to respond flexibly to these differences in order to achieve the highest possible yield of desired products.


Difficult measurement


Usually, refinery plants almost exclusively use orifice flow meters because of the high temperatures. In Lingen, the overflash volume is conveyed in a 6" pipe located on the outside of the column. There, the overflash flows one column section downwards, driven only by gravity. Measurements using the differential pressure method are made particularly difficult by the low volume flow of 10 t/h at the most. In the small overflash return line, this means the flow velocity is never higher than 0.15 m/s. For orifice flowmeters, this means that an orifice plate with a very small diameter has to be used to obtain satisfactory precision. This results in a high pressure loss, which cannot be compensated with the available hydrostatic height. After a test measurement has demonstrated the suitability of non-invasive ultrasonic technology for this application, a system from Flexim (Germany) was installed at the measuring point: a FLUXUS®


meter with WaveInjector® . FLUXUS® uses the transit time difference principle to measure the


capacity. Their success is visible in the figures; in 2007, BP Oil Refinery Emsland achieved a plant availability of 98%, the capacity utilisation amounted to 90%. Especially as far as plant availability is concerned, the ideal solution would be using non-invasive measuring methods. The measuring unit for determining the overflash volume was installed without interrupting the production process. The measuring point is located in a potentially explosive atmosphere. Therefore the explosion-protected FLUXUS® is used as transmitter.


ADM 8027


volume flow. Since the physical conditions at the measuring point are virtually constant, it is easy to calculate the mass flow without recording the pressure and temperature. The recorded measuring values are fed into the process control system and are used for automatic control tasks.


Patented solution Flexim’s proven WaveInjector®


extends the possible


application range of non-invasive ultrasonic measurements to temperatures up to 400°C. The patented system consists of two coupling plates, each connecting a transducer with the pipe, yet keeping both of them a certain distance apart. The surface of these plates radiates enough heat to keep the temperature at the mounting point of the transducers within the permissible range. Simultaneously, the coupling plates ensure the acoustical contact between pipe and transducer. The mechanically robust mounting fixture maintains a high contact pressure. Specially designed metal foils replace the coupling gel and insure optimal contact and long-term stability.


The WaveInjector® is available in various sizes


is a purely mechanical arrangement, it can also be used in explosive atmospheres, together with transducers that have been tested and certified for explosion protection. It is not necessary to cut into any pipes to install the transducers. They can also be retrofitted - without downtimes or complicated approval procedures. The other advantages of clamp-on measurement – such as not being dependent on pressure or media, no wear caused by the medium, high measuring dynamics – of course still apply.


that each covers different diameter ranges. As the WaveInjector®


System and process optimisation


The oil refinery in Lingen, which started operation in 1953, was one of the industrial motors behind the economic development of the previously backward Emsland region. With around 600 employees and 75 apprentices, it is one of the most important employers in the region. However, compared to other national plants, and in particular to international ones, it is rather small. This makes it even more important for the people of the Emsland to optimally use the available


Author’s Details:


Catarina Kloss Flexim GmbH Wolfener Strasse 36, 12681 Berlin, Germany


Email: ckloss@flexim.de Web: www.flexim.de


Reader Reply Card No 177 New, Heavy Duty, Indicating Differential Pressure Switch


The new, Model 121 Indicating Differential Pressure Switch, by Mid-West Instrument (USA), is a heavy –duty version of the very successful Model 120 and features the rugged, field-proven piston/housing design of the 120. In addition, model 121 has a heavy-duty industrial type terminal strip for either one or two switches.


Wiring is easy with ½” NPT conduit interface and a removable


cover. A variety of switching configurations is available with one or two hermetically sealed switches in SPST, SPDT configuration with 240 volt, 3 Watt or 60 Watt ratings.


The model 121 is available in aluminum or 316 S.S. pressure housing with 316 S.S. and ceramic internal parts. Safe


Working Pressure is 6000 PSIG (0-400 bar). 121 Models are available in differential pressure ranges from 0-5 PSID (0-.3 bar) to 0-110 PSID (0-7 bar) with ± 2% accuracy. The weather resistant gauge front is of reinforced engineered plastic for corrosion resistance.


Reader Reply Card No 178


In addition to unlimited availability of the system components and full utilisation of their capacity, the optimisation of systems and processes is becoming increasingly important. In Lingen, a software for advanced control has been implemented for this purpose. It varies the process parameters based on mathematical models and the data from the process control system, and optimises the process using iterative learning control. An important measuring value for this purpose is provided by the high- temperature ultrasonic measurement at the overflash return line. As reliable data is now available on the quantities that return as a function of the various types of crude oil and of the way the column is being run, the process can be optimised to achieve more energy efficiency and yield.


For hot and cold


Ultrasonic flow measurement is a well proven alternative to conventional measuring methods. The WaveInjector®


opens up new areas of application


for non-invasive clamp-on technology; areas in which reliable and exact flow measurement with a high dynamic range was difficult, if not impossible, until now. Determining the overflash quantities in the distillation of crude oil is only one example. Petrochemical processes typically involve high temperatures and highly viscous media. In this area, non-invasive measurement with the WaveInjector® is very popular; e.g., for flow measurements on tar or bitumen.


The WaveInjector® principle of thermal decoupling is


equally effective on the other side of the temperature scale, i.e. for flow measurements at very low temperatures. The WaveInjector®


is for example used


to measure the flow of coolants in cooling systems, or cryogenic gases. The current boom of demand for liquefied natural gas – LNG – opens up further potential for this innovative measuring technology.


49


Flow Measurement up to 400 °C. Non-Intrusive.


No more process interruption during installation and maintenance.


refinery-solutions.com Reader Reply Card No 179 Annual Buyers’ Guide 2010


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102  |  Page 103  |  Page 104  |  Page 105  |  Page 106  |  Page 107  |  Page 108