Measurement and Testing


SIL-2 rated fl ow switch ensures eye wash station and shower fl ow assurance in hazardous areas


41


Lab-Accurate Water Quality Analysis


in a Pocket Pen Myron L®


offers pocket testers for produced and fl owback water testing that allow for


on-the-spot checks against automatic treatment systems in unit processes. Multiple models are available that include simultaneous measurement of Temperature along with another feature parameter: PT1 and PTBT1 measure Conductivity, TDS, and Salinity; PT2 and PTBT2 measure pH; and PT3 and PTBT3 measure ORP.


Plant operations and safety staff in the petrochemical, refi neries, chemical, and other industries required to comply with international legislation such as U.S. Occupational Health & Safety (OSHA) regulations for emergency eye wash stations and showers in hazardous areas will fi nd the SIL-2 rated FLT93 Flow Switch from Fluid Components International (FCI) helps them to ensure water fl ow and alert staff to station-in-use events.


Hazardous areas in the petrochemical and other process industry plants fall under OSHA 29 CFR 1910.151(c). This regulation requires emergency eye wash stations and showers be available that enable workers to fl ush themselves of corrosive materials. These emergency stations are to be located within the work area for immediate use. These OSHA requirements apply to many different hazardous industry processes, including chemical refi neries. They cover, for example, facilities with open tanks, which must have an emergency safety shower (or an alternative) within easy reach. Other process industries with dipping and coating applications must also comply. The pulp and paper industry, for example, must be concerned about worker lime or acid burns.


While the OSHA emergency eye wash station and shower regulations are defi nitive, there are equipment installation requirements also covered by the American National Standards Institute (ANSI) Z358:1 that must be met. Water temperature requirements are included in this checklist, amongst others. Eye wash stations and showers are to provide water over a temperature range of 60 to 100°F (16 to 38°C). Temperature control is important to prevent hypothermic shock (cold water) or scalding at higher temperatures.


FCI’s SIL-2 rated FLT93 Water Flow Switches feature global agency safety approvals for installation in hazardous areas. They are dual-function to alarm on both fl ow and temperature. When placed in an emergency eye wash station and shower water supply alarm system, they provide immediate detection of a station being used and are sensitive enough to signal operators of even a small leak. FCI fl ow switches are electronic fl ow switches. They apply thermal dispersion fl ow measurement technology to provide highly accurate and repeatable fl ow rate detection and provide equally reliable and repeatable relay trip points.


When the fl ow rate or temperature is above (high) or below (low) the setpoint, FCI’s electronic fl ow switches trigger a 6 amp relay to change state. The change in state can be applied to signal an alarm, to suspend, or shut-down the process, etc.


www.myronl.com 760-438-2021


Conductivity measurements test the effectiveness of reverse osmosis and resin ion exchange processes and are used to monitor for equipment failures and breakthroughs. PT1 and PTBT1 instruments are engineered with a proprietary conductivity cell that delivers accuracy of ±1% of reading and ±0.2% of reading at calibration point. Temperature compensation is automatic to 25°C but can be disabled by the user if required.


pH measurements provide a check against the automatic chemical feed that controls acidity or basicity of water in coagulation. pH directly affects coagulation because it affects the form and surface charge of both coagulants and impurities. It is also a fi nal quality control parameter that ensures water is ready for recycling in polymer gel applications. PT2 and PTBT2 instruments are accurate to ±.01 pH and employ a proprietary sensor with a large KCl reservoir for extended life. This sensor is also user replaceable.


ORP measurements ensure effective microbial control prior to recycling water in polymer gel applications. PT3 and PTBT3 instruments have been designed with user-replaceable proprietary sensors that are constructed of a 99.9% pure platinum electrode. Measurement accuracy is ±10mV.


ULTRAPENS are also easy to use. PT Series instruments feature one-button programmability, measurements, and calibration while the new PTBT Series pairs with most Android™ or iPhone® Bluetooth®-enabled devices allowing the user to control settings, measurements, calibrations, and data reporting tools from the PTBTX2™ mobile application. Later, the user can email data in .csv, .xls, .xlsx, or Myron L®


Company’s proprietary encrypted format, .mlcx, compatible with Guardian2 software.


All ULTRAPENS are compact, lightweight, dust-tight, and waterproof with fully encapsulated electronics and bodies of rugged aircraft aluminum.


More information online: ilmt.co/PL/PyQm For More Info, email:


email:


For More Info, email: email:


For More Info, email: email:


58070pr@reply-direct.com


Ultrameter ll™ A new level of outstanding performance...


E


Conductivity, Resistivity, TDS ORP/Free Chlorine Equivalent (FCE TM pH, Temperature


)


The unique sensor technology of the FLT93 Series Switches and superior temperature compensation circuitry introduce unparalleled repeatability and reliable trip point performance. Trip point accuracy on fl ow is as precise as ± 2% of the fl ow rate velocity over a ±50°F (±28°C) temperature range; repeatability is ±0.5% of reading. Temperature accuracy is ±2.0°F (±1°C), and trip point repeatability is ±1.0˚F (±0.6˚C). Dual 6A relay outputs are standard and are user-assignable to fl ow or temperature with the FLT93 Series Switches. A universal power supply supports powering by 115 Vac, 230 Vac, or 24 Vdc. The switch relay trip point/alarm is easily fi eld- confi gured or can be factory pre-set for ease of initial installation or changes later on. Featuring an all-welded, no-moving parts design, the FLT93 Switches require virtually no maintenance. There is nothing to break, clog, or foul requiring continuous maintenance. They are available in 316L stainless steel. In addition, these switches offer an exceptionally long life and a low lifecycle cost for superior value.


FCI’s FLT93 Series is the most popularly installed heavy-duty thermal dispersion fl ow switch in the world. The reasons are simple; FLT93’s were developed from decades of fl ow switch engineering and application installation experience to deliver the most reliable, repeatable, rugged and longest-life industrial-grade switch products found anywhere.


For More Info, email: email:


For More Info, email: 61607pr@reply-direct.com WWW.PETRO-ONLINE.COM


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88