search.noResults

search.searching

saml.title
dataCollection.invalidEmail
note.createNoteMessage

search.noResults

search.searching

orderForm.title

orderForm.productCode
orderForm.description
orderForm.quantity
orderForm.itemPrice
orderForm.price
orderForm.totalPrice
orderForm.deliveryDetails.billingAddress
orderForm.deliveryDetails.deliveryAddress
orderForm.noItems
12 Safety New and improved features for single-gas detector announced


Blackline Safety Corp. has announced a signifi cant upgrade to its G6 single-gas detector, adding new features and service plans to the life-saving wearable device.


G6 now features the same real-time connectivity as the company’s G7 product line. Additional new features include an emergency SOS that workers can trigger in critical situations to get help, and an expanded suite of data and reporting analytics. The device also supports indoor location technology. The company has introduced two new service plans—Protect and Protect Plus, starting at $10 per month— which bundle new features to fi t within any safety program.


G6 is a connected single-gas detector that uses instant cloud connectivity and location technology to help companies better protect their workers in industrial environments where exposure to toxic gases and hazards are common risks.


Supporting H2 S, CO, O2 or SO2 gas detection, G6 alerts the person when they have come into contact with gas—using attention-getting


lights, sounds and vibrations—and sends immediate notifi cations to emergency contacts. In a situation where gas has rendered a worker unconscious, these notifi cations coupled with the new SOS functionality can be life-saving both for the down worker and for others in the area.


G6 is powered by the company’s Blackline Live and Blackline Analytics platforms. Usage and compliance analytics enable companies to gain insights into when and where devices are being used and alerts occur, allowing them to address issues before they become dangerous and optimise their safety programs.


“We are further upping the standard for single-gas that we set last year. G6’s SOS feature makes sure workers can get help immediately when and where they need it, not just when they have been exposed to high gas. Added to that, real-time data around-the-clock, not just during an incident, allows companies to harness the information to improve worker safety and operational effi ciencies,” said Cody Slater, Blackline’s CEO and Chair.


A major energy company operating in the Permian Basin in Texas recently added G6 to its fl eet of connected safety devices from Blackline Safety.


“G6 fi lled a gap in our safety program, as we needed an easy-to-use and maintain device more suited to temporary or short-time visitors on site. This freed up our Blackline G7 lone worker and multi-gas detectors for personnel in more hazard-prone situations,” said a company representative. “With Blackline Safety, we get one partner and one platform to manage all our safety needs.”


G6 has a lifespan of four years and includes a rechargeable battery with up to one-year battery life from a single charge. Along with the new features, the company is introducing multi-unit charging stations—available in 5 or 25-unit confi gurations—which provide convenient charging options for customers’ G6 fl eets. Existing G6 units in the fi eld will be upgraded with new features through over-the-air fi rmware updates. More information online: ilmt.co/PL/beOY


New benzene-specifi c monitor for tighter international regulations


For More Info, email: email:


For More Info, email: email:


For More Info, email: email:


ION Science has launched a new, dramatically upgraded version of Titan, maintaining its position as the only fi xed benzene-specifi c monitor in the world; Titan 2. In accordance with recent legislation changes, Titan 2 offers enhanced stability and sensitivity, supporting ION’s continued mission of protecting lives and preserving the environment.


“Benzene is a toxic, carcinogenic gas representing a serious threat to many workers, as well as the environment,” explains ION Science Group Managing Director, Duncan Johns. “It is therefore vital that staff are protected by monitors that can continuously measure benzene at the low levels required by increasingly stringent international regulations. Titan 2 is the only commercially available, truly selective, fi xed continuous benzene monitor worldwide that can meet this requirement.”


Titan 2 delivers unrivalled accuracy and sensitivity in benzene detection and is ideal for use in a variety of sectors, such as oil & gas, bulk storage facilities, chemical manufacturing and processing, and asphalt production.


Users of the original Titan will be familiar with the instrument’s accuracy and performance, however,


within the new Titan 2 they will see core enhancements, such as a new rugged manifold, a piezoelectric micro pump for enhanced stability, a lower limit of detection, and updated PC software for easier management and control.


An occupational exposure limit (OEL) for benzene of 100 ppm was originally recommended in 1946. Following further associations with leukaemia, the OEL was reduced to 50 ppm and then to 1 ppm as the 8-hour time weighted average (TWA) exposure limit (U.S. OSHA, 1987). However, further health problems have been reported at levels below 1ppm so there is pressure in many countries to lower the limit further. For example, NIOSH recommended airborne exposure limit (REL) is 0.1 ppm (10-hr TWA) and 1 ppm during any 15-minute work period. Similarly, the current EU 8-hour TWA for benzene is 1 ppm (3.25 mg/m3). However, from 5th April 2024, the long-term exposure limit will be reduced to 0.5 ppm – and will be cut again from April 2026 to just 0.2 ppm. – Directive (EU) 2022/431 of the European parliament of the council, March 2022.


Regulatory requirements are therefore driving the need for greater sensitivity, and these needs are met by Titan 2. Thanks to innovative technology in conjunction with industry-leading PID sensor technology, the Titan 2 has a reduced likelihood of cross-sensitivity and can detect benzene rapidly at levels as low as 0.02 parts per million (20 parts per billion). At the other end of the scale, it can detect benzene at up to 20 ppm, delivering high speed and high sensitivity.


Titan 2 captures a gas sample once every 60 seconds. The sample is then conditioned within a further 60 seconds to allow precise benzene measurement, ensuring a consistent fl ow of real-time data. The piezoelectric micro pump in the latest version delivers enhanced pressure and fl ow accuracy to ensure a rapid response and unrivalled reliability.


Titan 2 also features visible alarm capability, triggering an alert when benzene concentrations reach either of two operator-confi gurable levels. Twin relay outputs enable the user to integrate the unit with existing site alarm systems, while easy-to-use fi rmware allows a simplifi ed calibration procedure. For analysis of readings captured by Titan 2, both 4-20mA and RS485 MODBUS communication protocols can be utilised.


A proven, robust separation method ensures specifi c readings for benzene, with an easy-to-read display. An internally regulated heating system ensures stable operation even at extremes of temperatures, and the new robust housing reduces contamination risk and allows for extended use in the harshest environments.


Titan 2 has been designed to comply with international safety standards, including ATEX and IECEx, making it safe for use in any environment, as well as featuring an IP65 Ingress Protection rating. ION Science’s photoionisation detection (PID) technology has been independently verifi ed as the best-performing on the market, providing reliable, accurate solutions backed by outstanding product support. Importantly, the new, unique to Titan 2, MiniPID T2 10.0 eV Sensor features a patented design to nullify potential humidity interference, whilst ensuring a fast response, the highest levels of sensitivity and market-leading reliability.


The Titan 2 service module is designed to be backwards compatible, so in conjunction with a simple fi rmware upgrade now provides existing Titan customers with a quick and convenient upgrade opportunity.


Summarising, Duncan Johns says: “Benzene is one of the more dangerous VOCs so the Titan 2’s ability to reliably speciate this gas is extremely important in the protection of lives, and with lowering regulatory limits, the instrument’s enhanced sensitivity is a major advantage.”


More information online: ilmt.co/PL/2XG6 For More Info, email:


PIN ANNUAL BUYERS’ GUIDE 2024 email: For More Info, email: 60714pr@reply-direct.com 61442pr@reply-direct.com


A novel methane optical gas imager for increased site safety and emission mitigation


CI Systems recently introduced MetCam, a state-of- the-art Continuous Emissions Monitoring System (CEMS) that utilises Quantifying Optical Gas Imaging (QOGI) technology. MetCam is a fully integrated autonomous system designed for detecting, monitoring, and quantifying natural gas leaks, and is available for installation in hazardous locations (Zone 1, Class I Div. 1).


MetCam’s innovative technology provides continuous monitoring of gas leaks and alerts users to the presence of hazardous clouds in real-time. With its ability to cover a large volume and detect even the smallest gas leaks, MetCam enables effective preventative maintenance operations to be conducted, minimising the risk of safety incidents and environmental impact. The system utilises advanced algorithms to minimise false alarms and operates reliably in demanding environments, ensuring accurate and reliable gas detection results.


MetCam is designed for installation in a wide range of natural gas facilities, including compression stations, natural gas skids, LNG gasifi cation/liquefaction facilities, fueling stations, and offshore applications. The system provides both visual and infrared video streams that can be displayed in the control room using the standard ONVIF interface, allowing for easy integration into existing monitoring systems. Additionally, MetCam offers industry-standard 4-20 mA output, enabling seamless integration into existing alarm systems for effi cient and effective gas leak detection.


One of the key advantages of MetCam is its reliability and maintenance-free operation. The system only requires periodic external cleaning to ensure peak performance, minimising downtime and maintenance costs for operators. With its advanced technology and innovative features, MetCam is set to become the go-to device for natural gas facilities looking to improve site safety, reduce fugitive emissions, and optimise their operations.


For More Info, email: email:


For More Info, email: email:


60177pr@reply-direct.com


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88