38


Analytical Instrumentation


Portable IR Analysers Provide Comparable ASTM/EN Data for Biodiesel Blend Measurements While Saving Time and Money


Both EN 14078 and ASTM D7371 methods for measuring the percent biodiesel in diesel fuel use infrared analysis as the analytical method and are based around using an FTIR spectrometer which has the capability to do a multitude of analyses besides the biodiesel in diesel measurement. This is great for a laboratory where various biofuels measurements are required. However, if the only measurement you need to make is biodiesel blend, simpler infrared (IR) analysers that only look at the frequency for biodiesel can be used. Reducing the complexity not only lowers the price but also makes it easier to use for non-technical personnel. Simplification also makes for a more rugged and portable system that can be operated right at a loading rack.


For the biodiesel measurement, IR light passes through the fluid and the amount of light absorbed by the biodiesel in the sample is measured. The absorbance increases and decreases with the biodiesel concentration so the IR absorbance can be correlated to a percent value. The simplified filter based infrared analysers use the same infrared measurement as FTIR spectrometers so results are comparable to both methods.


The most common concern is how filter-based infrared analysers compare to other reference methods. When single wavelength (InfraCal Biodiesel Blend Analyser) and spectral range (InfraSpec VFA-IR Spectrometer) filter-based analysers were compared to ASTM D7371 and EN 14078, they performed as well as the laboratory methods.


One disadvantage with the EN 14078 sampling method is that all samples require dilution with cyclohexane. This adds an awkward step to the analysis along with an added chance for operator error in the dilution process. The cell is also difficult to clean which adds the risk of leaving residual fuel in the cell that could lead to errors in subsequent samples. The calibration procedure for EN 14078 uses a linear regression calibration. One concern with this calibration method is some diesel fuels could potentially cause a reading offset.


ASTM D 7371 specifies an attenuated total reflection (ATR) sample system on an FTIR spectrometer to overcome the limited measurement range of a transmission sample system. The short effective pathlength of the ATR crystal allows measurement of samples having up to 100% biodiesel without dilution. The exposed ATR crystal is easy to clean reducing contamination issues.


The ASTM method utilises a chemometric calibration to try to account for the baseline offset that could come from different diesel fuels. It requires 70 calibration standards and uses three base diesel fuels. While a chemometric calibration will help with reducing the effect of different diesel fuels, there still could be some outlier diesel fuels that cause a reading offset.


The Wilks (USA) InfraCal Biodiesel Blend Analyser incorporates the most trouble-free portions of each method and is less expensive, easier to operate and more rugged than an FTIR spectrometer. A linear calibration similar to the EN 14078 method simplifies the calibration procedure. The exposed ATR crystal allows for easy introduction and cleaning of the sample as well as the extended measurement range from 0.2-100% without the need for sample dilution. The operator simply places a sample on the sample plate, selects the “run” button and a minute later the result is displayed. The plate is cleaned and the analyser is ready for the next sample.


While FTIR spectrometers have the capability to do much more than a simple biodiesel blend analysis, the InfraCal Biodiesel Blend Analyser is an ideal workhorse to provide on-site biodiesel measurements for those individuals who only need to do a routine blend check – easily, quickly and reliably.


For More Info, email: email: 281ad@reply-direct.com 26312pr@reply-direct.com


Total Acid Number on a Micro Scale


In a society where many industries are ‘tightening their belts’ and seeking ways to be greener there is an alternative to the typical Macro systems associated with TAN analysis. GR Scientific (UK) have developed the MicroTAN titrator dedicated to measuring Total Acid Number. The clue is in the name and no it’s not the smallest titrator in the world. In fact it is truly unique whereby only 25ml of organic solvent is used per sample compared to standard methods which can range from 60ml-120ml.


A reduction in solvent usage means less cost per sample and less solvent waste to dispose of.


High precision and dispensing accuracy is uncompromised due to the bespoke micro combination pH electrode and optimised titration vessel designed specifically for this system.


With many years of experience in the field of potentiometry, GR Scientific offer a full-support service and welcome the opportunity to discuss customer requirements.


For More Info, email: 26541pr@reply-direct.com


Aquamax KF Plus


Cont act us to find out more on +44 (0) 1525 404747 or visit www.grscientific.com


email: 116ad@reply-direct.com AUGUST / SEPTEMBER 2013 • WWW.PETRO-ONLINE.COM


A Truly V


ersat


Coulometric Karl Fischer Titr


ator


ile


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52