32 New Ball Mill for High Energy Milling Announced
With the new Emax Retsch has developed an entirely new type of ball mill for high energy milling. The unique combination of high friction and impact results in extremely fine particles within the shortest amount of time. The high energy input is a result of an unrivalled speed of 2000 min-1
and the innovative jar design.
Thanks to the revolutionary water cooling system, the high energy input is effectively used for the grinding process without overheating the sample. Due to the special grinding jar geometry, the sample is thoroughly mixed which results in a narrow particle size distribution.
Unlike other high energy ball mills, the Emax is capable of continuous grinding operation without interruptions for cooling down. This dramatically reduces the grinding time. The high energy input in combination with the unique cooling system provides perfect conditions for effective mechanical alloying or grinding down to the nanometer range.
A wealth of safety features such as the integrated safety closure of the grinding jar, temperature control with automatic start/stop system, and integrated imbalance controls make operation of the bench-top mill Emax very user-friendly.
More information can be found at
www.retsch.com/emax.
44033pr@reply-direct.com
Premium Pipette Tips Help to put the Focus on Canine Genetics
Mettler Toledo’s Rainin pipettes and TerraRack™ pipette tip racks are helping Paw Print Genetics in Spokane, USA, to offer a canine carrier screening service, enabling dog breeders to ensure the health of their animals. Kyle Sundin, Senior Manager, Development and Laboratory Operations, explained: “Paw Print Genetics is a molecular biology lab with a focus on canine genetic health. Testing for inherited conditions and traits – such as progressive retinal atrophy and hereditary cataracts – helps breeders to understand the genetics of these diseases and produce healthy animals, which is better for both the dog and its owner.”
“In our field of work, the potential for cross-contamination is a real issue; a sterile environment is essential. This begins with the pipette tip, and is one of the reasons we use TerraRacks with Rainin BioClean™ filtered tips. Previously, we used pre-racked tips for procedures performed prior to PCR, autoclaving empty boxes before refilling them to guarantee sterility. Boxes used for post-PCR procedures were simply discarded, generating large amounts of plastic waste. TerraRacks offer a high quality, premium pipette tip that ensures accurate dispensing, which is important for our work. Each box of tips is supplied presterilised, so we no longer have to spend time autoclaving them, and the impact of the waste on the environment is reduced as they use less plastic. We’ve fallen in love with them.”
44044pr@reply-direct.com ADVERTORIAL
Does Colour Measurement Make You See Red . . . or Yellow? Normally, when colleagues at the Tintometer®
Group initially explain what the company does, the typical response is a fairly blank look. This makes the standard ‘elevator
pitch’ somewhat challenging, unless you want to ride up and down a few times. Yet when you begin to explain the importance of colour measurement, the proverbial penny drops and the audience is captivated. Why, then, do we need to measure colour?
An end user may not consciously notice the colour of object or liquids unless the colour appears different than it usually does, and then suddenly the colour is all important. As soon as the colour difference is perceived, an unconscious signal is received implying that ‘different’ means ‘not as good’. Colour changes throughout the manufacturing process are to be avoided at all costs and normally are due to efforts of the Quality Control (QC) manager well before any product reaches the market.
In the edible oil and fats industry, however, colour measurement takes on a whole new role: the optimisation of bleaching, deodorizing, and other production processes. Most, if not all, refined oils are sold on the basis of their colour, and each type of oil will have its own ‘sell by colour’ instructions. So, it is necessary to monitor each stage of the refining process to establish whether the correct colour has been reached.
Some crude seed oils can have unexpectedly high pigmentation, often attributable to adverse growing conditions, such as too little or too much moisture or frost damage to the plant [1]. As a result, the colour tends to darken in storage. Early colour measurement can often alert the refiner to potential expensive bleaching and blending problems. Mixing problem oil with ‘in spec’ oils can compound the situation as the darkening effect is carried over [2]. Obtaining colour data regularly on oil suspected to be unstable would indicate its condition and help to avoid making incorrect decisions regarding blending.
Colour Measurement Methods and Colour Scales
Three things are necessary to perceive colour: (i) a light source, (ii) an object, and (iii) an observer/processor. However, colour is a perceptual property in human beings and is broadly described by descriptive words such as red, yellow, light, dull and the like. However, each person describes and therefore defines an object’s colour differently. To quote the 19th-century British Scholar Lord Kelvin: “When you can measure what you are speaking about and express it in numbers you know something about it; but when you cannot express it in numbers your knowledge is of a meagre and unsatisfactory kind.”
With this in mind, various methods have been developed to measure the colour of edible oils and fats. Colour can be measured visually by comparing glass colour standards in a colorimeter such as the Tintometer® communicative way.
Model F, using a series of gradient red-, yellow-, blue-, and neutral-coloured glasses. Any variation in colours can be measured and expressed in an easily understood and
The development of electronic instruments using multiple wavelengths and photodetectors made it possible to measure colour by using an optical system, such as a colorimeter or spectrophotometer. Today, Colorimeters, Spectrophotometers and Spectrometric Colorimeters are the most commonly used instruments. They measure the proportion of reflected or transmitted light at many points on the visual spectrum: plotting the points graphically to form a spectral curve.
Scales: Grading techniques are widely used to assess product colour by comparison with a representative series of fixed colour standards. For many product types, a characteristic set of standards was agreed and adopted to aid colour control and the communication of colour specifications; the result is a selection of traditional colour grading scales that have been adopted as industry standards and are still in common use today. For example, the Lovibond®
values locally and internationally. This is because the scale is simple to understand and communicate, and permits easy assessment by the plant operator. It is the only internationally accepted 3 dimensional colour scale that is offered in both a visual as well as an electronic instrument.
High quality processing in the edible oils and fats industry depends, therefore, on reliable testing. As a large proportion of the production is traded internationally, both suppliers and buyers need a common, easily understood language to determine product quality. Centralising on a mutually accepted colour scale ensures this essential communication. Reliable and repeatable test results are the key to ensuring final product quality and also to minimise production costs. Speed of analysis can also be vital for efficient process control and simplicity of operation helps to reduce error and increase productivity.
44607pr@reply-direct.com RYBN Colour is still the most popular scale in the Oils & Fats Industry, providing an easily understood method for communicating colour
LAB ASIA - JANUARY/FEBRUARY 2018
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52