Create a Secure Environment for Your Delicate
Cells with the Panasonic MCO-19 Incubator Series Incubators have long been classified as commodity equipment within a laboratory. By supporting both clinical and non-clinical applications from start to finish, they play a vital role throughout many testing processes.
The Panasonic MCO-19 incubator series offers researchers the most stable cell culture environment possible, with outstanding control of CO2 and O2 concentrations and continuous contamination control. This combination delivers significant advantages that assist laboratories in complying with today’s tightening regulations and standards.
CO2 and O2 control
The Panasonic MCO-19 incubator series’ infrared CO2 sensing system provides users with much needed accuracy through the use of a single beam, dual detector. CO2 levels are easily verified on the LCD display, and a CO2 sample port on the front of the incubator permits convenient confirmation of chamber CO2 density.
As well as precisely controlling CO2, the MCO-19M series delivers exceptional control of oxygen levels, essential for cell culture processes requiring very specific O2 concentrations. A zirconia oxygen sensor maintains sub-ambient O2 levels from 1% to 18%. Enriched O2 levels from 22% to 80% can be reached with proper safety precautions in place.
During use, sample and reference wavelengths are measured simultaneously for continuous auto-zero calibration. The electronic PID control ensures high accuracy by preserving temperature and gas set points over the entire system range.
Patented SafeCell UV® Panasonic’s SafeCell UV®
system system helps fight
contamination during use, minimalising interruptions, improving cell growth and reducing the risk of product loss.
The system includes a programmable UV lamp to decontaminate conditioned air and water in the humidifying pan. This thorough decontamination inhibits the growth of mycoplasma, bacteria, moulds, spores, yeasts and fungi without HEPA filters. An automatic UV cycle switches on automatically for a specified period after door opening to eliminate airborne contaminants.
Direct Heat
Panasonic MCO-19 incubator series instruments employ a direct heating system to guarantee highly reactive temperature control in response to door openings. This direct heating is provided by three independent heating sources surrounding the chamber. These are located in the top and rear wall, in the chamber base and outer door, and are controlled by the microprocessor PID control. The innovative outer door heater warms the inner glass door in relation to ambient conditions, preventing condensation and promoting temperature uniformity.
H2O2 decontamination option
The use of low temperature H2O2 decontamination is a popular, safe alternative to ethylene oxide decontamination methods.
The optional H2O2 decontamination process delivers a prompt instrument turnaround when a complete decontamination is required. The MCO-19 airflow system circulates air around the chamber throughout the cycle, ensuring all surfaces are reached before the UV lamp breaks down the H2O2 vapour.
The unique design of MCO-19 incubators
series permits the safe use of H2O2 decontamination with no impact on the surrounding environment. User safety is
assured by continuous monitoring, a H2O2 neutralisation cycle and physical door interlock.
These advanced technologies enable Panasonic incubators to provide the most stable cell culture environment possible, together with outstanding control over internal conditions. For more information, visit
www.panasonic.eu/biomedical
MORE INFO. 64
Exceptional CO2 & O2 recovery times Continuous auto-zero calibration
Direct heat & Air jacketed heating system Patented SafeCell UV destroys airborne and humidity pan contaminants
wwwpanasoniceubiomedical Fast & validatable decontamination option MORE INFO. 65
A secure environment for delicate cells with outstanding control and recovery performance
MCO-19 incubator series
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56