where drainage falls are insufficient. A tapered scheme is quick to install as the insulation upgrade and falls are applied in a single operation. Bauder has a patent-pending tapered insulation system, with innovative ridge and valley infill formations that enable both simplistic designs and the creation of complex fall configurations without the need to modify the building structure, creating cost savings for your client.


Create cost effective falls on a flat roof T


apered insulation can be retrofitted as part of the waterproofing system during the refurbishment of a flat roof


Key benefits • Incorporated within the warm roof construction of a refurbishment flat roof system


• Suitable for use with bituminous membrane, single ply or cold applied waterproofing systems to suit the project requirements.


• Flexibility to create complex configurations with multi-directional falls. • Creates 1:60 falls to comply with BS


6229:2018 Flat Roofs with Continuously Supported Flexible Roof Coverings.


• Granted BROOF (t4) to TS1187 and BS EN 13501-5 when used in a Bauder warm roof system.


• Good compressive strength to resist physical damage.


• Foil-faced for improved thermal efficiency


COMPLYING TO NEW BRITISH STANDARDS Falls


The BS 6229:2018 update, effective from November 2018, considers it good practice for flat roofs to be designed to clear surface water as quickly as possible. It is also required in Building Regulations Part H that ‘adequate provision is made for rainwater to be carried from the roof of the building’. According to BS 6229 & BS 8217, flat roofs should be designed with minimum falls of 1:40 to ensure a finished fall of 1:80 can be achieved. This applies to all roof areas including internal gutters and sumps.


Thermal performance


The minimum U-value levels permitted at any point of a heated building is 0.35W/m²K, including the thinnest areas of a tapered roof and gutters. Insulated outlets are required to maintain thermal continuity at drainage points. All Bauder designed schemes take these factors into account to adhere to the BS 6229:2018 update.


Bauder Tapered Insulation Design


Every roof will require a bespoke layout according to location of outlets or the drainage system which will dictate the direction of falls, maximum heights, acceptable weight loading, U-value to be achieved and budget costs. BauderPIR FA Tapered Insulation is faced


on both sides with black aluminium foil which increases thermal efficiency. The boards are available in a variety of thickness from a 1-board up to an 8-board to achieve the desired pitch and thermal requirements for each project. Using only one layer of tapered board atop 160mm FATE base layer of insulation makes for an easier, quicker and more cost-effective method of applying a tapered scheme.


How to specify a tapered scheme Bauder offers a tapered insulation design service with every scheme designed to match the needs of the project and meet building regulations - BS 6229:2018 for minimal thermal performance of the roof and thermal bridging resolution, BS 5250:2011+A1:2016 Code of Practice for Control of Condensation in Buildings and U-value calculations in accordance with BS 6946 Annex E (Calculation method) to confirm the thickness required and/or U value achieved.


0845 271 8800 www.bauder.co.uk


ADF OCTOBER 2019


WWW.ARCHITECTSDATAFILE.CO.UK


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100