CASE STUDIES
Underfloor a/c system brings increased design freedom
A
n underfloor air conditioning system from AET Flexible Space has allowed architects to highlight key architectural
features in a new high-concept refurbishment in the heart of central London. The 77 Coleman Street development, designed by Buckley Gray Yeoman architects on behalf of Kajima Properties, offers outstanding office space overlooking Coleman Street Gardens and less than a minute’s walk from the new Elizabeth Line station at Moorgate. AET’s underfloor air conditioning system makes use of the void within the building’s raised-access floor and so removes the need for traditional ceiling-based services and suspended ceilings. By using the existing 270mm floor void, the design team were able to preserve and highlight key architectural design features, including a unique terrazzo-
42 August 2020
patterned soffit. Moving away from conventional ceiling- based services has allowed 77 Coleman Street to boast unusually high floor to ceiling heights, creating a far brighter, more open, and inviting office environment. When used in refurbishments, underfloor air conditioning technology can typically offer increased headroom by 300mm or more.
AET Flexible Space worked closely with both the m&e consultant, The GDM Partnership, and award-winning architects, Buckley Gray Yeoman, for well over three years on the application and specification of their market- leading under floor air conditioning systems before receiving the official order from the appointed m&e contractor Designer Group. AET was also invited to present directly to the Kajima Properties development team and
Property Managers, to reaffirm that their UfAC systems would deliver to the high standards set out for Kajima’s first venture into the London property market. The Kajima team was incredibly impressed by the capabilities of the AET system, and endorsed its use over seven floors of 77 Coleman Street. The 77 Coleman Street development is now
in the final stages of completion. AET Flexible Space’s CAM-V underfloor air conditioning systems has now been installed across all seven floors of office space. Each floor is served by four CAM units, and the conditioned air is delivered into the space via 48 floor- recessed Fantile units. AET’s Fantile units induce conditioned air into the office space, eliminating cold draughts, while providing the end-user complete control over temperature and air flow.
www.acr-news.com
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68