FEATURE CABLE & CABLE MANAGEMENT GETTING SMART WITH CABLING
When people talk about ‘smart’ buildings they are usually referring to automation. However, there are also strong commercial reasons for getting smarter about the electrical fit-out, says Mark Redfern, managing director at Wieland Electric
T
here is no question that the design of buildings is becoming increasingly
‘intelligent’ – partly driven by technological advances and partly by improved project delivery through initiatives such as Building Information Modelling. In turn, these improvements in design can make it easier for building owners to operate and maintain their built assets through their life. There are many aspects of intelligent
design that contribute to this overall trend, but it is the most futuristic of these that tend to get the publicity and generate a level of excitement. However, it’s important not to lose sight of the more fundamental components that make up a building. A good example of this is the cabling,
without which such buildings would lack the connectivity required for smart performance. So it’s important to apply the principles of intelligent construction to the cabling methodology.
CUTTING COSTS One advantage of this is the ability to reduce the overall costs of construction for the end client, while maintaining profitability for the contractor. For example, the use of structured wiring with ‘plug and play’ connectivity has been shown to deliver significant savings in installation time. This was clearly illustrated in the
development of 5-7 St Helens Place in the City of London, where the Metalynx2 structured wiring system was used for connection of power and lighting. This allowed for recessed modular lighting and power to be fed via separate main distribution boards with home runs along the containment route out to open plan office areas. Wieland’s extenders, tees and fused spurs were also used to feed lighting control modules and coil fans on site. This use of a structured wiring system,
supplied complete to site for easy connection, allowed for a 70 per cent reduction in man-hours for installation. The system was specified and installed by The Designer Group and the company’s UK managing director, Nick Baish, observed: “The solution offered by Wieland has reduced our production time and offered a good quality installation with flexibility for future CAT ‘B’ fit out”.
26 APRIL 2016 | ELECTRICAL ENGINEERING
Similar benefits were experienced at 10 Hammersmith Grove, where the Metalynx2 system was used to distribute all the lighting and power throughout the building, which includes 8 floors of office space, a mezzanine area and the public ground floor section. Project manager Bobby Vance of contractors Imtech Engineering Services recalled: “We used the modular system for simple and quick installation. With a short installation time on-site the ability to provide a flexible solution during CAT A works meant Wieland’s modular product was ideal for the project”. Experience across many such projects has shown that savings of 70 per cent in installation time are typical when structured wiring systems are used. When this data is analysed intelligently, by taking into account the slightly higher capital costs of structured wiring compared to traditional wiring, there is still an average 30 per cent saving on final installed cost. Whilst this is an average saving across all project types, there are some projects where the benefits are even greater. Obvious examples include high bay lighting in ‘shed’ type buildings where any work on the lighting will require specialist access equipment. In such cases, as well as reducing installation time and working at height, additional savings are achieved by minimising disruption of the operations at ground level.
MAXIMISING EFFICIENCY There are also clear benefits to integrating different types of cabling when possible to maximise the efficiency benefits. At the Cannon Place commercial complex in the City of London, for example, Wieland’s Metalynx structured wiring system was not only used to connect the supply of light fittings, fan coil units, small power and cleaner sockets; it was also integrated with a DALI- based programmable control system. Structured wiring also makes it
easier to reconfigure systems in the future to accommodate changes in building usage or layout, thus supporting compliance with the government’s ‘Soft Landings’ concept.
Above: The Metalynx2 system has been used at 10 Hammersmith Grove to distribute all the lighting and power throughout the building
ADDED BENEFITS Another potential benefit for contractors is the ability to make better use of their multi-skilled operatives. For instance, the plugs on such systems are configured so they can only be plugged in one way – the correct way. This means that a qualified electrician isn’t required to make these connections. So, for example, mechanical operatives working at high level on pipework could also make the lighting connections. There are also opportunities to make the cabling more discreet when combined with newer technologies such as LED lighting. As LED lighting itself tends to be more compact than traditional luminaires it makes sense to use ‘micro-connectors’ that are easier to hide. Intelligent buildings are already a
reality and smart construction processes will very quickly become the norm as BIM becomes the project delivery model of choice. It seems clear that structured cabling has an important role to play in both the construction and the ongoing management of these smarter buildings.
Wieland Electric
www.wieland-electric.com T: 01483 531213
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64