DATA CENTRE MANAGEMENT FEATURE


Working with data inputs from the extensive instrumentation that Comtec had previously installed, the new software module provided a much more comprehensive picture of power and cooling consumption throughout the data centre infrastructure and presented it on a centralised console, where it could be easily viewed and analysed by Beedie and his team. It allowed them to get a much deeper,


Continued from Page 10... Calculating PUE accurately for a data


centre with such mixed functions presents its own challenges. Cooling provision for the systems that support the general IT needs remain reasonably consistent, whereas, for the high- performance work that ARCCA performs, the systems tend to be operated at peak.


ENERGY EFFICIENCY UPGRADE As part of the power and cooling upgrade managed by the University’s Estates division, Comtec deployed Schneider Electric’s Data Center Operation: Energy Efficiency module as an additional component to the previously installed StruxureWare for data centres.


Hugh Beedie, chief technology officer, worked closely with the ARCCA team to ensure the HPC Datacentre infrastructure is truly fit for purpose


more granular insight into energy usage, not just at an overall site level but also at subsystem level. Critically, it did so in real time. This enabled Cardiff to monitor the effects on energy consumption of changing fan speeds, of CPU utilisation on a server rack, or of raising the temperature of the chilled water supply. The new cooling services design had


some specific elements aimed at improving energy efficiency. For example, the replacement of all three existing chillers with new high efficiency 300kW models, to provide a symmetrical system, and the introduction of a secondary cooling circuit. Individual high efficiency Variable Speed Drive (VSD) pumps were also fitted individually to each chiller to give better ‘turn-down’ ratios.


IMPROVED EFFICIENCY The new cooling equipment upgrade, together with the new monitoring software, has seen major improvements in the energy efficiency of the data


centre, despite the additional HPC servers. Depending on ambient heating conditions, the real time PUE rating has been as low as 1.2, according to Beedie. “The additional information about


energy consumption has enabled me to see the real-time effect of warm weather as the day heats up. As the day starts, our PUE figure is running at about 1.20 but by the end of a hot afternoon it’s up to about 1.25, 1.27 and then drops down again as the evening cools. This degree of detail enables me to be confident that we are adopting an appropriate operating regime for the cooling system.” Monitoring the effects of small changes to operations in real time, enables clarity about the interaction of the control of the chillers. It also gives an insight into the operation of the HPC servers. For example, if the chillers are running below maximum power, it can be immediately seen whether it is more efficient to run all three at reduced load, or turn one off and run the remaining two at part load. “The only way you can clarify this is by having this instrumentation and trying it under varying operational conditions,” he says.


CP Electronics www.cpelectronics.uk.com T: 0333 900 0671


Advanced G59-3/G83-2 decoupling protection for micro generators Choose Linetraxx VMD460


• Easy installation and commissioning with pre-configured settings and test simulation.


• Competitively priced protection you can trust - manufactured in Germany.


• Tested and certified to G59-3, G83-2 by independent test labs. ANSI Protection Function


27 Under Voltage – 2 stages 59 Over Voltage – 2 stages


81U Under Frequency – 2 stage 81O Over Frequency – 2 stage 81R ROCOF – Rate of change of Frequency 78 Vector Shift Phase Sequence Voltage Asymmetry/Phase failure


86 Lockout 47


 LINETRAXX® VMD460 G59-3/G83-2 decoupling protection relay Choose Bender for cost effective safety and quality - www.bender-uk.comELECTRICAL ENGINEERING | APRIL 2016 13 • Vector shift and ROCOF in a single unit


• Password and padlock security with history of up to 300 events.


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64