40 chromatography • spectroscopy


preparation supplies, enables sensitive, selective and robust techniques for measuring trace components in complex matrices. In addition, our extensive MRM database of pesticides and environmental pollutants provides all the information needed for quick and easy method development.”


A new standard in LC columns Just released onto the market from Waters are CORTECS Columns, a new family of 1.6 micron solid-core UltraPerformance LC columns which the company says set a new standard in LC column performance. Te higher efficiency brought to chromatography with CORTECS Columns allows laboratories to produce greater amounts of information faster with every chromatographic separation.


Available in C18, C18+ or HILIC chemistries, Waters offers the columns in 30 novel column configurations and is making them available for shipping worldwide (Fig. 1). Te company says that when used together with the low-dispersion ACQUITY UPLC, ACQUITY UPLC I-Class and ACQUITY UPLC H-Class Systems, CORTECS Columns offer previously unattainable levels of performance.


CORTECS Column particles feature a solid, impermeable silica core encased in a porous silica outer layer where the interactions between the stationary phase and the analytes occur. Te three CORTECS chemistries and their intended uses are: CORTECS C18 Column - a general-purpose, high-efficiency, reversed-phase column offering balanced retention of acids, bases, and neutrals at low and mid-range pH; CORTECS C18+ Column - a general- purpose reversed-phase column with a positively charged surface that delivers excellent peak shape for basic compounds at low pH; and CORTECS HILIC Column - designed for the retention of extremely polar analytes while offering orthogonal selectivity versus C18 columns.


Modular ion chromatography Cecil Instruments describes its new IonQuest as a top performance, modular ion chromatography system. Te conductivity cell of the conductivity detector is enclosed with a heat exchanger in a precisely thermostatted enclosure. Te temperature of the enclosure is controlled to better than ±0.01°C. Te working temperature may be set by the analyst to be between 25°C and 50°C and set with a default value of 35°C during production testing.


Te system is easy to use by control panel operation, or by using the sophisticated Cecil PowerStream software for data acquisition, processing and reporting.


Te modularity of the system enables its configuration to be changed with ease, for instance for use with a UV/visible detector. Modules may readily be replaced, to reduce down-time, should the need arise.


Te very precisely temperature controlled oven accommodates anion and cation columns and pre-columns, as well as a background suppressor cartridge with its over-pressure protection valve. Close coupling to the detector provides high stability, low noise and low dispersion.


Te CE 4710 conductivity detector used here is an entirely new design from Cecil Instruments, providing performance of the very highest order due to its exceptionally low noise and unrivalled baseline stability. To achieve this standard of performance a very low volume, 0.5µl conductivity cell has been designed and is operated in a precisely thermostatted aluminium oven enclosure. Te specially designed, low dispersion heat exchanger is also mounted in the cell enclosure preceding the detector cell. Te exchanger stabilises the temperature of the


mobile phase entering the cell.


Sensitivity for the measurement of anions is greatly improved by reducing the conductivity of the eluent post column. An optional anion membrane suppressor - SAMS - is available which is mounted in the column oven, in series with and after the analytical column.


Finally, designed for both preparative and analytical purposes, GE Healthcare has launched Superdex 200 Increase SEC columns. Tey enable higher purity and improved protein analysis for a broad range of biomolecules.


Te new columns are capable of delivering up to double the resolution in the same time or the same resolution in a half the time compared to Superdex 200. In addition, they are optimised for MAb separations.


Superdex 200 Increase pre-packed columns can be used for small-scale (µg-mg) high-resolution size exclusion chromatography (gel filtration) and for characterising a variety of different proteins with molecular weights between 10,000 and 600,000. Tey are available in three sizes - 10/300 GL, 5/150 GL, and 3.2/300 GL - and can be used with ÄKTA chromatography systems as well as with different HPLC systems.


T


New columns offer enhanced retention of polar compounds It will be available in 2µm, 3µm, 5µm and 10 µm


he first of two new releases from Advanced Chromatrography Technologies (ACT) is the ACE C18-Amide is a new, specially designed


stationary phase offering enhanced retention of polar compounds with alternative selectivity to C18 based products. The ACE C18-Amide provides retention for polar to


non-polar analytes with multiple modes of interaction. It therefore perfectly complements the existing unique ACE portfolio products such as ACE C18-AR and ACE C18-PFP which provide alternative selectivity and ideal retention for moderately polar to non-polar analytes.


www.scientistlive.com


particle sizes offering excellent peak shape, stability and robustness and still based on the same ultra-pure ACE silica. The new C18-Amide comes with all of the ACE portfolio characteristics such as reproducibility, high quality and performance, notes the company. Second up are the ACE SuperC18 Ultra-Inert


UHPLC and HPLC columns that exploit selectivity at low, intermediate and high pH and are ultra-inert for maximum performance and reproducibility. According to the company, ACE SuperC18 UHPLC and HPLC columns are an idea column choice for


method development: exploiting selectivity changes at low, intermediate and high pH and have an excellent column lifetime for reduced analysis costs. ACE SuperC18 columns are recommended for high


and low pH mobile phases from pH 1.5 to pH 11.5 and are specially designed for use with LC/MS compatible buffers. With ultra-low bleed and rapid column


equilibration without memory effects, while also being compatible with MeOH AND MeCN, the ACE SuperC18 UHPLC and HPLC columns also have improved LC/MS compatibility.


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68