Non-Hardening Mountant Solutions Glycerol-Based
n Citifluor AF1 Mountant Solution Usage
Mounted in Citifluor AF1. GFAP (glial fibrillary acidic protein) labeled with Alexa 568. Vimentin GFAP complex. Hoechst 33342 nuclear stain. Vimentin Alexa 488.
Courtesy of Kin Pong U and Dr. Patrizia Ferreti of the Institute for Child Health UCL UK.
AF1 is a mountant solution composed of glycerol, phosphate buffered saline and an antifadent. It was specifically designed to stop the photobleaching of the fluorescein moiety of FITC labeled biological specimens. AF1 is useful for many other fluorochromes such as DAPI, rhodamines, Hoechst, Alexa and cyanine (Cy-3 and Cy-5) dyes, Texas Red, phycoerythrins and Green Fluorescent Protein (GFP). It is ideal for examining tissue sections and dead cells. In addition, it has been found useful for stabilizing the AUTOFLUORESCENCE of species such as cyanobacteria. AF1 solutions have been employed with the following techniques; fluorescence in situ hybridization FISH (including CARD-FISH) and confocal laser scanning microscopy (CLSM) are being used.
The solution has a pH of ~10. The solution should be pipetted onto the specimen and then a cover slip applied. If the slides are stored in a refrigerator, the viscosity of the mountant solution increases thereby helping to keep the cover slip in place. There is no need to seal the cover slip with nail varnish. Specimens mounted in AF1 solutions have been kept in this way for many months without suffering damage.
Mounted in Citifluor AF1. GFAP (glial fibrillary acidic protein) labeled with Alexa 568. Vimentin GFAP complex. Hoechst 33342 nuclear stain. Vimentin Alexa 488.
Courtesy of Kin Pong U and Dr. Patrizia Ferreti of the Institute for Child Health UCL UK.
Properties and Storage
The solution is of medium viscosity and has a water- white in appearance. It may be stored at room temperature and ideally between 5° and 15° and out of strong sunlight. The cap of the bottle or if using the pipette supplied with the material, the cap which covers the pipette delivery point, should always be replaced after use since the solution is hygroscopic. Samples stored under these conditions for 6 months have shown no apparent deterioration. If the AF1 solution is being used in an assay, a control experiment should always be carried out.
Obtaining the Correct Viscosity for your Application
Mounted in Citifluor AF1. GFAP (glial fibrillary acidic protein) labeled with Alexa 568. Vimentin GFAP complex. Hoechst 33342 nuclear stain. Vimentin Alexa 488.
Courtesy of Kin Pong U and Dr. Patrizia Ferreti of the Institute for Child Health UCL UK.
6
If the viscosity of the AF1 solution is too high for your purposes, it may be admixed with AF3 mountant solution. As the amount of AF3 solution is increased so the viscosity decreases. Conversely, if you wish to have a higher viscosity add AF2 mountant solution to the AF1 solution. Increasing the amount of AF2 solution increases the viscosity.
www.emsdiasum.com
www.citifluor.com