UV-Vis: 5 steps to Pharmacopoeia compliance Nathan Hulme, Starna Scientifi c Ltd
‘UV-Vis’, UV-Visible spectro(photo)metry, is one of the most widely used instrumental techniques in pharmaceutical analysis; the Unites States Pharmacopeia contains no less than 155 monographs describing UV-vis methods. Instrument qualifi cation, the process of demonstrating that an instrument can perform the required analysis, is now an integral part of any laboratory quality regime. Recent changes in the pharmacopoeias have made compliance more complicated, but still achievable by following a few simple steps.
Analytical Instrument Qualifi cation (AIQ)
USP guidance document <1058> describes the four stages of AIQ: design qualifi cation (DQ), installation qualifi cation (IQ), operational qualifi cation (OQ), and performance qualifi cation (PQ). Good quality control also requires that documented Standard Operating Procedures (SOPs) are used and that instruments are regularly calibrated.
DQ: DESIGN QULIFICATION IQ: INSTALLATION QUALIFICATION OQ: OPERATIONAL QUALIFICATION PQ: PERFORMANCE QUALIFICATION
SOPs DQ IQ OQ PQ Calibration The four stages of Analytical Instrument Qualifi cation (AIQ)
DQ - Design Qualifi cation defi nes the operational specifi cations of the instrument. Many users would see this as the responsibility of the instrument manufacturer, but as it is the application that determines the performance required, onus is on the user to select an instrument capable of performing to the necessary standard and consequently ‘fi t-for- purpose’. The recent revision of USP <857> includes metrics to assist this selection process. Careful selection can also avoid the purchase of over-specifi ed and hence expensive instrumentation!
IQ - Installation Qualifi cation establishes that an instrument is properly installed and works to the manufacturer’s specifi cation.
OQ –Operational Qualifi cation demonstrates that the instrument is suitable for the intended use and analytical procedures for which it is to be used. It is not just that it performs to specifi cation! This is usually accomplished by the measurement of recognised calibration standards with accurately known properties. It is the choice of these standards that the recent pharmacopoeia changes have made more complicated.
PQ – Performance Qualification demonstrates on an ongoing basis that the instrument continues to perform and that it can produce test results of the required accuracy and precision. While the former can be tested using the same calibration standards used for OQ, the latter could involve the analysis of standard samples of the actual analyte.
The fi ve steps to compliance
1. Identify the standards that you need to comply with (e.g. European Pharmacopoeia, US Pharmacopeia)
2. Select the monographs describing the analyses you wish to perform.
3. Confi rm that the specifi cations of the available instruments meet the requirements of the monograph(s) or, if the monographs do not state specifi c instrument performance limits, the generic criteria given in the pharmacopoeias. If selecting a new instrument, this is the user’s DQ process.
4. Identify the appropriate wavelength and photometric (absorbance) ranges over which you will be working.
5. Select appropriate reference materials from a properly accredited supplier Qualifi cation – parameter ranges
Earlier versions of the pharmacopoeias described a limited set of generic tests to qualify an instrument for wavelength, absorbance, stray light and resolution (spectral bandwidth) – in some cases one test per parameter. If the instrument passed these tests, in could be described as ‘pharmacopoeia compliant’. The same parameters must still be qualifi ed, but now users must demonstrate ‘fi tness for purpose’, i.e. that the instrument has the performance to perform the analysis to the required accuracy and precision. The qualifi cation measurements must therefore be made at parameter values that match, as closely as possible, those used in the analysis. It is also recommended that the values of the references used for qualifi cation should ‘bracket’ the values expected in the analysis. Two references at the extreme ends of the parameter ranges could not be said to bracket the analytical values, so if a wide variety of analyses is to be carried out, several references will be needed to cover the range of parameter values involved. To facilitate this, several new reference materials are cited in both standards, all of which are commercially available as Certifi ed Reference Materials (CRMs). Both EP and USP allow the use of CRMs, indeed the USP strongly advocates their use in preference to laboratory-prepared references.
Reference material selection
The next step, then, is to identify the analytical wavelengths to be used and the absorbance values to be expected. The chart below gives an indication of the wavelength ranges of various commercially available CRMs for the four usually qualifi ed parameters.
UV Nicotinic acid solution Absorbance
Potassium dichromate solution Starna Green
Neutral density filters Metal- on- quartz filters
Starna Deep UV Cerium solution Holmium solution Didymium solution
Wavelength
Holmium/Didymium solution Holmium filter Didymium filter
Resolution Stray light
Cut- off filters Toluene in Hexane UV 200 265 270 VISIBLE Wavelength ranges of various commercially available CRMs
Choosing wavelength CRMs is relatively straightforward as most of them have several certified peak values over their working ranges. Absorbance CRMs require a little more thought. In the far UV, between 210 and 250 nm, nicotinic acid is the usual recommendation, but Starna Scientific’s ‘Deep UV’ reference allows qualification down to 190 nm. At higher UV wavelengths there is more choice: the very well established potassium dichromate, the proprietary Starna Green CRM and metal-on-quartz filters. Potassium dichromate needs no introduction, but Starna Green has peaks over a wider wavelength range so may prove more generally applicable. See spectra on next page.
Metal-on-quartz filters look attractive, as they cover wavelengths from 250 nm to the near infrared, but they work partly by reflection, so stray reflections within the sample compartment could affect the measurement accuracy. Potential users should contact the manufacturer of their instrument to check its compatibility with these filters.
For stray light qualification, the EP formerly named just one stray light reference, potassium chloride solution, but both standards now list several references covering wavelengths from 190 nm to 400 nm and again a choice should be made to bracket the analytical wavelength(s).
NIR 190 200 240 290 240 270 430
Wide Range reference (NIST SRM-2065) NIR reference
335 930 440 640 890
1945 2550
795 210 235 250 440 250 230 300 650 870 260 430
650 635
2850 VISIBLE NIR
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84