38 AIRMONITORING


New emission monitoring solution helps the maritime industry achieve decarbonisation targets The launch of ABB’s CEMcaptain will help shipping comply with the sulphur emission regulations that were enforced in 2020, and keep in check their CO2


footprint.


In January 2020, the low sulphur and nitrous oxide emission limits in the International Maritime Organization regulations became effective worldwide. CEMcaptain is a powerful emissions monitoring system from ABB designed to help the maritime industry meet these new regulations and become more sustainable. Its measurement and digital capabilities increase on-board safety, provide process optimisation and substantially reduce ownership costs. By consistently achieving 98 percent and more uptime, the new system not only requires less maintenance effort but also saves time otherwise spent on handling non-compliance issues.


Designed with busy mariners and a regularly changing crew in mind, CEMcaptain is a multi-component analyser system that continuously provides real-time data offering reliable measurement of emissions with the highest stability. Operating in even the harshest of conditions it integrates analyzer modules and sample handling components in a standalone cabinet, making installation easy.


Equipped with ABB’s renowned Uras26 non-dispersive IR gas analyser, CEMcaptain simultaneously and continuously measures sulphur dioxide (SO2


continuous CO2


) and carbon dioxide (CO2 /SO2


) in line with regulation requirements. Each analyser has two separate gas paths to allow for measurement of separate streams, with up to four different components per analyser module.


“Our solutions are driving the evolution of sustainable shipping, paving the way to a zero-emission marine industry. ABB has more than 60,000 Continuous Emissions Monitoring Systems (CEMS) installed in over 100 countries that help monitor our environment,” said Stephen Gibbons, ABB’s Head of Product Management in Continuous Gas Analysers. “We draw on 60 years of experience in emissions monitoring to provide this support in concrete terms. CEMcaptain has been combined with innovations in on-site and remote digital services. The result is a solution that provides the industry with a digital toolbox that increases regulatory compliance and operational efficiency.”


Fast fault reporting, diagnosis and repair are achieved via the on-site and remote digital services which help operators get closer to 100 percent availability for their gas analysis instrumentation. Dynamic QR codes are integrated into the ABB CEMcaptain system display panel. All relevant diagnostic information can be collected from the analyser via a scanned code and transferred to ABB support. This means that maritime instrumentation technicians can send real-time information to an ABB service expert to get immediate guidance on appropriate maintenance. ABB Ability™ Remote Assistance with secured connectivity direct to ABB support is also offered for real-time solutions to problems. These features reduce the costly training of changing crews as well as the number of experts required on board. They also increase on-board safety by reducing crew exposure to emissions.


CEMcaptain GAA610-M is approved by all major classification societies (DNV GL, ABS Group, Lloyds Register, Bureau Veritas, ClassNK, Korean Register). For More Info, email:


54258pr@reply-direct.com


email: For More Info, email: email:


power generation.


The main applications for calibration of NO2 CEMS) monitoring and exhaust gas measurement.


instruments are for personal exposure gas monitoring, fixed area monitoring, emissions (EPA,


Personal Exposure Monitoring As the TWA and STEL values are so low, the requirement for nitrogen dioxide calibration gas for personal exposure gas monitoring has typically been either 5ppm or 10ppm. Nitrogen dioxide has been a challenging gas for many users of gas detection instruments as the highly reactive gas has an extremely short shelf life in smaller non-refillable cylinders (7 months). This creates issues with having the gas readily available for immediate requirements.


Quality Products • Applica�on Exper�se • On-Time Delivery


Smaller cylinders of 34L, 60L or 112L have been the norm for this application primarily because of the short shelf life. In most cases, customers ask for the smallest cylinder because of the shelf life.


Fortunately, CAC GAS & Instrumentation has two solutions available today which can assist in solving this issue.


Electronic gas generators Electronic gas generators provide gas concentrations of NO2


electrochemical cell which is long lasting. The same base unit can be used with other gas cells (CL2, CL02, HCN, H2 gas when they need it, even for very infrequent requirements.


down to as low .05ppm to 5ppm. Gas generators use an S),


providing flexibility for measuring other gases. Although an initial capital cost is required, they are very cost effective over time and provide a long-term solution. The electrochemical cell can be stored when not in use providing customers with NO2


Leaders in Specialty Gas Solu�ons.


Custom Gas Mixtures • Gas Control •


1300 CAC GAS +61 (0)2 8676 6500


CAC@CACGAS.COM.AU WWW.CACGAS.COM.AU


AET ANNUAL BUYERS’ GUIDE 2021 WWW.ENVIROTECH-ONLINE.COM Gas Generators White Top Specialty Gas Cylinder


The 36-month shelf life “white top” specialty gas mixture cylinder is an excellent solution for those customers with multiple instruments. High pressure cylinders are available in larger capacities of 900 and 4000 litres of gas. These cylinders are specifically treated and conditioned to provide stability over this extended shelf life. Based upon using only two litres of gas per monthly calibration, a customer would only need to have 10 instruments to consume 900 litres within the shelf life. That does not include bump testing/response testing which should be done daily.


These cylinders are also available for our EPA and CEMS standards providing long term environmental monitoring solutions for all NO2


applications.


As has been demonstrated, there are multiple options for calibrating and bump testing NO2 can meet customers specific requirements. For further information on our calibration gas solutions for NO2


application, contact CAC GAS & Instrumentation. More information online: ilmt.co/PL/apqj


For More Info, email: email:


For More Info, email: 54367pr@reply-direct.com


instruments and sensors which or any other


Calibration Gas Solutions for Measuring Nitrogen Dioxide Nitrogen dioxide (NO2


oxides include nitrous acid and nitric acid. NO2 The major cause of NO2


) is one of a group of highly reactive gases known as oxides of nitrogen or nitrogen oxides (NOx). Other nitrogen is used as the indicator for the larger group of nitrogen oxides.


in the air is a result of incomplete combustion of fossil fuels with the highest concentrations resulting from


diesel vehicles. Coal mining, buses and other diesel vehicles create the greatest hazard for ambient air exposure in mines, tunnels, and enclosed spaces such as repair garages. Also, NO2


along with nitric oxide, carbon dioxide and sulphur dioxide are all pollutants from


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72