24


Gas Detection Landfill Gas H2S Increase Measured with High-range Analysers


Hydrogen sulphide levels (H2S) in landfill gas have increased and Geotech (UK) has responded to changes reported by landfill site operators by now offering analysers measuring H2S up to 10,000 ppm. Rapidly rising H2S levels are thought to be caused by waste-to-landfill content changing largely as a result of success in recycling and other initiatives to avoid sending waste


to landfill. Previously, H2S was measured at 0-500ppm – still typical for post-scrubber H2S measurement – but higher level monitoring is now essential on many UK landfill sites.


Currently the two main methods of landfill gas measurement are either with portable or fixed-


position gas analysers. Geotech reports strong interest in high-range H2S analysis at 0-10,000 ppm which is an option on its newly launched portable landfill analyser, the GA5000 . This option is also available on the Geotech fixed-position, automated landfill and biogas gas analysers, the GA3000 and the Geotech AEMS system.


As well as presenting a significant health risk to operators, H2S can also ‘poison’ the electrochemical cells which provide the most cost-effective solution for H2S monitoring.


Higher H2S levels present a greater challenge. The cells must be regularly purged with clean air. Geotech’s portable analysers are easily purged manually after taking each reading and Geotech fixed position gas analysers purge automatically. Without purging, the life of the H2S cell is dramatically reduced and accuracy compromised. Some analyser systems dilute biogas with air in order to monitor H2S continuously but there is a significant danger of adding error with this approach and it may well not be enough to cope with new, high H2S levels.


For the many landfill operators using landfill gas to produce electricity from CHP engines, accurate H2S measurement is essential. To protect CHP engines, inbuilt gas content and quality sensors may cause auto-shut down to protect engines from corrosive H2S damage and CHP engine manufacturers usually specify an upper H2S limit above which warranties can be invalidated. Consequently, landfill operators often prefer to analyse the gas used in CHPs. If the gas is not suitable for CHP use and without an H2S scrubber, likely to cause damage with excessive H2S, they may divert it to flare or use it elsewhere.


High levels of H2S are often reduced with scrubbing systems and gas analysers can measure levels before and after scrubbing. This monitors scrubber performance as well as avoiding high levels of corrosive H2S reaching and damaging CHPs.


Geotech advises that all landfill gas analysers must be used and managed properly, including appropriate purging, to give operators the reliable gas


readings essential for gas field management. As H2S levels rise, so does the need for accurate, dependable landfill gas analysis. Geotech works closely with landfill operators and other stakeholders to ensure equipment is in-line with changing conditions as well as being reliable and well-supported.


Reader Reply Card No. 79


DOD Technologies Europe – represented by Solidsense GmbH (Germany) – has launched a new portable colorimetric detection device.


The Next Generation ChemLogic Portable (CLPX) provides powerful portable gas detection to meet a wide variety of applications. Its Improved Optics Design and Automated Optics Calibration makes the CLPX the most reliable, fool proof, user friendly gas detector on the market.


New Automated Gas Standards Generator


KIN-TEK’s (USA) new automated FlexStream™ gas standards generating system is now CE approved and available in Europe, offering total flexibility for creating precision gas mixtures. Mixtures are produced by diluting the emission from permeation tubes, or diffusion tubes with an inert diluent, typically nitrogen or zero air.


The FlexStream™ is ideally suited for creating trace concentration – ppm, ppb, and pptr – mixtures. An internal microprocessor sets the operating mode and automatically adjusts dilution flows to achieve desired concentrations.


The FlexStream™ can also be controlled remotely by a PC or process computer using Modbus connectivity. Using an external PC allows remote control of the FlexStream™, uploading QC methods that can run automatically, and evaluating ‘scenarios’ to aid in setting up the unit to create specific mixture concentration ranges.


Reader Reply Card No. 192


The CLPX is a versatile instrument that can be configured to detect a variety of gases, eliminating the need to purchase different instruments or different gas keys to sample different gases. Changing the instrument from detecting one gas to another requires a simple change of the cassette.


The CLPX uses DOD Technologies’ reliable ChemLogic tape technology to detect toxic gases and utilises the most advanced electronics and analysis software to meet the needs of health and safety professionals.


Reader Reply Card No. 80


New Colorimetric Instrument Offers Simple and Reliable Detection for a Wide Range of Gases


New Mobile Gas Monitoring Perimeter System


Oldham (France), an Industrial Scientific recently introduced the Mobile Perimeter System (MPS) IV. The MPS IV is a mobile gas monitoring platform that can be rapidly deployed for temporary or remote gas detection applications. It is solar powered, has onboard strobe and siren, and can be configured with wireless communication, making it a truly stand- alone mobile gas monitor.


“The MPS IV provides a unique solution for our customers who need to monitor for potentially dangerous gas levels in areas where conventional wired gas monitors are difficult or costly to install,” says Tom Cunningham, President, Oldham.


The MPS IV monitors up to four gas readings simultaneously and can transmit those readings wirelessly back to a primary alarm station. The monitoring platform is configurable with a convenient tripod mount, or it can be wall mounted, pole mounted or mounted using available magnetic mounting brackets


Reader Reply Card No. AET Annual Buyers’ Guide 2012 www.envirotech-online.com 81 Reader Reply Card No. 82


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100