Figure 3. The NMSU team: (left to right in front) Wanqin Yu, JoAnne M. Dupre, (behind) John E. Gustafson and Jesus A. Cuaron


E. coli strain DH5cx and four strains of Staphylococcus aureus (LP9, MM61, MM66, and MM66-4) were chosen for the study. All the bacterial cell samples were grown, harvested, and lyophilised by researchers at New Mexico State University. In total, 15 unidentified samples in disposable cuvettes were presented to the ARA team and they were told that the first five samples were unique and the remaining ten samples were replicates, two each, of the first five. LIBS spectra were collected by focusing pulses from a Q-switched Nd:YAG laser (1064 nm, 60 mJ/pulse, 10 Hz) into the open end of a cuvette contained within a Class II biological safety cabinet and sparking the pathogenic sample within.


Each spectra was the accumulation of ten spectra from the laser-induced plasma plumes, with the collection of each spectrum accurately delayed by 1 microsecond from the laser pulse and integrated on a 20 microsecond temporal scale. Because the sample identities were unknown and to mimic an analysis situation in which data are collected and not controlled for quality, all collected spectra were used in the analysis with no screening for spectral quality and no data preprocessing. A total of 1050 accumulated spectra (70 spectra datasets for each sample) over the entire spectral range of 205.42 to 1000 nm from individual samples were collected. The LIBS classification spectra from Sample B (E. coli) is shown in Figure 5. The units of the ordinate axis is detector counts.


By using chemometric analysis of the LIBS spectra in combination with an identification algorithm, the ten blind samples were correctly matched to the unique samples thus demonstrating the spectral identification of all five bacterial samples with 100% accuracy.


The iStar Intensified CCD camera is perfectly adapted to cope with these challenging LIBS measurements, equipped with a fully integrated, software- controlled digital delay and ultrafast and ultralow jitter electronics for sub-2ns to ms optical shuttering capabilities. Coupled with the Echelle spectrograph, the camera delivers the highest spectral and time resolution across a very large bandwidth.


A new generation of rapid, automated biosensor detection systems?


This study demonstrates that LIBS can be used to differentiate the common hospital-borne bacterial pathogens, E. coli and S. aureus in pure form in less than a minute with 100% accuracy using only the raw LIBS spectra in an automated system. Furthermore, in combination with appropriately constructed chemometric models and defined testing flows, LIBS could be used to successfully classify an unknown pathogen in pure form, both species and strain, provided the unknown pathogen is within a defined set of pathogens. In medical treatment applications, by classifying pathogens in matrices of interest (such as blood or tissue), this capability could possibly be used to create testing algorithms to assist in rapid pathogen identification, thereby speeding the initiation of an appropriate antimicrobial-therapeutic regimen.


Figure 5. LIBS classification spectra from E. coli


Figure 4. LIBS setup at ARA: (A) Nd:YAG laser, (B) laser focusing optics, (C) biological target in Class II safety cabinet, (D) collection fibre optics, (E) Echelle spectrometer, (F) Andor iStar ICCD


As a ‘proof-of-principle’ for a LIBS-based instrument for rapid pathogen detection, these are important results since LIBS has many advantages as a biosensing method which include: little or no sample preparation; simplicity of use (focus the laser pulse on the material and collect the light); and rapid in situ analysis with results in less than a minute with automated analysis.


The potential for saving lives through the development of rapid diagnostic instrumentation that can be operated by personnel without any specific technical or LIBS expertise should not be underestimated.


References


1. Baudelet, M, Yu, J, Bossu, M, Jovelet, J. and Wolf, J. P. ’Discrimination of Microbiological Samples using Femtosecond Laser-Induced Breakdown Spectroscopy’, Applied Physics Letters 89, 163903 (2006)


2. Multari, R. A, Cremers, D.A, Dupre, J. M. and Gustafson, J. E. ‘The Use of Laser-Induced Breakdown Spectroscopy for Distinguishing Between Bacterial Pathogen Species and Strains’, Applied Spectroscopy 64 (7), 750-759 (2010)


Authors


a) Applied Research Associates, Southwest Division, 4300 San Mateo Blvd, NE, Suite A-220, Albuquerque, NM 87110, USA b) NetDyaLog Limited, The Annexe, Crispin Way, Farnham Common, Bucks, SL2 3UE, UK


Camera Technology Debuts at Daytona 500


FLIR Advanced Thermal Solutions has developed a state-of-the-art IR camera system called the 'Heat Seeker' that has enabled broadcaster - Fox Sports to record the extreme temperatures which develop on NASCAR motor vehicles during their recent Daytona 500 live broadcast. The thermal images are of particular interest as cars running in the rear of a piggy-backed pair lose air flow while drafting and must eventually switch places with the lead car to avoid overheating their engine. The technology can also reveal the on-track groove cars are using, as well as the difference between tyres about to be changed compared to fresh replacements. FLIR cameras were featured in three live segments during the Daytona 500 race: one segment that compared a hot tyre just taken of a car to a cold tyre sitting in the pits, the second segment compared the hoods of two cars during the race, and the final segment showed a blown out tyre just after being removed from a car late in the race.


FLIR supplied two of its SC8300 HD thermal cameras to Fox Sports to enable it to cover the race. One camera was configured to be portable and used by a roving Fox camera man in the pits. The other camera was mounted on a tripod at Turn 4 approximately 100 feet from the track. The pit camera was used to acquire thermal images of the activity in the pits and the Turn 4 camera was used to take video of the cars as they passed by at over 200mph. Every day researchers throughout the world are looking for new methods to help them solving their scientific questions. Thermal imaging using IR cameras’ has proven to be an invaluable tool to solve a wide variety of scientific problems based on heat and temperature measurement. Because of its non-intrusive analysis capacity, thermal imaging systems have become indispensable instruments for a wide variety of research and development applications.


Circle no. 430


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48