This page contains a Flash digital edition of a book.
Product News


ZEISS Presents New Axio Observer Microscopes for Life Sciences


The ZEISS Axio Observer family consists of three stable and modular microscope stands for flexible and effi cient imaging that combines the proven quality of ZEISS optics with new automation features. Among these features is Autocorr , which allows adaption of immersion objectives to varying conditions with concomitant


correction of spherical aberrations. Another is the new Autoimmersion option, which maintains stable water immersion. Also included is Defi nite Focus.2 , a novel hardware focus that automatically compen- sates for focus driſt .


ZEISS Microscopy www.zeiss.com/microscopy


PicoQuant Combines Fluorescence Spectroscopy and Microscopy


The recently developed fiber coupling sample holder for PicoQuant’s time-resolved spectrometer FluoTime 300 makes it possible to interface the system with a microscope such as the MicroTime 100. T is setup easily allows users to record time- and space-


resolved emission spectra from any sample mounted in the microscope. Expanding the capabilities of a spectrometer with a microscope provides exciting opportunities for investigating the spatial dependence of luminescence behavior in a large variety of samples.


PicoQuant GmbH www.picoquant.com


Controlled, Accurate Plasma Cleaner for TEM Sample Preparation


T e HPT-100 TEMCLEAN is a bench-top glow discharge system that is suited to the routine cleaning of TEM sample holders/ grids; it also cleans and prepares other individual items. The system features interchangeable re-entrant style adapters


for JEOL and FEI sample holders, as well as a removable parts carrier that can accommodate up to ten 25 × 75 mm glass microscope slides. Operation is via a color touchscreen interface that controls the cleaning cycle.


Henniker Plasma www.plasmatreatment.co.uk


Finger Lakes Instrumentation Launches INCITE Cube Switcher


INCITE switches dichroics 10 times faster than traditional cube turrets. It changes dichroics and emission fi lters in 30 ms, and it replaces the stock turret in Nikon Eclipse series microscopes and synchronizes seamlessly with


other system components. INCITE is especially suitable for live-cell imaging, multi-channel fluorescence, high-content screening, and multi-modal imaging. INCITE builds on FLI’s track record of designing the fastest microscopy motion components available and collaborating with industry partners on custom solutions.


Finger Lakes Instrumentation www.fl icamera.com


2017 January • www.microscopy-today.com


Leica Microsystems Paves the Way to Access Imaging Beyond the Diffraction Limit


With the Super-Resolution Technology HyVolution 2 and the Leica TCS SP8 STED ONE Nanoscope, Leica Microsystems expands its product portfolio for light microscopy having resolution beyond the diff raction limit. With the HyVolution 2 Super-Resolution Technology allowing resolution down to 140 nanometers,


processes and structures can be resolved in several colors simultaneously with high acquisition speed and high signal-to-noise ratio.


Leica Microsystems GmbH www.leica-microsystems.com/products/confocal-microscopes/details/ product/hyvolution-2/


Olympus DP74 Color Microscope Camera Provides Intelligent Real-Time and Fluorescence Imaging


T e new Olympus DP74 color fl uorescence microscope camera combines advanced image processing technology, a low-noise design, and easy-to-use soſt ware to deliver smooth, true-to-life images in demanding life science and industrial applications. T e features of the DP74 microscope camera


and intuitive workfl ow enhancements make it easy to capture realistic, high-quality images. T e DP74 camera off ers one of the widest fi elds of view currently available with a wide 16:10 aspect ratio.


Olympus Corporation www.olympus-lifescience.com


Semiconductor Inspection Microscope Stage


T e H116 stepper stage from Prior Scientifi c can accommodate 200 mm wafers, making it perfect for performing scanning of a wide range of semiconductor wafers and similar specimens. Off ering a travel range of over 255 × 216 mm, the large-area scanning capability of the H116 stage


is exceptionally precise, with a minimum step size of 0.04 microns and a repeatability of ±0.7 microns. T e accuracy of the H116 stage, enhanced by Prior’s Intelligent Scanning Technology (IST), is unmatched.


Prior Scientifi c Instruments Ltd www.prior-scientifi c.co.uk/Products/Motorized-Stages/H116.aspx?fi d=2


New Vacuum Storage Solution for FIB, SEM, and TEM Samples


EM Resolutions announces the EM-Storr vacuum sample storage container, developed to protect EM samples under vacuum storage and transportation. It is available in versions for TEM grids, FIB half grids, SEM stubs of various types, and other valuable EM samples, protecting them from air, moisture, and dust. An added advantage is EM-Storr containers


can be stacked on top of each other saving valuable space in the EM laboratory.


EM Resolutions Limited www.emresolutions.com/em-storr-vacuum-sample-storage-container


53


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68