This page contains a Flash digital edition of a book.
ECO Commercial Evaporators
CTE Ceiling Evaporators
(TÜV Approved to ENV 328)
The CTE range of unit coolers is suitable for installation in cold rooms for the preservation of fresh or frozen products.
The compact size of the unit allows to make maximum use of the storage space of the cold room in which it is
installed.
The entire range is equipped with high efficiency coils made from special profile aluminium fins and inner grooved
copper tube, suitable for the new generation refrigerants.
According to the room temperature the range is divided as follows:
CTE H3 for higher temperatures
(> +2 °C) with 3,5 mm fin spacing;
CTE H4 for higher temperatures
(> +2 °C) with 4,0 mm fin spacing;
CTE M6 for medium temperatures
(> -15 °C) with 6,0 mm fin spacing, electric defrost version (ED) is recommended;
CTE L8 for lower temperatures
(> -35 °C) with 8,5 mm fin spacing, equipped with electric defrost (ED).
This range employs three types of standard fan motors:
A) diameter 250 mm, shaded pole single-phase 230V/1/50-60 Hz with fibre-glass charged polyamide fan guards.
B) 315 mm diameter, external rotor single-phase 230V/1/50-60 Hz with built-in electric capacitor and epoxy coated steel fan guard.
C) 350 mm diameter, external rotor single-phase 230V/1/50-60 Hz with built-in electric capacitor and epoxy coated steel fan guard.
D) 500mm diameter, external rotor three-phase 400V/3/50-60Hz with epoxy coated steel fan guard.
The standard fan motors employed have the following features:
IP 44 protection grade; (IP54 for 500mm)
class B insulation; (F for 350mm - 500mm)
internal thermal contact protection;
operating temp. -35 °C - +40 °C.
The versions with standard electric defrost (ED) are equipped with stainless steel heaters with vulcanised terminals preset for
400V/3/50-60Hz connection.
The electric parts and casework are connected to a grounding terminal, the wiring of the motors and heaters is
carried out in separate IP 54 protection grade junction boxes.
For special applications such as C0
2
and further information consult our technical department
Please check with our sales department for lead times, some of these coolers are made to order.
Model Identification
CTE Ø250/315mm
CTE 349 H3 ED W9
Product identifaction
Model identification code
Fin spacing code
Electric defrost version brine coolers only
CTE Ø350/500mm
CTE 35 2 A 8 ED W9
Product identifaction
Fan diameter 35 = 350mm 50 = 500
Brine coolers only
Number of fans
Electric defrost version
Heat exchange reference
Fin spacing code
1
The weight refers to models with ED electric defrost.
X Use thermostatic valve with external pressure equalizer.
7
Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56