Laboratory Products 13
High Quality Sterile Scoops Ideal for Sampling and Dispensing
Sampling Systems Ltd is a major manufacturer of sampling devices and associated equipment. These devices are used extensively in the
pharmaceutical and food industries as well as the chemical, cosmetic and other hygienic industries.
Sampling Systems’ PharmaScoops®
are made from
a variety of materials. They are available in white, red or blue and are manufactured in a medical cleanroom.
The scoops are manufactured using FDA, EC 1935/2004 and EU 10/2011 conforming materials and are BSE/TSE free. They are available pre- sterilised or non-sterilised.
PharmaScoop® features include: sizes from 30ml to 2500ml; ideal for single
use, sterile or non-sterile; available in red, white or blue; materials available are polystyrene, polypropylene and high density polyethylene; comfortable ergonomic design; individually wrapped; suitable for use in ATEX zones 0,1 & 2.
For a complete listing of available sizes, colours and materials, go to
www.sampling.com.
43203pr@reply-direct.com New and Innovative Chromatography Media
Since 1911 MACHEREY-NAGEL stands for innovation, high quality and reliability in analytical chemistry and life science. MN offers a broad range of products for chromatography, fi ltration, rapid tests, water analysis and bioanalysis as one of today’s leading manufacturers in these fi elds. MN´s expertise in manufacturing of chromatography media is based on many years of experience in silica technology. The development of the spherical HPLC silica NUCLEOSIL®
and the introduction of
commercially available ready-to-use TLC plates and sheets are just two milestones emphasising the pioneering tasks of MN in promoting these separation techniques, which today are omnipresent in analytical labs all over the world.
In September 2017 MN introduced their latest development for solid-phase extraction – CHROMABOND® HLB. This hydrophilic-lipophilic balanced polymeric SPE adsorbent is specially designed for the enrichment
of hydrophilic analytes from polar matrices like water, blood serum or food. With classical C18/C8 modifi ed silica, even with modern hydrophobic polymer adsorbents, retention is often diffi cult. Linked hydrophilic groups of the HLB copolymer interact with polar functional groups of the analytes while the lipophilic backbone interacts with nonpolar hydrocarbon residues to provide enhanced retention. A broad range of columns, cartridges and 96-well plates packed with CHROMABOND®
The latest launches, CHROMABOND® PL for the removal of phospholipids and CHROMABOND®
media. For more information, visit
www.mn-net.com/SPE. The hydrophobic HPLC phase NUCLEODUR®
C18
HLB adsorbent can be applied for a wide range of applications (e.g., pesticides from water, pharmaceuticals from serum, antibiotics from honey). Carbon A for analysing acrylamide in drinking water, complement the steadily growing range of innovative SPE
Gravity-SB with its distinct polar selectivity is ideal for method development, because it shows better retention of early eluting compounds. Overall sophisticated
analytical separations, especially for polar compounds (e.g., antibiotics, water-soluble vitamins, organic acids), are recommended applications. The recently introduced biphenyl phase NUCLEODUR® TT2
separation mode of the HPLC phase is based on two retention mechanisms – TT
In order to meet the growing demands on saving analysis time and solvent costs, MACHEREY-NAGEL expanded the portfolio by adding core-shell silica phases with 2.7 and 5 µm particle size. NUCLEOSHELL®
reversed phase and
HILIC columns enable signifi cantly shorter run times at moderate column back pressures and set new effi ciency standards in research and quality control. For more information, visit
www.mn-net.com/HPLC.
But can thin-layer chromatography be innovative? For about 50 years MACHEREY-NAGEL has been manufacturing glass plates, as well as aluminium and plastic sheets coated with silica gels and other adsorbents for TLC and HPTLC. Until today, the glass plates SIL G-25 with and without UV indicator as well as the ALUGRAM®
Xtra SIL G aluminium sheets
are very important TLC products which are often used in scientifi c laboratories, but also in clinical, pharmaceutical, natural product and food analyses.
Yes, TLC can be innovative. The application of large volumes of very dilute samples can cause irregular spreading of substance spots, which complicates evaluation. The innovative TLC glass plates SILGUR-25 and the aluminium sheets ALUGRAM®
Xtra SILGUR
– silica-coated plates or sheets with a concentrating zone of inactive kieselguhr – solve this problem by concentrating sample spots on the layer.
The latest TLC development, Channel-Plates SILGUR- 25-C UV254
ww.mn-net.com www.mn-net.com
· Neumann-Neander-Str. 6–8 · 52355 Düren · Deutschland DE / International:
CH:
001: 2008 FIZIERT
+41 62 388 55 00 +41 62 388 55 05
il:
sales-ch@mn-net.com
Tel.: +49 24 21 969-0 Fax: +49 24 21 969-199 E-Mail:
info@mn-net.com
A wide range of approved and of new application notes are freely accessible online
www.mn-net.com/apps.
Tel.: +33 388 68 22 68 Fax: +33 388 51 76 88 E-Mail:
sales-fr@mn-net.com
EN ISO 9001: 2008 ZERTIFIZIERT
Tel.: +41 62 388 55 00 Fax: +41 62 388 55 05 E-Mail:
sales-ch@mn-net.com
Tel.: +49 24 21 969-0 Fax: +49 24 21 969-199 E-Mail:
info@mn-net.com
Tel.: +33 388 68 22 68 Fax: +33 388 51 76 88 E-Mail:
sales-fr@mn-net.com
Tel.: +41 62 388 55 00 Fax: +41 62 388 55 05 E-Mail:
sales-ch@mn-net.com
44021pr@reply-direct.com
MACHEREY-NAGEL GmbH & Co. KG · Neumann-Neander-Str. 6–8 · 52355 Düren · Deutschland FR:
FR: CH:
with 19 channels, helps to prevent cross contamination by sectioning several samples. More samples can be separated on a plate, and spot areas can be more easily determined. For more information, visit
www.mn-net.com/TLC.
FR: Find what you are looking for! interactions and hydrophobic interactions.
, provides new options to improve selectivity for aromatic and unsaturated compounds (e.g., steroids, sulfonamides, tetracyclines). The innovative -TT
Water Purifi cation Units Save Water and Energy
Suez Water UK has responded to increasing laboratory interest in sustainable solutions by introducing ECO options for its popular Select water purifi cation systems. In addition to saving electricity with an intelligent stand-by feature, customers can now save water through high recovery reverse osmosis (RO) systems.
Recovery rates in similar RO-based systems can sometimes be as low as 10%. In other words to produce 5 litres of purifi ed water, up to 50 litres of feed water would be required, with 45 litres being run to drain as waste. By re-engineering the drain fl ow hydraulics and in conjunction with state of the art high recovery membrane technology, Suez Water UK has developed RO systems that can increase recovery rates to around 50%. This small modifi cation can be made retrospectively as part of a service visit.
The intelligent standby option, available on selected models, imposes a sleep mode on the purifi cation unit whenever a set time has elapsed without water being dispensed. During standby, a 10-minute recirculation programme takes place every 2 hours to maintain water quality. The benefi ts of this feature are savings on electricity usage and water wastage.
Further information on these features and their potential savings is available in a Suez white paper: Sustainable Laboratory Water Purifi cation Systems. To calculate the savings made possible by its ECO recovery and intelligent standby options, Suez is inviting labs to submit their own kWh electricity tariff and pence per m3
water tariff, along with the daily operating hours and water usage of their purifi cation units. There is also an offer from Suez to carry out water purifi cation audits on site.
“Laboratories are looking ever more closely at their operations to fi nd new ways of minimising environmental impacts,” said Steve Mines, Sales Director – Water Purifi cation Systems at Suez Water UK. “With our new ECO recovery and intelligent standby options we can help them save water, electricity and money in a very quick and straightforward way.”
43959pr@reply-direct.com ADVERTORIAL
MACHEREY-NAGEL Manufacturer of premium chromatography media
n CHROMABOND® SPE columns
n NUCLEOSIL®, NUCLEODUR® and NUCLEOSHELL® HPLC columns
n TLC plates and sheets
MACHEREY-NAGEL GmbH & Co. KG · Neumann-Neander-Str. 6–8 · 52355 Düren · Deutschland DE / International:
Tel.: +33 388 68 22 68 Fax: +33 388 51 76 88 E-Mail:
sales-fr@mn-net.com
www.mn-net.com
www.mn-net.com www.mn-net.com
7046ad@reply-direct.com
WWW.LABMATE-ONLINE.COM
Chromatography
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44