Environmental Analysis 23


New Temperature Calibration Systems for Infrared and Probe Thermometers


In a relaunch and upgrading of their CS series calibration sources, the NEW enhanced CS Series from Eurolec (Ireland) comprises of three dry block models for calibration with a temperature control system and a pocket for a reference thermometer. A selection of probe holes at the rear provide a choice of probe diameters for contact/probe thermometer accuracy checking and the ‘black body’ at the front provides a means of checking infrared non-contact thermometers. Both probe and infrared thermometers can be checked at the same temperature, at the same time without having to change inserts thus providing significant savings in time and inconvenience. Model CS173 features a range of +30.0 to +199.0°C and models CS174 & CS175 feature a range of 40.0°C below ambient (approx. -20°C) to +85.0°C.


In addition, all models feature a 2 position Precision Accuracy Check (PAC) function where at the touch of a switch, the accuracy of the


unit is confirmed at 2 preset points. All models also include an RS232 output socket – USB output is an option. Model CS175 features 0.01C resolution and± 0.05C accuracy. Precision reference thermometers RT162 or PC Temp RT2 kits with 0.01C resolution are recommended for use in conjunction with the CS series. These thermometer kits are supplied complete with a System Calibration Certificate traceable to UKAS.


Reader Reply Card no 74


For immediate information on products featured in this issue. Please email us today! info@iet-pub.com


Video Introduction to Sample Solvent Evaporation...


Genevac (UK) has announced a new online video demonstrating the ease of use and operational versatility offered by its Rocket™ Evaporator.


Presented as a Flash media presentation (www.genevac.com/movie/rocket/) the new video includes an informative introduction to the revolutionary evaporation technology used by the Rocket. Following this the viewer is seamlessly guided through the system operation - from the wide range of compatible sample holders for drying and concentration, loading


samples, ease of operation, stored method programming through to proprietary Genevac innovations that ensure sample integrity.


Benefiting from a patented low temperature, low pressure steam heating technology - the Rocket Evaporator is able to uniquely achieve the dual goals of very fast evaporation with very precise temperature control thereby accelerating the safe concentration or drying of samples. Developed in response to user requests for an evaporator that could quickly process larger volumes of solvent in parallel and without supervision, the Rocket Evaporator is designed to dry or concentrate six flasks, each containing up to 450ml of solvent. For scientists looking to concentrate extracted samples prior to analysis - the new Puck sampling accessory extends the sampling versatility of a Rocket Evaporator to simultaneously accommodate up to eighteen 60ml Accelerated Solvent Extractor (ASE®


) tubes. Offering true unattended


operation capability the Rocket Evaporator requires no training, even a beginner can competently use the system in less than 5 minutes. A 2-stage cold trap built into the Rocket Evaporator provides very high levels of solvent recovery, even with volatile organic solvents. In addition Genevac’s patented Dri-Pure®


technology prevents solvent bumping and cross contamination inherent with rotary evaporator and other vacuum evaporation systems. Requiring no peripherals for operation the compact Rocket Evaporator fits neatly onto a laboratory bench or into a fume hood. All key components on the robust and reliable system are user serviceable ensuring a low the cost of ownership.


Reader Reply Card no 75 High Quality Load Cells Now in Stock


Omega (UK) recognises that not only do customers want the highest quality load cells, but that they also need them quickly! That’s why we have made a significant stock investment at our European Headquarters in Manchester UK.


We have an extensive range of shear beam, tension link, though hole and low profile load cells in stock. This is an important development in enabling customers throughout Europe to have next day delivery of off-the-shelf, rugged, metric load cells.


Omega is committed to providing the highest quality products and has over 25 years of experience in the design and manufacture of load cells, with each device supplied with a traceable certificate.


Furthermore our Engineers can provide the solutions to your problems. We provide product selection and guidance, as well as full technical and after sales support.


Reader Reply Card no 76


Web-based Selector Tool for ICP Instrumentation


Teledyne Leeman Labs (USA) announces a web-based selector tool for ICP instrumentation.


Are you puzzled by which ICP is right for your application? No need to be. Teledyne Leeman Labs helps you find the best instrument configuration for your sample type. Visit their website to use the New ICP Selector at http://www.leemanlabs.com/ICP_Selector/icp.aspx. Just answer a few questions and find out which ICP configuration (e.g., axial, radial, dual view, array detector, or PMT) is the perfect fit.


Reader Reply Card no 77


: +43 7235 605 0 · F: +43 7235 605 8 info@epluse.cominfo@epluse.com · www.epluse.com


A-4209 Engerwitzdorf T: +43 7235 605 0


A-4209 Engerwitzdorf


F: +43 7235 605 8 www.epluse.com


Reader Reply Card no 78


ISO TS16949:2009 certified


ISO TS16 ISO 9


ISO 9001:2008


9001:2008 6949:2009


· Austr a Austriai


 E+E operates an calibra


E+E operates an accredited-by-state calibration laboratory and holds "Austria's National Standard for


National Standard for Humidity"


 E+Esensor technology weather institutes


E+E sensor technology is used by nationalis used by national weather institutes worldwide


worldwide


 Relative Humidity DewPoint Te


and ±0.2°C (±0.36°F)


Relative Humidity  Dew Point TemperatureTempera  Air Temperature


re


Air Temperature  best accuracy ±1.3% RH


best accuracy ±1.3% RH and ±0.2°C (±0.36°F)


proven long term stability  high reliability due to uniqueih gh reliability due to u


 proven long term sta


sensor protection coating  heated probe technol heated probe technology


sensor protection coat for best performance


 traceable calibration certificate


traceable calibration certificate


ting


for best performance near condensation


near ogy


nique bility


rature


Meteorology


Meteorology RH / Td / T


ration laboratory ry


November/December 2010


IET


Sensor TechnologyTechnology Sensor Te


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60