Flow Level Pressure Diagnostic Technology Expanded on Series of Flow, Level and Pressure Instrumentation Emerson Process Management has expanded its Advanced HART® Diagnostics Suite on the Rosemount® 3051S Series of Instrumentation for pressure, flow and level


measurement. New features expand diagnostic coverage beyond transmitter electronics to identify and prevent abnormal process and installation issues. The new Power Advisory Diagnostic helps ensure the integrity of the electrical loop by detecting unwanted changing electrical conditions, such as water in the


terminal housing, ground loop issues, corrosion of terminals, or an unstable power supply. The Advanced HART Diagnostics Suite also includes Statistical Process Monitoring technology, to measure and analyse previously unseen process noise, providing intelligent process insight. This has led to a significant expansion in the range of process diagnostic applications such as detection of furnace flame instability, incipient distillation column flooding, and valve or pump cavitation.


“The expanded capabilities of Advanced Diagnostics on the Rosemount 3051S gives plant personnel additional insight into their facilities – insight they can use to make


informed decisions that will optimise the availability, efficiency and reliability of their plants,” said Dave Wehrs, Vice President of pressure design and engineering for the Rosemount division of Emerson Process Management.


The Rosemount 3051S with Advanced Diagnostics was put through the rigorous IEC 61508 safety certification process by exida, resulting in an industry- leading Safe Failure Fraction of 96.8%. Safety can be further improved by utilising Power Advisory Diagnostic and Statistical Process Monitoring to uncover previously undetectable failures of the electrical loop and in the process connection, including plugged impulse lines. Combining the highest safety-rated pressure transmitter in the industry with advanced diagnostics enables 10-year proof test intervals and the safest installation possible.


“The end result of having equipment with low failure rate and high diagnostic coverage is not just improved safety but also lower downtime,” said Dr. William Goble, principal partner of exida.


The Rosemount 3051S Series of Instrumentation is part of Emerson’s broad range of intelligent, digital field devices that power the PlantWeb™ architecture. Further cost savings, increased plant availability, and enhanced safety and environmental compliance are achieved when the transmitters are integrated into the PlantWeb digital plant architecture.


Reader Reply Card No New Website for Tank Level Measurement


TMS, Inc. (USA) recently launched a new website (www.levelcom.net.) for its LevelCom line of Tank Level Indicators and Controllers. The LevelCom LC-100 Tank Level Indicator uses advanced bubbler technology. The LC-100 combines pulsed pneumatic depth sensing technology with features that include: SCADA interface; Modbus connectivity (Devicenet & Profibus Available); self diagnostic software and output relays for control or remote alarms. The LC-100 is field configurable, for weight, volume measurement and specific gravity. The LC-100 Tank Level Indicator is a rugged and dependable with a long service life.


Reader Reply Card No New Industrial Body Flowmeters Dwyer Instruments, Inc., (USA) has announced the release of its new Series P72 Flowmeters.


The Series P72 Flowmeters are heavy bodied meters for corrosives, gases, and high purity fluids. These meters are designed specifically for demanding applications. They are economically priced meters ideal for caustic solutions as well as liquid chlorine, sodium hypochlorite and chlorine gas. The Series P72 Flowmeters are suited for water treatment facilities that deal with these aggressive types of gases and fluids. The P72-A is comprised of P72 and polysulfone, while the P72-B has all P72 wetted components for maximum corrosion resistance. Units have a full-scale accuracy of ±2% and can be disassembled quickly without the meter being removed from the pipeline for easy cleaning. The Series P72 Flowmeters are available with standard 3/4˝, 1-1/2˝, 3˝, and 4˝ flange connections. Optional NPT connections are also available.


Reader Reply Card No


BETA Pressure & Temperature Switches for Industry


177 176 174


55


LeadingtheWorld


Total & Interface Level Measurement Solutions


K-TEK’s KM26 Magnetic Level Gauge can be used in the most demanding process applications up to 4500 psig and 1000 oF.


The unique extruded outlet process connections and precis- ion engineered float have provided our customers with years of maintenance free operation and a new standard of perform- ance. With over 400,000 global installations, K-TEK’s is preferred by many process engineers around the world!


BETA has obtained a SIL 2 / IEC 61508 certification for the complete User Friendly range of switches. After designing and manufacturing pressure switches since 1971, the BETA Pressure & Temperature switch have received a SIL2 ( Safety Integrity Level ) rating.


The SIL 2 Certification was issued by Exida and indicates the safety performance for operational reliability and risk reduction of the BETA Pressure and Temperature switches.


The Piston / Diaphragm design of the BETA switch shows inherent benefits for performance and reliability for the Oil & Gas and related industries.


The assessment report is available from the website at: http://www.beta-b.nl/downloads/index.php


K-TEK BV


Verrijn Stuartlaan 22, 2288 EL Rijswijk, The Netherlands Tel.: + 31 (0)70 7531 800 Fax: + 31 (0)70 7531 890 E-mail: sales@k-tek.nl


Reader Reply Card No 208 Reader Reply Card No 178 Annual Buyers’ Guide 2011 The Leader in Level Detection


Let


assist you with your


next Level measurement solution, call us on +31 (0)70 7531 800 Or e-mail us at sales@k-tek.nl Or visit our website at www.k-tek.nl


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102  |  Page 103  |  Page 104  |  Page 105  |  Page 106  |  Page 107  |  Page 108