Safety
New Network Survey Software Offers Traceability and User-Friendliness
New safety legislation in Europe requires gas distribution companies to monitor their networks on a regular basis (once, twice or three times a year depending on the country). As a result, they are under an increasing obligation to guarantee traceability of their surveys by providing precise location and dating of gas concentrations measured.
Systematic leak detection is therefore part of the overall safety policy of gas distribution companies vis-à-vis the community and their own
workforce. Aimed at the early identification of any deterioration of the network, systematic leak detection enables timely remedial action. But network surveys are also part of any maintenance policy, with the dual aim of increased safety and operating efficiency.
Gazomat™ S.A.R.L. (France), a company of T.D. Williamson, Inc. (France) manufactures a whole range of equipments used for network inspections both from vehicle and on-foot. The devices integrate the proprietary Inspectra® selectivity to methane.
Laser system that offers 1 ppm sensitivity and a total
Eager to meet gas companies’ traceability requirements, Gazomat™ introduces a new survey software. Designed to ensure total traceability of network monitoring, both from vehicles and on-foot, the NGS software controls the whole measurement system and provides :
This software offers real-time visualisation on the downloaded road map of the operator’s position and the survey mission’s progress, plus any gas concentration detected. In addition; users will enjoy the permanent saving of key survey data, such as concentrations measured, associated GPS coordinates, precise address on the map and operator comments. An interactive and simplified interface with the operator, including pop-up windows and easy-to-understand graphics to guide the operator throughout the mission is also part of this software package. A GPS type mapping system – the software integrates a GPS type map, which gas companies can supplement further with building or pipeline network maps in SHAPE format, a standard format used worldwide is also included.
• A final survey report in PDF format compiling the information on the survey mission, as well as all events recorded during the mission plus functional tests of the measurement equipment. Reader Reply Card No 100 Years of Experience Creates the Latest in IR Sensor Technology
For more than 100 years, Oldham from Industrial Scientific has specialised in safety and more particularly in gas and fire detection. The company offers a wide range of single gas and multi-gas portable detectors, fixed transmitters and controllers. Their products are always application-driven and solution-oriented. Whether for a single application or multiple rooms and areas, our monitoring solutions have been developed to meet the unique needs of our customers.
Oldham’s Research and Development department designs equipment that meets the latest international standards. They are dedicated to developing gas sensors, detectors and control units that meet or exceed these requirements.
The company’s latest fixed monitoring solution combines the OLCT100, OLCT80 and OLCT60 gas detectors with the XP IR infrared sensor. This completes the Oldham line of fixed systems.
This new patented IR sensor from Oldham makes the OLCT100 XP IR one of the best and most reliable infrared detectors on the market. Infrared detection technology offers significant advantages when compared to catalytic detectors:
This sensor offers fail safe technology: optical detectors continuously control the intensity of infrared light sources. This intensity is maximal in the absence of gas, so any decrease in intensity will indicate that gas is present! XP IR requires far less maintenance than competing sensors, it is also immune to poisons, has a very long life expectancy and can operate in oxygen deficient atmospheres.
The OLCT100 XP IR was also developed to conform to the safety standards IEC 61508 and EN 50402. This means that the complete component design process has been analysed, verified and validated (including specifications definition, design methods, design tools, testing methods, review techniques and documentation).
As a result, the OLCT100 XP IR is SIL 2 certified according to IEC 61508 / to EN 50402 (EN 50502 is an European derivative standard from the generic IEC 61508: Electrical apparatus for the detection and measurement of combustible or toxic gases or vapours or of oxygen – Requirements on the functional safety of fixed gas detection systems). And, its Probability of Failure on Demand (PFD) is 0.35 10-3 with a yearly interval maintenance test.
With a century of expertise behind them, Oldham offers a wide variety of other helpful support services. Their highly professional, yet friendly, staff are always on hand to answer whatever technical questions you may have.
Reader Reply Card No 124 Chlorine Gas: Danger and Detection
Properly installed, reliable gas detection can help prevent chlorine-related injury or death. In the workplace where chlorine is part of the process, fixed gas detection is the first line of defense for early warning of chlorine leaks and for changes to specific processes to stem and stop the leak.
Detector Electronics’ (USA) GT3000 chlorine gas detector’s electrochemical cell has a range of 0-10ppm and performance verified to FM6340. The GT3000 can be installed as a stand-alone device with 4-20mA output with
HART protocol, local LED indicators, and magnetic calibration. Or the sensor/transmitter can be combined with a local or remote display, such as the Det-Tronics’ FlexVu Universal Display.
Detector Electronics offer a new application note which illustrates considerations for detecting chlorine gas in a wide variety of applications.
Reader Reply Card No 125 GasScreen 160
Control Unit for 16 channels 4-20mA and/or 256s points RS485
123
43
Fixed Gas Detection Systems
For continuous monitoring of combustible, toxic gases and oxygen. Complete range of sensors / transmitters ATEX approved DNV and RINA marked products for marine applications.
Explorer Box 2ch
2 channels wall mount control unit with touch display
GasPoint
Stand alone single gas detector
Eexd Gas Detectors
For flammable gases (%LEL), Oxygen (% O2), and toxic gases (ppm).
Via Pietro Chiesa, 25 r. - 16149 Genova
Tel. (+39) 010-469.56.61 r.a. • Fax (+39) 010.642.42.05 email:
info@recomind.com • web:
www.recomindustriale.com
Reader Reply Card No 126
Annual Buyers’ Guide 2011
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96 |
Page 97 |
Page 98 |
Page 99 |
Page 100 |
Page 101 |
Page 102 |
Page 103 |
Page 104 |
Page 105 |
Page 106 |
Page 107 |
Page 108