Chromatography 15 No Frills HPLC Autosampler Delivers What You Truly Need
IF your HPLC routine calling for automation, look no further than the HT1500L: an autosampler specifi cally designed for HPLC, fully equipped with all the powerful features any HPLC technician would naturally choose.
HT15000L is the new HPLC autosampler from HTA that offers the best balance of quality and affordability and that is perfectly compatible with any HPLC system.
Unlike LC-MS, nanoLC and UHPLC systems, the HPLC requires few, essential features: excellent analytical performance, good sample capacity, and of course, uncompromised reliability, robustness and durability. HTA has showered the HT1500L with all these essential features, while eliminating anything unnecessary to keep costs as a minimum.
No frills but even no compromise. Despite the competitive price, HT1500L has a strong commitment to quality: the materials have been picked up to provide longevity; the up-to-date technologies offer reliability that deserve a modern instrument while the design attests our care in details.
HT1500L holds multiple racks, each of them removable, to allow continuous sample feeding and more convenient operations. The on-board solvent reservoir allows the needle and the whole fl owpath cleaning before processing the next sample.
HT1500L comes with HTA Autosampler Manager, HTA complementary software for autosampler programming. After setting the method once, the operator just needs to load samples and presses START: all the samples in the racks will be automatically processed. Seamless integration can also be experienced with the currently used Chromatography Data System.
HT1500L can actually become your workhorse, extremely reliable and straight to the point.
44352pr@reply-direct.com
HPLC Performance Maintenance Kits
Sciencix’s HPLC performance maintenance kits are equivalent to the corresponding OEM kits.
According to the company, the kits contain essential parts to keep HPLC systems performing at an optimal level.
42011pr@reply-direct.com
ADVERTORIAL New and Innovative Chromatography Media
Since 1911 MACHEREY-NAGEL stands for innovation, high quality and reliability in analytical chemistry and life science. MN offers a broad range of products for chromatography, fi ltration, rapid tests, water analysis and bioanalysis as one of today’s leading manufacturers in these fi elds. MN´s expertise in manufacturing of chromatography media is based on many years of experience in silica technology. The development of the spherical HPLC silica NUCLEOSIL®
and the introduction of
commercially available ready-to-use TLC plates and sheets are just two milestones emphasising the pioneering tasks of MN in promoting these separation techniques, which today are omnipresent in analytical labs all over the world.
In September 2017 MN introduced their latest development for solid-phase extraction – CHROMABOND® HLB. This hydrophilic-lipophilic balanced polymeric SPE adsorbent is specially designed for the enrichment
of hydrophilic analytes from polar matrices like water, blood serum or food. With classical C18/C8 modifi ed silica, even with modern hydrophobic polymer adsorbents, retention is often diffi cult. Linked hydrophilic groups of the HLB copolymer interact with polar functional groups of the analytes while the lipophilic backbone interacts with nonpolar hydrocarbon residues to provide enhanced retention. A broad range of columns, cartridges and 96-well plates packed with CHROMABOND®
The latest launches, CHROMABOND® PL for the removal of phospholipids and CHROMABOND®
media. For more information, visit
www.mn-net.com/SPE. The hydrophobic HPLC phase NUCLEODUR®
C18
HLB adsorbent can be applied for a wide range of applications (e.g., pesticides from water, pharmaceuticals from serum, antibiotics from honey). Carbon A for analysing acrylamide in drinking water, complement the steadily growing range of innovative SPE
Gravity-SB with its distinct polar selectivity is ideal for method development, because it shows better retention of early eluting compounds. Overall sophisticated
analytical separations, especially for polar compounds (e.g., antibiotics, water-soluble vitamins, organic acids), are recommended applications. The recently introduced biphenyl phase NUCLEODUR® TT2
separation mode of the HPLC phase is based on two retention mechanisms – TT
In order to meet the growing demands on saving analysis time and solvent costs, MACHEREY-NAGEL expanded the portfolio by adding core-shell silica phases with 2.7 and 5 µm particle size. NUCLEOSHELL®
reversed phase and
HILIC columns enable signifi cantly shorter run times at moderate column back pressures and set new effi ciency standards in research and quality control. For more information, visit
www.mn-net.com/HPLC.
But can thin-layer chromatography be innovative? For about 50 years MACHEREY-NAGEL has been manufacturing glass plates, as well as aluminium and plastic sheets coated with silica gels and other adsorbents for TLC and HPTLC. Until today, the glass plates SIL G-25 with and without UV indicator as well as the ALUGRAM®
Xtra SIL G aluminium sheets
are very important TLC products which are often used in scientifi c laboratories, but also in clinical, pharmaceutical, natural product and food analyses.
Yes, TLC can be innovative. The application of large volumes of very dilute samples can cause irregular spreading of substance spots, which complicates evaluation. The innovative TLC glass plates SILGUR-25 and the aluminium sheets ALUGRAM®
Xtra SILGUR
– silica-coated plates or sheets with a concentrating zone of inactive kieselguhr – solve this problem by concentrating sample spots on the layer.
The latest TLC development, Channel-Plates SILGUR- 25-C UV254
ww.mn-net.com www.mn-net.com
G · Neumann-Neander-Str. 6–8 · 52355 Düren · Deutschland FR:
CH:
9001: 2008 TIFIZIERT
+41 62 388 55 00 +41 62 388 55 05
ail:
sales-ch@mn-net.com
Tel.: +49 24 21 969-0 Fax: +49 24 21 969-199 E-Mail:
info@mn-net.com
A wide range of approved and of new application notes are freely accessible online
www.mn-net.com/apps.
Tel.: +33 388 68 22 68 Fax: +33 388 51 76 88 E-Mail:
sales-fr@mn-net.com
EN ISO 9001: 2008 ZERTIFIZIERT
Tel.: +41 62 388 55 00 Fax: +41 62 388 55 05 E-Mail:
sales-ch@mn-net.com
Tel.: +49 24 21 969-0 Fax: +49 24 21 969-199 E-Mail:
info@mn-net.com
Tel.: +33 388 68 22 68 Fax: +33 388 51 76 88 E-Mail:
sales-fr@mn-net.com
Tel.: +41 62 388 55 00 Fax: +41 62 388 55 05 E-Mail:
sales-ch@mn-net.com
44021pr@reply-direct.com
MACHEREY-NAGEL GmbH & Co. KG · Neumann-Neander-Str. 6–8 · 52355 Düren · Deutschland DE / International:
FR: CH:
with 19 channels, helps to prevent cross contamination by sectioning several samples. More samples can be separated on a plate, and spot areas can be more easily determined. For more information, visit
www.mn-net.com/TLC.
FR: Find what you are looking for! interactions and hydrophobic interactions.
, provides new options to improve selectivity for aromatic and unsaturated compounds (e.g., steroids, sulfonamides, tetracyclines). The innovative -TT
MACHEREY-NAGEL Manufacturer of premium chromatography media
n CHROMABOND® SPE columns
n NUCLEOSIL®, NUCLEODUR® and NUCLEOSHELL® HPLC columns
n TLC plates and sheets
MACHEREY-NAGEL GmbH & Co. KG · Neumann-Neander-Str. 6–8 · 52355 Düren · Deutschland DE / International:
Tel.: +33 388 68 22 68 Fax: +33 388 51 76 88 E-Mail:
sales-fr@mn-net.com
www.mn-net.com
www.mn-net.com www.mn-net.com
7037ad@reply-direct.com
WWW.LABMATE-ONLINE.COM
Chromatography
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48