30 New Sine-Wave Vibro Viscometer SV-A Series


Tired of wasting your expensive sample fluid? The solution is finally here: A&D’s new sine-wave vibro viscometer, the SV-A series. This new viscometer can perform viscosity measurements with a sample as small as 2ml (SV-1A).


Furthermore, unlike conventional viscometers, while maintaining an excellent repeatability of 1% of reading, the SV-A’s tuning- fork vibration method allows for continuous measurements from very low to high viscosity [SV-1A: 0.3~1000mPa•s (cP), SV-10A: 0.3~10000mPa•s (cP), SV-100A: 1000~100000mPa•s (cP)] without changing the sensor plates. The SV-A comes with the standard software set, which realises real-time, simultaneous graph plotting of both viscosity and temperature changes on a PC. This makes it easy to find the cloud point of samples, such as for nonionic surface-active agents.


Circle no. 352 Analytical Balances GH Series/HR-i Series


A&D’s GH series (GH-252, GH-202, GH-300, GH-200, GH-120) is suitable for various analytical weighing applications. The GH- 252 has a dual weighing range and is the leading model in the GH series, with its semi-micro (0.01mg) weighing range up to 101g.


The one-touch calibration function with its motor-driven internal mass enables easy and simple calibration for accurate weighing. The GH series boasts extremely high stability and repeatability. In addition to the existing GR series, the GH series also offers you more flexibility and choice in meeting your 0.01mg and 0.1mg weighing needs. The HR-i series (HR-202i, HR- 300i) has the same body as the GH series, but without the internal calibration mass.


Both the GH series and the HR-i series come with a standard RS-232C interface with WinCT software. For the GH series, a Quick USB interface, which requires no driver installation, and an Ethernet interface with WinCT-Plus software, which allows communication with multiple balances, are also available as options.


Circle no. 353


FX-iWP Series – A&D’s Exclusive IP65 Compliant, Water/Dust Proof Precision (1mg) Balance!


“What if I spill something on the balance?” This question is already a thing of the past. Take a look at the picture, and see what you can do with an IP65 compliant precision balance, available only from A&D. Our precision balance, the FX-iWP, enables you to measure liquid or powder (e.g. pharmaceutical substances) at 1mg resolution while eliminating any worries about damage to the device. Of course, it is equipped with all the functions and benefits offered by the existing FX-i series, such as a B5-size footprint and a stabilisation speed of just 1 second. The FX-iWP can also withstand a variety of adverse conditions. For example, is your workshop filled with oil mist? No problem! Such situations, which may have caused difficulties with precision balances in the past, no longer exist now that the FX-iWP is here.


The FX-iWP series includes six models; the FX-120iWP (122g/1mg), FX-200iWP (220g/1mg), FX-300iWP (320g/1mg), FX-1200iWP (1220g/10mg), FX-2000iWP (2200g/10mg), and the FX-3000iWP (3200g/10mg). Choose whichever model best suits your purposes. The FZ-iWP series is available if you prefer calibration with internal mass.


Circle no. 354


ADVERTORIAL


Moisture Analysers MS-70 / MX-50 / MF-50 / ML-50


The MS-70, MX-50, MF-50 and the ML-50 are moisture analysers that utilise the heating and drying method, which compares the weight of a sample before and after heating and drying. Compared with Karl Fischer analysers, the MS/MX/MF/ML analysers are much easier to operate and require a shorter time for measurements.


Moreover, using WinCT-Moisture software, it is possible to determine the most suitable heating conditions for a given sample in a very short time. The moisture content resolution of the MS, MX, MF and the ML is 0.001%, 0.01%, 0.05% and 0.1% respectively. The MS-70 is the leading model and is capable of measurements as precise as those done by a Karl Fischer moisture analyser.


Circle no. 355


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102  |  Page 103  |  Page 104  |  Page 105  |  Page 106  |  Page 107  |  Page 108  |  Page 109  |  Page 110  |  Page 111  |  Page 112  |  Page 113  |  Page 114  |  Page 115  |  Page 116  |  Page 117  |  Page 118  |  Page 119  |  Page 120  |  Page 121  |  Page 122  |  Page 123  |  Page 124  |  Page 125  |  Page 126  |  Page 127  |  Page 128  |  Page 129  |  Page 130  |  Page 131  |  Page 132  |  Page 133  |  Page 134  |  Page 135  |  Page 136  |  Page 137  |  Page 138  |  Page 139  |  Page 140  |  Page 141  |  Page 142  |  Page 143  |  Page 144