66 INTERIORS


Armstrong Ceilings set to help focus on delivering hundreds of new schools


sector procurement specialist Scape Group shows 640 new schools will be needed over the next two years. In that time an additional 385,000 pupils


W


are expected to join England’s school system, with every region in the country experiencing at least a 3 per cent increase on the current number of pupils. To handle the demand, Scape Group is


asking for focus on delivering a strategy and solutions which not only provide high-quality, modern spaces for teaching and learning but also offer local authorities cost certainty, value for money and timely delivery. But buildings for education are among


those which have particularly onerous design requirements in the areas of acoustics, natural light and fire resistance.


Elements for consideration for the design of ceilings are: 1. Any room will have an optimum reverberation time (RT) requirement depending upon its use and size and whether the main activity is speech or music based. Providing too much sound absorption, and hence having a very low RT, can be just as acoustically damaging and undesirable as having insufficient sound absorption when an excessively long reverberation time will result. Office workers improve their focus on tasks by 48 per cent when speech privacy is improved.


2. You can calculate the reverberation time of space by using a mathematical model based upon the “Sabine” formula which takes into account the significant surfaces of a room, their respective sound absorption coefficients and the room dimensions. An acoustic module available from some manufacturers enables a simple indicative calculation to be made. Once the total sound absorption present in a room (from both planar surfaces and objects) has been calculated, an estimate can be made of the room's probable reverberation time. The installation of clouds and canopies in a reverberant space can significantly reduce the reverberation time and contribute to the reduction in background noise.


ith just a couple of months to go before the start of the summer holidays, latest research by public


3. Fire resistance in a suspended ceiling can only be achieved by a combined tile and grid system as there is no such thing as a fire resistant tile or a fire resistant grid. Depending upon national legislation, the type of structure to be protected (wood, concrete or steel) and a manufacturer’s product offer, ceiling systems can typically provide at least 30 and more than 60 minutes’ protection. Full details of the ceiling type and construction, protected structure and tested time are given in fire reports available from the manufacturer.


4. The increased use of concrete thermal slabs as heat sinks rules out wall-to-wall ceilings. But not having an acoustic ceiling will mean higher reverberation times and unacceptable noise levels. The installation of canopies in a reverberant space, in sufficient numbers and layout to satisfy both technical and aesthetic considerations, can significantly reduce the reverberation time and contribute to the reduction in background noise and occupants’ comfort and well-being.


5. According to a Brinjac Engineering study (2006) on the environmental effect of high-light reflectance ceilings, the use of a 90 per cent light reflectance ceiling tile combined with indirect lighting can provide cost savings of up to 20 per cent, equating to as much as an 11 per cent reduction of the energy buildings use, compared with a standard 75 per cent light reflectance tile. Canopies installed over an


individual working place can improve the light reflection over that space and provide improved user comfort without affecting other areas.


6. Standard ceiling tiles can not only be used to hide or integrate service elements such as lighting fixtures, loudspeakers, air diffusers, chilled beams and sprinkler systems, but provide minimal grid visibility for a clean and monolithic ceiling finish. The system can also be integrated into canopies to offer design solutions for thermal mass and is flexible enough to allow the re-configuring of room layouts and service element positions without moving ceiling panels.


7. It is now possible to calculate (according to ISO 14021) exactly what degree of recycled content a ceiling tile comprises, and recycling schemes such as those for the off-cuts from new installations and end-of-life tiles from refurbishment and strip out projects, both of which divert waste from landfill, will increase this ratio exponentially. Some ceiling tiles comprise more than 70 per cent recycled material and some ceiling systems are capable of achieving an Ecopoints rating of 0.16.


For more information, please email sales-support@armstrong.com.


0800 371849 www.armstrongceilings.com/commercial/en- gb/technical-downloads.html


WWW.ARCHITECTSDATAFILE.CO.UK


ADF MAY 2019


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76