Measurement and Testing
Detecting Sulphur Compound Impurities in Natural Gas, LPG, Propane and Butane The MEDOR®
Exp from Chromatotec® is aimed at online monitoring of sulfur compounds in hazardous zones. This analyser offers continuous analysis and
full speciation of all naturally occurring sulphur compounds such as H2S, Methyl and Ethyl Mercaptan as well as odourant blends, from concentrations as low as 1 ppb.
The system uses proven auto-GC technology for odourisation, quality and safety applications in a wide variety of processes:
Odourisation application: The MEDOR Exp has been developed to monitor all available odourant and mercaptan blends available from all manufacturers. The system can be used to continually analyse and control odourant injection systems for natural and biogas sites.
Pipeline quality control: The analyser is widely used for sulphur content in natural gas storage and transport. Odourless gas can be analysed for natural sulphur species before and during transport or storage.
Process monitoring – gas cleaning & desulphurisation: Sulphur removal processes, such as biogas treatment before injection into a pipeline network, requires careful monitoring and control. With detection limits as low as 1 ppb H2S, the MEDOR Exp system offers users unparalleled security for process monitoring.
The quality and performance of the system has been recognised worldwide by Standard Organisations such as ISO and ASTM. The MEDOR Exp is supplied in a stainless steel purged cabinet. The system is certified ATEX zone 1 and 2, group IIC T4 and CSA (Class 1 Division 2). for hazardous areas.
The Exp cabinet is protected by continuous flow with an X or Z purge system certified for zone 1 and zone 2 respectively. This purging system includes pressure regulator with a flow restrictor to control the inlet dilution. A flow controller is located at the valve outlet to validate the flow out of the cabinet. The cabinet is pressurised and diluted continuously.
IP 66 class allows the use of the unit in waterproof case environment and reduces the instrument air consumption volume needed for the continuous dilution. H2S, mercaptans and total sulfur can be analysed by MEDOR Exp with only nitrogen used for analysis and integrated calibration device.
One of the main advantages of MEDOR is that no additional hazardous area is created in the analyser as it could be the case with hydrogen or air presence and a flame. The worst case is taken into account to calculate the dilution flow to stay under the explosive condition.
If pressure inside the cabinet is not higher than the ambient pressure, the power is switched off by the X-purge system. For service there is a by-pass key to open the cabinet without pressure inside.
Due to these improvements, Chromatotec provides a full analytical solution for natural gas monitoring in hazardous area.
For More Info, email: email:
For More Info, email: email:
41117pr@reply-direct.com
For More Info, email: email:
For More Info, email: email:
New Total Sulfur Process Analyser
Rigaku’s NEX XT is the next generation process gauge for high-level total sulfur measurement (0.02% to 6% S) of crude, bunker fuel, fuel oils, and other highly viscous hydrocarbons, including residuums. This versatile, compact and robust X-ray Transmission / Absorption (XRT / XRA) process gauge is specifically optimised for the total sulfur analysis needs of refineries, pipelines, blending operations, bunkering terminals and other storage facilities. Applications for the NEX XT include bunker fuel blending to meet MARPOL Annex VI sulfur restrictions, interface detection of different grade fuels delivered via pipelines, refinery feedstock blending and monitoring, and the quality monitoring of crude at remote collection and storage facilities.
For More Info, email: email:
For More Info, email: email:
39882pr@reply-direct.com
59
For More Info, email: email:
For More Info, email: email:
35805pr@reply-direct.com
6142ad@reply-direct.com
ANNUAL BUYERS GUIDE 2017 •
WWW.PETRO-ONLINE.COM
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96 |
Page 97 |
Page 98 |
Page 99 |
Page 100 |
Page 101 |
Page 102 |
Page 103 |
Page 104 |
Page 105 |
Page 106 |
Page 107 |
Page 108 |
Page 109 |
Page 110 |
Page 111 |
Page 112 |
Page 113 |
Page 114 |
Page 115 |
Page 116