search.noResults

search.searching

note.createNoteMessage

search.noResults

search.searching

orderForm.title

orderForm.productCode
orderForm.description
orderForm.quantity
orderForm.itemPrice
orderForm.price
orderForm.totalPrice
orderForm.deliveryDetails.billingAddress
orderForm.deliveryDetails.deliveryAddress
orderForm.noItems
Analytical Instrumentation


The speed of ultrafast GCs like the Calidus GC inspired Falcon to author a new ultrafast SimDis method. The Ultrafast ASTM D7798 SIMDIS Method performs simulated distillation nearly six times faster than the equivalent D2887. D7798’s speed enables increased throughput, superior repeatability and reproducibility, tighter control parameters, increased product quality, cost reduction and feedstock conservation.


With improved repeatability and reproducibility, technical staff can spend less time on misleading, analytical variance and more time on true process variance and related product quality analysis. Better control also enables conservation of feedstock, resulting in greener operations all around.


If the user can squeeze more product from the same quantity of feed stock, two things can happen: there is more for someone else to use, or consumption of the valuable and vital resource is reduced. Tighter control also means that process power and other input resources can be conserved with positive consequences for the user and the environment.


Olefin Polymerisation Control


A three-stream ultrafast Calidus system was installed to optimise plant production, specifically to meet product grade specifications without excess processing. Negative financial impacts of excess processing are extra raw material consumption, higher steam consumption and delivery of above spec quality product. With appropriate impurity content the user endures less give away.


Mobile Fuel Fraud Detection


For some time, Illicit fuel providers in the U.K. had been illegally selling low duty fuels intended for agriculture, construction and other approved uses as road fuel. Road fuel is taxed at much higher rate; thus the fraudulent providers avoided paying millions in rightful taxes. The HMRC (Her Majesty’s Revenue and Customs) estimates that illicit market share for diesel is just under 1% in Great Britain and 8% in Northern Ireland. Overall, this represents an annual loss of around £100 million or close to $140 million US dollars in public revenue.


Authorities added markers to the low duty fuels to enable detection when the fuels were sold for road use, but the criminal fuel marketers found ways to remove or “launder” the markers out of the fuel. Recently U.K. and Irish revenue officials adopted a new marker that is more difficult to launder from the low duty fuels, but samples still needed to be transported to labs for testing, creating delays in detection and enforcement.


A Calidus GC system configured to batch process control.


In measurement for process control, whether in batch or continuous processing, time is critical. Timely measurement of process composition is needed for controlling to both product quality and profitability requirements. Over-processing consumes energy, reduces throughput and can negatively impact final product quality. Under-processing reduces yield, increases raw material costs and can negatively impact final product quality.


A Calidus GC Mobile GC System like the one used for HMRC fuel fraud detection.


In the latest HMRC initiative, a high-tech system employing Falcon’s ultrafast Calidus CS GC was installed in a mobile fleet of 49 HMRC road fuel testing unit vehicles throughout the UK and used to analyse fuel samples taken at the roadside and at retail premises.


Three-stream process system in three-sided shelter.


Application requirements included online, representative, repeatable sampling, fast analysis, and full automation from sample tap to the DCS connection. The three-stream system produced excellent resolution with run times of 5 minutes on two streams. The 3rd was optimised at 3 minutes. The system was installed in late March 014. The user has experienced no downtime to date.


The ultrafast GC’s speed, sensitivity and transportability made it a very attractive choice for such an application. Due largely to Falcon’s patented resistively-heated column module the Calidus CS GC cycles 10 to 50 times faster than traditional GCs. Speed was of the essence for the roadside analyses required by the HMRC programme.


In an application where an entire lab is effectively installed in a SUV, the Falcon GC’s small size and weight were also a huge advantage.


Also, the patented Falcon modular GC system design can incorporate two independently temperature-programmed column modules in one analyser to enable more powerful separations. The enabled heartcutting of specific components from one column module to another independent column module delivers separation and sensitivity unattainable with a single dimensional method.


In the application developed for HMRC a single GC configured with two column modules, a column switching heartcut valve and dual FIDs was employed. This design enabled detection of the HMRC fuel marker at a pass/fail level without false positives or false negatives and quantitative analysis down to the 125 ppb limit of quantification.


Falcon now offers mobile GC systems similar to the system employed by the HMRC fuel fraud detection program for other transportable applications.


Batch Process Control A Calidus GC installed in a typical process enclosure.


The user sought to improve batch process control for food grade materials by reducing turnaround time for their GC-based endpoint measurements. Ending batches at reaction completion is optimum.


CALIDUS linearity for this analysis is also extraordinary.


Analytical requirements included seven sample types with sample boiling ranges from about C3 to C50. The ultrafast Calidus system performed the measurements nearly 10 times faster than traditional methods, while meeting all repeatability and reproducibility requirements. Faster analyses meant faster, more optimised production for the user, with sustained or improved product quality and increased opportunities for reducing costs.


Heated Headspace Gas


Falcon Analytical also developed a Calidus headspace unit for the analysis of certain oxides in fatty acids. The GC can quantify these important components in the 500ppb range with excellent repeatability and linearity.


Headspace gas analyses with or without heat is important to many users. The application shown here is just the first. Falcon expects to do analysis for residual monomer in polymeric products, residual solvents and even sparging water and wastewater for contaminants or pollutants. Trapping technology will also be deployed to produce a fully functioning purge and trap GC system.


35


CALIDUS delivers these measurements with excellent repeatability.


Author Contact Details Rod Carter. Falcon Analytical • 433 AEI Drive, Lewisburg, West Virginia, USA • Tel: (304) 647-5860 Fax: (304) 647-3743 • Email: info@falconfast.netwww.falconfast.net


ANNUAL BUYERS GUIDE 2017 • WWW.PETRO-ONLINE.COM


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102  |  Page 103  |  Page 104  |  Page 105  |  Page 106  |  Page 107  |  Page 108  |  Page 109  |  Page 110  |  Page 111  |  Page 112  |  Page 113  |  Page 114  |  Page 115  |  Page 116