level of stability required for installations which may include high-sided splits or VRF units. So what is the answer? An economical solution to these installation headaches is to use non-penetrative, repeatable support structures mounted on anti-vibration mats. These structures are configurable in that they can be adjusted according to the demands of each individual project. Designed to meet the changing needs of a building the supports can easily be moved or adapted to fit new requirements, allowing building owners to easily make further upgrades to plant as needed.


For example, Big Foot Systems’ light duty range is non-penetrative, quick to install, robust and offers an array of solutions to support a variety of air handling units and air conditioning systems. Frame kits for most major manufacturer’s VRF units are available from stock. These will suit most applications including extract and supply fans, air conditioning, VRF units and air handling units. These non-penetrative support systems, in the form of frameworks that are wider than the unit they are supporting, afford a greater degree of protection against tipping. To determine the correct frame for an installation Big Foot runs calculations that consider the cumulative


weight of the supported unit, roof capability, whether the installation is wind protected or not and Meteorological Office information relating to local peak wind speed. These calculations establish the size of frame required to prevent plant tipping, and the number and size of foot bases in contact with the roof needed to ensure the cumulative weight is dispersed evenly over the roof area and is within workable loads of the roof build up, which improves safety for the service engineer and pedestrians below.


Problems with resistances caused by the vertical surface area are also dealt with by these support frames. For example, when split air conditioning units are arranged on roof supports, the frames allow them to be installed with a one metre distance between each split unit, securing them firmly in a uniform manner. This results in a high degree of stability in strong winds. The plant is also clamped to the supports giving it further stability. Maintenance is easier with these innovative frameworks because the supports raise the AC units above the flat roof making them more accessible and creating space to run pipes. Suitable for both new build installations and retrofitting non-penetrative systems are quick and easy to install ensuring project cost and time clarity, negating a need for time consuming and costly penetrations through the roof.


S R W 2 Way R410 Manifold Set


Front wheel R410 manifold set complete with 60 " hoses and case


A real bargain at just £49.00


Service and Maintenance 31


Nitrogen Regulators


Top quality twin gauge 50 bar single stage nitrogen regulator for pressure testing etc. of systems including R410 connection.


Vacuum Pumps


Robinair 15401 3.33 cfm £289.00 15601 5 cfm £309.00 15121 8 cfm £695.00


Mastercool 90060 1.25 cfm £159.00 90063 3cfm £149.00 90065 4.2 cfm £229.00 90067 6.3 cfm £269.00 90070 7 cfm £289.00


SRW Recovery Machines


Mastercool 69300 twin turbo £575.00 69300 dual voltage £620.00 69000 69200


£595.00 £649.00


Promax RG3000 Mini max


£549.00 £629.00


RG5410 extreme £960.00 all above available in 240 or 110v


Digital Vacuum Gauge


Mastercool 98061 high accuracy digital vacuum gauge with thermister head.


Range : 20,000 - 1 micron Display :Micron, Torr, mTorr, mmHg, mBar, or Pa


Clear indication reads in 1 degree steps across full range.


01273 455530 Fax 01273 455575


SRW Unit 4, Harbour Way Shoreham by Sea


West Sussex BN43 5HG Visit ACR News online at www.acr-news.com


Ring for your free Buyers Guide


Credit card orders welcome Delivery free on all orders over £50 prices exclude v.a.t. E&O.E.


WWW.SRW.CO.UK ACR News May 2014


only


£49


£149.50


from


£149 from £549


£129.75


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68