E RS-232 Hi-Precision Balances


From £340.00


Ring draft


Stainless Steel Weighing Pan 160 x 200mm


UYKT-01


shield supplied with 105mm weighing pan


Glass draft shield with 3 sliding doors: Left, right & top. Model M572-A05


UYKB-01


These multi-function precision balances are robust and sturdy with a metal housing, Stainless Steel weighing pan, backlit display and membrane touch-type keypad. These balances are ideal for laboratory environments with high resolution, RS-232 interface, user calibration and GLP facilities.


• User selectable weighing units including g, Kg, oz, lb, ct, dwt & gn


• Metal housing with Stainless Steel weighing pan


• 18mm LCD display with Backlight and function indicators


• Step-by-step menu-driven user guidance on the display


• Tare function can be repeated throughout the weighing process


• Auto-Tare function stabilises zero point. Returns display to zero if there are minor changes in weight – user enabled/disabled


• Net Total Weighing - weight of a tared container and the weight of components can be memorised in 2 separate memories


• Percentage Determination displays any deviation from the reference weight in % instead of grams


• Plus/Minus weighing – weight is displayed as a plus or minus value against a set target weight


• Under Scale weighing


• User programmable for special weighing units e.g. thread length in g/m, paper weight in g/m² or similar


• Parts Counting from samples of 1, 5, 10, 20 & 50 parts


• Auto optimisation of the reference weight for precise counting


54 01530 566800 F


• Auto Power Off after 3 minutes of no activity


• Comply with Good Laboratory Practice (GLP) – only with statistics printer (YKT-01)


• RS-232 interface for data transfer to a printer, PC or laptop (572- 926 & SCE-3.0)


• Optional glass draft shield 572- A05, available for use with models U572-30, U572-31 & U572-32. Weighing space is 150 x 140 x 130mm, with 3 glass sliding doors


• Optional external rechargeable battery KS-A01 available. Operating time approx 50hrs, charging time approx 10hrs


• Supplied with an AC/DC mains power adaptor and protective cover. U572-30, U572-31 & U572-32 also supplied with 160mm Ø x 60mm ring-shaped coated metal draft shield


Calibration Certificate Issued at 5 points:


15%, 30%, 45%, 60% & 75% of capacity


Additional points at: £10.00 per point


TECHNICAL SPECIFICATIONS U572-30


Range


Resolution Accuracy


241g 0.001g ±0.003g


Min PCs Wt 0.001g Pan Size


Range


Resolution Accuracy


Ø105mm U572-35 2,410g 0.01g


±0.03g


Min PCs Wt 0.01g Pan Size


Range


Resolution Accuracy


Ø150mm U572-49 16,100g 0.1g


±0.3g


Min PCs Wt 0.1g Pan Size


4Kg


U572-31 301g


0.001g


±0.003g 0.001g


U572-32 421g


0.001g


±0.003g 0.001g


±0.03g 0.01g


U572-43 10,100g 0.1g ±0.3 0.1g


U572-33 1,610g 0.01g


±0.03g 0.01g


Ø105mm Ø105mm Ø150mm U572-37 3,010g 0.01g


U572-45 12,100g 0.05g


±0.15g 0.05g


Ø150mm 160 x 200mm 160 x 200mm U572-55 20,100g 0.05g


U572-57 24,100g 0.1g


±0.15g 0.05g


Dimensions 310 x 180 x 90mm Weight


Model No. Description U572-30


U572-31 U572-32 U572-33 U572-35 U572-37 U572-45 U572-49 U572-55 U572-57 CAL-SC 572-A05 KS-A01 YKT-01 572-926 SCE-3.0


01530 560373 Price


161g x 0.001g Precision Balance 241g x 0.001g Precision Balance 421g x 0.001g Precision Balance 1,610g x 0.01g Precision Balance 2,410g x 0.01g Precision Balance 3,010g x 0.01g Precision Balance 12,100g x 0.05g Precision Balance 16,100g x 0.1g Precision Balance 20,100g x 0.05g Precision Balance 24,100g x 0.1g Precision Balance Traceable Calibration Certificate Glass Draft Shield


External Rechargeable Battery Pack Statistics Printer (Without Cable)


RS-232 Printer/PC Connection Cable (1.5m) “Balance Connection” Software


£360.00 £370.00 £395.00 £340.00 £350.00 £360.00 £360.00 £340.00 £395.00 £360.00 £60.00


£150.00 £155.00 £750.00 £42.50 FOC


www.atp-instrumentation.co.uk


±0.3g 0.3g


160 x 200mm 160 x 200mm 160 x 200mm


N


W


R


D


A


E


N


G


E


A


S


A


D


D


E


A


D


R





N


E


W


N


G


E


S


D


D





Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102  |  Page 103  |  Page 104  |  Page 105  |  Page 106  |  Page 107  |  Page 108  |  Page 109  |  Page 110  |  Page 111  |  Page 112  |  Page 113  |  Page 114