Product name - pump type - split or mono - output range - maxium SCOP - MCS accredited - size (mm) •
Geoclima/Hecoclima R1234ze commercial industrial heat pump – Air and Water source heat pump / Monobloc / 12kW to 500kW / 4.5+:1 / Not MCS accredited / size is capacity dependant.
Installation aids av ailable • • •
Mounting kits
Ancillary pipework Control valves
CaseStudy
Heat pumps (air and water source) are going to be without doubt the future of space and water heating in the UK as the world moves to decarbonise. Heat pumps are nothing new and DX, VRV and VRF systems have been pulling heat from thin air for decades now, however they are best suited to smaller scale applications and until recent years the larger scale air source heat pump with capacities above 250kW
W were a rare item of plant.
The challenge for air source heat pumps (ASHP) has always been producing the higher water temperatures required for them to replace gas boiler plant, especially in lower ambient temperatures particularly below freezing.
CO2 refrigerant systems do offer a solution that can deliver very high- water temperatures of 90°C+, but they typically need a return water temperature back to the unit of below 40°C which leads to a (difficult to apply) wide ∆T°K across the heating circuit, or the need to add supplementary heat rejection to bring the return water temperature below this limit which in turn erodes system efficiencies.
With the global push to move away from refrigerants with a high GWP R410a has stopped being the mainstay of heat pump technology and many alternatives have been developed.
HFO R1234ZE has been Cooltherm’s ultra-green alternative to R134a for the last few years when suppling industrial water chillers, however it would also transpire that R1234ZE’s wide enthalpy envelop lends itself well to the application of ASHP’s.
There are many advantages of opting to install a R1234ZE heat pump over alternatives such as CO2 if an operating leaving temperature of 75°C
or less is required; these benefits include significantly lower operating pressures, non-specialist fabrication of the plants internal components and maintenance thereof, and the capital cost of the ASHP is much lower than CO2.
Cooltherm working with Geoclima have developed a full range of ASHP’s up to 500kW that can deliver reliably full duty at typically -5°C
HEA
AT PUMP GUIDE
Address: Unit 5 Trubody’s Yard, 121 London Rd, Bridgeyate, Bristol, BS30 5NA Tel:
info@cooltherm.co.uk www.cooltherm.co.uk
Controls Available • • • •
Weather compensation
Cascade control System monitoring Integrating controls
Other products av ailable • •
Mission Statement
Mission Statement •
Quality in everything we do.
Heating and cooling systems Electric heating modules
Unique selling points • • • •
Full Design
Turnkey installation Commissioning
Service and Maintenance through the life cycle.
Brief compan y history • • • •
Country of origin: UK Founded in: 1992
Group turnover: 60+ million Number of employees in the UK: 81
ambient with 87% rh (and partial duty down to -10°C) with leaving water temperatures up to 70°C. At this condition these units deliver an EER of 2:1 and in typical UK winter ambient conditions this rises to over 3.5:1. The Cooltherm team has just completed the handover of two inverter driven reciprocating compressor ASHP’s which have been combined with matched high efficiency Air Handling Units for a UK Nuclear research establishment, these units also have an exceptionally low noise level of 50.8 dB(A). Moving forward R1234ZE is a real alternative to boilers providing hot water within the UK’s building stock.
www.heatingandventilating.net
March 2020
33
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56