OPERATION & MAINTENANCE OF POWER PLANTS
T
here are several flue gas treatment methods that can be applied to reduce pollutant emissions to air from combustion-based power generation.
Gas concentration monitors are often used to control and protect the reduction processes. Tis article describes some common reduction methods and highlights a suitable gas monitoring technique. Combustion processes can give rise to
a variety of pollutants that are bad for the environment and therefore often regulated when it comes to allowed emissions to air. Te types of pollutants can vary depending on fuel and incineration process. However, some types of pollutants are essentially generic and seen in most combustion-based power generation facilities. Tis applies to dust, sulfur dioxide (SO2
) and some other acidifying gases, and nitrogen oxides (NOX ).
Similar techniques are used to reduce the emissions of these types of pollutants. Tere are also other types of pollutants that may be of concern in specific types of combustion processes. By example, mercury and bromides might be emitted when incinerating hazardous waste.
EMISSIONS REDUCTION METHODS
A generic flue gas treatment process consists of three different subprocesses. First, there is usually a filter used to reduce the dust levels. Ten comes a scrubber
which removes acidifying gases such as SO2 (therefore often referred to as a “DeSOx” stage) and further reduces the dust levels, and finally there is a selective catalytic reduction (SCR, the “DeNOx” stage) stage, which reduces the NOX
levels.
Filters for dust reduction can be cyclones, fabric collectors, and/or electrostatic filters. Tere are also some different types of scrubbers. In a dry scrubbing process, a solid substance such as lime is added to the flue gas. Te lime reacts with the gases and forms solid particles that can be separated in subsequent dust filters. In a wet scrubber, the flue gas is sprayed with water or a neutralising agent. Water-soluble pollutants are then removed from the flue gas and the wastewater is neutralised. Semi-dry processes can also be applied. In the SCR process, NOX react with ammonia (NH3
is forced to ) to form nitrogen
and water. Te reaction is facilitated by using a catalyst that consists of a ceramic carrier covered with rare metal oxides typically based on vanadium, molybdenum or tungsten.
Layout of an Opsis LD500 laser diode-based gas monitoring system, in this case surveying two different flue gas ducts using an optical multiplexer
In some cases, other pollutants can also be caught by either of these treatment processes. Sometimes more specialised methods must be applied, for example the injection of activated carbon to reduce mercury emissions.
MONITORING NEEDS Te SCR process is an example of where there are needs for gas concentration monitoring. Te NOX
levels before
and after the SCR unit are usually measured to give control signals to the NH3
the SCR unit can also be measured to reveal slip and give further feedback to the injection. To protect the catalyst, the levels of SO2
injection. Te NH3 and other acidifying
gases prior to the SCR unit are often also monitored and the signals are used to control the preceding injection of the scrubber agent, and as a last resort to apply an SCR bypass to avoid damage to the catalyst. In either case, the needs require
instruments operating in hot and aggressive gas mixtures, and with very short response times to facilitate the control loops. Tis can be readily achieved with instruments measuring directly in the flue gas (“in-situ”) where no sampling lines can delay the analysis, and notably with laser diode-based units providing high-precision results with time resolution down to a few seconds or better.
level after
An example of such an instrument is the Opsis LD500 gas monitor. Te central unit contains a narrow-band laser whose wavelength is scanned across an absorption line of the molecule to be monitored. Te laser light is led via an optical fibre to an emitter situated on the duct. Te laser light is directed through the flue gases inside the duct and then picked up by a sensor inside a receiver. Data from the sensor is sent back via another optical fibre to the central unit, where the signal is analysed, and the gas concentration can be calculated and fed to the control system. Each molecule type requires its
OPERATING PRINCIPLE OF A LASER-DIODE BASED GAS MONITOR
own laser, but the central unit can be equipped with up to four laser heads, allowing concurrent monitoring of multiple gases. Light multiplexing enables a single unit to monitor the same gas type at several locations. Further, the optical fibres can be made very long, giving additional flexibility to the monitoring system. All in all, this forms a very cost-efficient solution to the needs of an SCR monitor.
Bengt Löfstedt is with Opsis.
www.opsis.se
www.engineerlive.com 17
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52